Dimension

Dimension

MOUNTING CONFIGURATIONS

*Mounting hardware not supplied by Coolon. Please refer to the drawings on page 2 for sizing and mounting footprint.

Horizontal Plane

Mount the XBLADE™ using a minimum of:
8 x M16 Grade A4 Stainless (316) bolts OR
8 x M16 grade 8.8 galvanised High Tensile Steel bolts

Horizontal Plane – Suspended

Mount the XBLADE™ using a minimum of:
8 x M16 Grade A4 Stainless (316) bolts OR
8 x M16 grade 8.8 galvanised High Tensile Steel bolts

Vertical Plane

A beam coupling plate must be used to provide structural integrity along the length of the XBLADE™ mounting bracket in applications where the entire bracket cannot be fastened to a surface.
Mount the XBLADE™ and Beam Coupling Plate using 8 x M16 bolts and nuts*
MOUNTING CONFIGURATIONS

NOTE: XBLADE™ can rotate 360º. Please be aware of the power cable’s position with respect to the angle of the luminaire, avoid cable damage due to excessive bending. When using the locking/securing screws 1 screw per side will be sufficient however some angles allow for an additional screw if desired.

Configuration A
Configuration

Configuration B
Configuration

Mounting Bracket
Mounting Bracket

Beam Coupling Plate (Optional Accessory)

ACC-BCP-BC400-PL330-MS
Beam Coupling Plate

SIZING AND SPACING

Remote Power Supply
Remote Power Supply

CONNECTION – MAINS

Open the junction box by rotating the lid counter-clockwise

230VAC
CONNECTION - MAINS

415VAC DELTA
CONNECTION - MAINS
415VAC nominal input voltage
Use any 2 phases and connect to A and N

Once the product has reached end of life, unit is to be disposed of in accordance to local e-waste laws or regulations. Do not dispose of these products as unsorted municipal waste: take them for recycling.
For information on your nearest recycling point, check with your local waste authority

CONNECTION – RPS

Remove the junction box lid (4 x M6 SEMS Captive Screws) and connect wires from power supplies as per the diagram below.
NOTE: No Polarity Protection. Observe correct DC polarity between power supply and luminaire. Cable glands not included. Size: M25x1.5.
Cable gland with strain relief is recommended.
CONNECTION - RPS

Kit Configuration (230VAC)

Kit Configuration

Kit Configuration (415VAC DELTA)

Kit Configuration

support@coolon.com.au
aus. 1300 287 533
intl. +613 8681 3633
www.coolon.com.au
www.coolon.com.au

Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Refer to our website for the latest information

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals