Product Information:
- Product Name: S-531/1 Sounder with Beacon for Fire Detection Panel
- Manufacturer: Olympia Electronics
- Operation Voltage: 21-28V DC
- Maximum Consumption: 1.2W
- Maximum Sound Output: 94dB (sound effect 1) at 1m
- Beacon Type: 1 Power LED
- Type of Application: Fire Detection Panel
- Environment: Indoor
- Mounting: Wall Mounted (W)
- Coverage (y): Up to 6m
- Mounting Height (x): Up to 2.4m
- Coverage Volume Code: Red
- Coverage Volume Flash Rate: 0.5 Hz (0.1 sec ON, 1.9 sec OFF)
- Coverage Volume Flash Colour: Red
- Degrees of Cover Protection: IP42C
- Produced in accordance with: EN 54-3: 2001 +1:2002 +2:2006, EN 54-23: 2010
- Operation Temperature Range: 0 to 60 oC
- Relative Humidity: Up to 95%
- Construction Material: ABS/PC, PC
- External Dimensions: 141 x 141 x 100 mm
- Typical Weight: 230gr.
- Guarantee: 2 years
Product Usage Instructions
- After finishing the installation, place the SEAL sticker as shown in the picture.
- Connect the Fire Detection Panel to +N1 using the DSW (Dipswitch) settings mentioned in Table 2.
- Connect the Fire Detection Panel to +N2 using the DSW (Dipswitch) settings mentioned in Table 3.
- Ensure that the horizontal line on the base is parallel with the ceiling when positioning the device.
ΒS-531/1
SOUNDER WITH BEACON FOR FIRE DETECTION PANEL
ΤΕCHNICAL CHARACTERISTICS
OPERATION VOLTAGE | 21-28V DC |
---|---|
MAXIMUM CONSUMPTION | 1.2W |
MAXIMUM SOUND OUTPUT in1m | 94dB (sound effect 1) |
BEACON | 1 Power LED |
ΤYPE OF APPLICATION ENVIRONMENT | Τype Α |
MOUNTING | Wall |
COVERAGE (y) | 6 m around the siren at an angle of 180° |
MOUNTING HEIGHT (x) | 2.4m max |
COVERAGE VOLUME CODE | W-2.4-6 |
COVERAGE VOLUME | 86.4m³ (max) |
FLASH RATE | 1 Hz (Switchable to 0.5 Hz) |
FLASH COLOUR | Red |
DEGREES OF COVER PROTECTION | IP42C |
PRODUCED IN ACCORDANCE WITH | EN 54-3: 2001 +Α1:2002 +Α2:2006, EN 54-23: 2010 |
OPERATION TEMPERATURE RANGE | 0 to 60 o C |
RELATIVE HUMIDITY | Up to 95% |
CONSTRUCTION MATERIAL | ABS/PC, PC |
EXTERNAL DIMENSIONS | 141 x 141 x 100 mm |
TYPICAL WEIGHT | 230gr. |
GUARANTEE | 2 years |
Thank you for your trust in our products Olympia Electronics – European manufacturer
GENERAL
This device is Visual Alarm Devices (VAD) for fire detection panels that offer
a strong sound output and an optical warning with a beacon. The strong sound
and the optical warning beacon cover many square metres. It features two
inputs (N1, N2) for the production of two different sounds. This device can
cooperate with any fire detection panel (BSR-2104, BSR-2114, BS-1632, BS-1634,
BS-1636, BS-636).
Installation and Connection
- First, remove the retaining screw, place a flat-blade screwdriver in the holes of the plastic hooks and remove the plastic cover (Image 1 on page 2).
- Remove carefully the beacon connector (Image 2 on page 2).
- Use the supplied mounting parts to install the siren’s base at a height of 2.4 metres from the floor (figure 1 on page 2). Place the plastic plugs and fasten the screws to the mounting holes. Attention!! Make sure that the siren’s base is installed upwards as shown in figure on page 4.
- Place the caps and make a hole in the center using a small screwdriver. Pass through the caps the cables to connect the device.
- The (+N1 or the +N2) terminal block is connected to the (+) output of Alarm-1 or Alarm-2 of the panel and the (-) of the terminal block is connected to the (-) output of Alarm-1 or Alarm-2 of the panel. Accordingly connect in parallel all the sirens. (The maximum number of sirens depends on the type of panel).
- To select various sound effects use the dipswitch 1, 2 and 3 and choose the diserable sound effect, according to tables 2 and 3 on page 3.
- For LED effect variation use the dipswitch 4 (Table 1) on page 2. On the last siren of the line, we must connect in parallel with its power cables, the terminal resistor that was removed from the alarm contacts of the panel.
- Reinstall the beacon connector (step 2). Refit the plastic cover until the plastic hooks are securely attached (step 1) and fasten the retaining screw (torque 0.6Nm). Attention!!Make sure that the siren’s cover is installed in the correct orientation.
- Test the device after installation.
NOTE! After finishing the installation, place the SEAL sticker as shown in the picture.
TABLE 2
Fire Detection Panel connection to +N1
TABLE 3
Fire Detection Panel connection to +N2
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid. Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
Certification
The sounder with beacon BS-531/1 is certified from DEDAL. Also DEDAL controls
the production under CPR number:
Figure which shows the correct positioning of the base
Horizontal line parallel with the ceiling
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>