olympia electronics GRL-22 Emergency Light User Manual

June 12, 2024
olympia electronics

olympia electronics GRL-22 Emergency Light

Product Information

The GRL-22 “POWER LIGHT” Series Non-Maintained Emergency Luminaire is a lighting device designed for emergency situations. It is equipped with a 12V/7Ah lead-acid battery for power backup. The luminaire operates at an input voltage of 220-240V AC with a frequency of 50-60Hz. It has a maximum power consumption of 16VA. The battery is protected from overcharge and deep discharge to ensure its longevity. The luminaire features several indicators and controls for easy monitoring. It has a power indicator to show the status of the main power supply, a battery charge indicator to display the battery level, and a TEST button for performing system checks. Please refer to page 2 for detailed specifications of the LED module used in this luminaire.

Product Usage Instructions

  1. Installation: Follow the installation guidelines provided in the user manual to mount the luminaire securely. Ensure proper wiring connections according to local electrical standards.
  2. Charging: Connect the luminaire to a 220-240V AC power supply. The battery will automatically start charging. The battery charge indicator will show the progress of the charging process. Allow sufficient time for the battery to reach full charge.
  3. Testing: Press the TEST button to simulate an emergency situation and check the functionality of the luminaire. Verify that the power indicator illuminates, indicating the main power supply is working. Also, ensure that the luminaire provides adequate illumination during the test.
  4. Usage: In case of a power failure or emergency situation, the GRL-22 “POWER LIGHT” luminaire will automatically switch to battery mode and provide illumination. Ensure the luminaire is properly positioned to effectively light up the desired area during such situations.
  5. Maintenance: Regularly check the battery charge indicator to ensure the battery is adequately charged. If the battery charge level drops significantly, connect the luminaire to the power supply for charging. Clean the luminaire and LED module periodically to remove dust and ensure optimal performance.
  6. Safety Precautions: Read and follow all safety instructions provided in the user manual. Do not open the luminaire or attempt to repair it yourself. Contact a qualified technician for any repairs or maintenance.

For more detailed information and troubleshooting, please refer to the complete user manual.

TECHNICAL CHARACTERISTICS

TECHNICAL CHARACTERISTICS

OPERATION VOLTAGE| 220-240V AC/50-60Hz
MAXIMUM POWER CONSUMPTION| 16VA
BATTERY (Pb)| 12V/7Ah
BATTERY PROTECTION| From overcharge and deep discharge
INDICATIONS – CONTROLS| Power indicator, battery charge indicator, TEST button
CHARGING TIME| <24h
MINIMUM AUTONOMOUS DURATION| 600 min
LIGHT SOURCE| White LEDs
EMERGENCY ILLUMINATION| 710lm
DEGREES OF COVER PROTECTION| IP42
PRODUCED IN ACCORDANCE WITH| EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
OPERATION TEMPERATURE RANGE| 5 to 40 o C
RELATIVE HUMIDITY| Up to 95%
CONSTRUCTION MATERIALS| ABS/PC, PC
EXTERNAL DIMENSIONS| 302 x 103 x 230 mm
TYPICAL WEIGHT| 3400gr.
GUARANTEE| 3 years (1 year for the battery)

Thank you for your trust in our products Olympia Electronics – European manufacturer

GENERAL

These luminaires are used indoors (ta 40oC) where emergency light is needed. Each luminaire must be permanently connected to mains power supply. In normal operation the power and charge indicators are on to indicate that the batteries are charging. In case of a mains power supply failure the power and the charge indicators turns off and the uminaire will light the spot lamps automatically in emergency mode. When the mains power supply is restored the device turns to normal operation.

INSTALLATION

To install the luminaire follow the installation instructions οn page 3.

OPERATION
When the device is powered from the mains and the battery(ies) is (are) connected, the ‘power’ and ‘charge’ indicators are ON. The ‘charge’ indicator indicates the battery charging operation. If it does not light, probably, the batteries are disconnected. If it does not light and the batteries are connected, then contact the technician. The power indicator confirms the proper connection to the mains. The TEST button, has a dual use. If pressed instantlly while the device is connected to the mains, the device simulates the power interruption, by lighting the lamps for 3”. In that way, we can control the driver circuit of the lamps and the lamps as indicated in paragraph 3 in the text below.

DIMMING OPTION
When the luminaire is in emergency mode, with corresponding pressings of the button, we can choose the illumination of 100%, 50%, 33% or turned off, in order to increase the autonomy duration. This option is canceled when the network is restored.

ΑΤΤΕΝΤΙΟΝ!!!

  1. Operations for installation, maintainance or testing must be done by authorized personnel only.
  2. The device must be connected to the mains power supply through a fuse dependent by the total amount of the line’s power load.
  3. It is suggested to check every month the indication LED for battery charging, and by pushing instantly the TEST button to check the emergency circuit and the lamps. If the luminaire does not light, contact the installer.
  4. It is suggested to check every 6 months the minimum autonomy duration by disconnecting the mains power supply. Count the time that the lamps light and in case of less time than the minimum autonomy duration the batteries must be replaced. If the measured time is considerably less than the minimum autonomy duration contact the installer. The replacement of the battery and the light source must be done using parts of the same type, by the manufacturer or by a competent person.
  5. In case of inactive use for a period greater than 2 months, disconnect the battery by pulling out the battery’s connector.
  6. It is not allowed to discard batteries in to common trash bins, they must be discarded only in battery recycling points. Do not incinerate.

NOTE: LED= Light Emitting Diode

LABELING EXPLANATION:

  • X: Self contained
  • 0: Non Maintained (*)
  • A: Including test device
  • G: Internally illuminated
  • 600: 10 hours duration

*() Non Maintained operation: The luminaire lights its illumination source, only in power supply’s failure.
Note!!** The installer should fill in, on the specification label, the letter G if the luminaire is used as a safety sign.

INDICATION LED STATUS

(with the mains power supply connected)

olympia-electronics-GRL-22-Emergency-Light-1

The light source of this luminaire is not replaceable when the light source reaches its end of life the whole luminaire shall be replaced.

ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ LED

ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ LED

 | GRL-22
Manufacturer| Olympia Electronics Α.Ε.
Model Number| 3011129
Voltage Range| 20.3-25.2V
Nominal Power| 5.46W
Connections| Cable connection between main pcb and led module
Temperature (tc)| 50 °C max. across the board

INSTALLATION PROCEDURE

(For wall mounting only) olympia-electronics-GRL-22-Emergency-
Light-2

  1. Install the included mounting accessories to hook the device from the mounting holes (fig. 1).
  2. Unfasten the 4 mounting screws to remove the front plastic cover (fig. 1).
  3. Make sure that the battery’s cables are connected to the respective poles. Black cable to (-) pole and red cable to (+) pole.
  4. Install the included cable gland or the rubber o-ring. Pass thru the mains cable and stabilize it by fastening the cable gland. Connect the wires to the terminal blocks L for live wire and Ν for neutral.
  5. Refit with care the front plastic cover, by fastening the 4 mounting screws (tightening torque 1Nm).

WARNING!!
After the installation has finished, charge the batteries for at least 24 hours so as to obtain the rated autonomous duration.

Battery replacement
It can be done only by a competent person and after the mains interruption.

  1. Follow the step 2 of the installation procedure.
  2. Disconnect the cables and remove the old battery.
  3. Connect the new battery with the same type (step 3 of the installation procedure) and place it in the position of the old one.
  4. Follow the step 5 of the installation procedure and power on the device.

WARRANTY

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid. Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr