COOLON XBLADE Industrial LED Instruction Manual
- June 12, 2024
- COOLON
Table of Contents
COOLON XBLADE Industrial LED Instruction Manual
Dimension
MOUNTING CONFIGURATIONS
*Mounting hardware not supplied by Coolon. Please refer to the drawings on page 2 for sizing and mounting footprint.
Horizontal Plane
Mount the XBLADE™ using a minimum of:
8 x M16 Grade A4 Stainless (316) bolts OR
8 x M16 grade 8.8 galvanised High Tensile Steel bolts
Horizontal Plane – Suspended
Mount the XBLADE™ using a minimum of:
8 x M16 Grade A4 Stainless (316) bolts OR
8 x M16 grade 8.8 galvanised High Tensile Steel bolts
Vertical Plane
A beam coupling plate must be used to provide structural integrity along the
length of the XBLADE™ mounting bracket in applications where the entire
bracket cannot be fastened to a surface.
Mount the XBLADE™ and Beam Coupling Plate using 8 x M16 bolts and nuts*
NOTE: XBLADE™ can rotate 360º. Please be aware of the power cable’s position with respect to the angle of the luminaire, avoid cable damage due to excessive bending. When using the locking/securing screws 1 screw per side will be sufficient however some angles allow for an additional screw if desired.
Configuration A
Configuration B
Mounting Bracket
Beam Coupling Plate (Optional Accessory)
ACC-BCP-BC400-PL330-MS
SIZING AND SPACING
Remote Power Supply
CONNECTION – MAINS
Open the junction box by rotating the lid counter-clockwise
230VAC
415VAC DELTA
415VAC nominal input voltage
Use any 2 phases and connect to A and N
Once the product has reached end of life, unit is to be disposed of in
accordance to local e-waste laws or regulations. Do not dispose of these
products as unsorted municipal waste: take them for recycling.
For information on your nearest recycling point, check with your local waste
authority
CONNECTION – RPS
Remove the junction box lid (4 x M6 SEMS Captive Screws) and connect wires
from power supplies as per the diagram below.
NOTE: No Polarity Protection. Observe correct DC polarity between power
supply and luminaire. Cable glands not included. Size: M25x1.5.
Cable gland with strain relief is recommended.
Kit Configuration (230VAC)
Kit Configuration (415VAC DELTA)