MEAN WELL 600W Ultra-High Peak Power Supply Instructions
Symbol
Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Up to 350% peak power capability
- Built-in constant current limiting circuit
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
- Withstand 5G vibration
- Oprating ) altitude ! up to 5000 meters(Note.5)
- Output votage adjustable +15%(Avg.)
- 5 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment
GTIN CODE
https://www.meanwell.comsenice.GTIN.spx
Description
HRP-600N3 series is a 600W single output AC/DC ultra-high peak power supply.
This series operates at
85~264VAC input voltage and offers the models with the DC output mostly
demanded from the industry. Each model is cooled by the built-in fan with fan
ON-OFF control, working for the temperature up to 70°C. Moreover, HRP-600N3
can provide 350% short-duration peak power for motor applications and
electromechanical loads requiring much higher power during start-up.
Model Encoding
SPECIFICATION
MODEL| HRP-600N3-12| HRP-600N3-24| HRP-600N3-36| HRP-
600N3-48
---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 53A| 27A| 17.5A| 13A
CURRENT RANGE| 0 ~ 53A| 0 ~ 27A| 0 ~ 17.5A| 0 ~ 13A
RATED POWER| 636W| 648W| 630W| 624W
RIPPLE & NOISE (max.) **Note.2| 200mVp-p| 150mVp-p| 200mVp-p| 240mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 13.8V| 21.6 ~ 28.8V| 28.8 ~ 39.6V| 40.8 ~
55.2V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.3%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at
full load
HOLD UP TIME (Typ.)| 16ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.4| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.94/230VAC PF>0.98/115VAC at full
load
EFFICIENCY (Typ.)| 88%| 88%| 89%| 89%
AC CURRENT (Typ.)| 7.6A/115VAC 3.6A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC 70A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
****PROTECTION| ****OVERLOAD| Output power >105% rated for more
than 5 seconds then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >380% rated for more than 5 seconds
and then shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 14.4 ~ 16.8V| 30 ~ 34.8V| 41.4 ~ 48.6V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION| DC OK SIGNAL| PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0
~ 1V
FAN CONTROL (Typ.)| Load 35±15% or RTH2≧50℃ Fan on
****ENVIRONMENT| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating
Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.5| 5000 meters
****SAFETY & EMC (Note 6)| SAFETY STANDARDS|
UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
****EMC EMISSION| Parameter| Standard| Test Level /
Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
****EMC IMMUNITY| BS EN/EN55035 , BS EN/EN61000-6-2(BS
EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field| BS EN/EN61000-4-3| Level 3, 10V/m
EFT/ Burst| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| 95% dip 0.5 periods, 30%
dip 25 periods,95% interruptions 250 periods
****OTHERS| MTBF| 1380.2K hrs min. Telcordia TR/SR-332
(Bellcore) ; 191.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 21810561.5mm (LWH)
PACKING| 1.39Kg;8pcs/12.1Kg/1.58CUFT
****NOTE**|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com )※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Function Manual
Pav: Average output power (W)
Py : Peak output power (W)
Pas : Non-peak output power (W)
Patea : Rated output power (W)
t : Peak power width(sec)
T: Period(sec)
For example (24V model) :
Remote Sense
The remote sensing compensates voltage drop on the load wiring upto 0.5V.
DC-OK Signal
DC-OK signal isa TTL level signal. High when PSU turns on.
Between DC-OK(pin1) and GND(pin2) | Output Status |
---|---|
3.3 ~ 5.6V | ON |
0 ~ 1V | OFF |
Mechanical Specification
AC Input Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1 | AC/L |
2 | AC/N |
3 | FG |
DC Output Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1~2 | -V |
3~4 | +V |
Connector Pin No. Assignment(CN100) : HRS DF 11-4DP-2DS or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | DC-OK | HRS DF11-4DSor equivalent | HRS DF11-**SCor equivalent |
2 | GND | ||
3 | +S | ||
4 | -S |