CHARACTERISTICS

Electrical Characteristics

  • External power supply with 220/18VAC transformer
  • Fuse protection 2A

Electronic Characteristics

  • Photocell to detect label presence
  • Tachometer to control the label length
  • Display with 2 lines of 16 characters

Electrical Characteristics

  • Personalization of company name
  • Photocell function control
  • Programmable quantity of labels to detach from 0 to 999
  • Continual display of the detached label quantity
  • Continual display of the number of detached label series
  • Programmable length of the detached part of the label
  • Three different feed types
  • An acoustic alarm sounds when the number of label series reaches the programmed quantity
  • Programmable series from 2 to 3 labels of different lengths

Mechanical Characteristics

  • Maximum dimensions DN01 and DN02: W=330mm (12.99”); H=240mm (9.45”); D=410mm (16.14”) DP02: W=320mm (12.60”); H=210mm (8.26”); D=260mm (10.24”) DP03: W=240mm; H=210mm (8.26”); D=260mm (10.24”)
  • Speed 120 rpm
  • Roll diameter up to 300mm (11.81”) (DN01 – DN02) or 200mm (7.87”) (DP02 – DP03)
  • Core holder from 30mm (1.18”)
  • Label width up to 70mm (2.75”) (DP03), 150mm (5.90”) (DN01 – DP02), or 210mm (8.26”) (DN02)
  • Table to write on the label if required before removal
  • Mechanical regulation of the clutch

PROGRAMMING

Exiting Menu

IMPORTANT
To exit at any moment from the programming mode and implement an alarm reset, push this button.
When first switched on the panel will display the following: ****

Enable First Menu
Push this button to enter into the program mode and the panel will indicate that you wish to detach one series label at a time.DPR DN01 DN02 DP03 DP02
Label Dispenser - Figure

Push this button again if you don’t want to select the series type and set the detached label length.
By successively pushing these buttons you can change the series from 1 to 3 labels. Even if they are of different sizes but are part of a single series the panel will display it:DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure23

Having established the type of series to use, when pushing these buttons for each type of label, it is possible to modify the length of the label section that needs to be detached for every single label. The panel will then display the following three types of messages.DPR DN01 DN02 DP03 DP02 Label
Dispenser - Figure24

Enable Second Menu
By successfully pushing these buttons you can choose three different feed types.

DPR DN01 DN02 DP03 DP02 Label Dispenser - Figure3

> Temporized feed
This option allows the user to define the detach delay time from 1 to 60 seconds between labels.
To run this option please follow the next operation.DPR DN01 DN02 DP03 DP02
Label Dispenser - Figure4

By successively pushing this button you enter the setting seconds menu.DPR
DN01 DN02 DP03 DP02 Label Dispenser - Figure5

By successfully pushing these buttons you can select the detach delay time from 1 to 60 seconds between labels.
Example: In this case, you can detach a label every 15 seconds.DPR DN01 DN02
DP03 DP02 Label Dispenser - Figure6

Automatic feed
This function dispenses the labels automatically.
> Manual feed
This function dispenses the label only if you push the ESC button or the pedal (optional accessory).

DPR DN01 DN02 DP03 DP02 Label Dispenser - Figure7

IMPORTANT
In both cases, the dispenser will be stopped if the counter function is active and you reach the set number of labels.
Enable Third Menu
By successfully pushing this button you can select the counter function that presets the number of labels to detach. The panel will then display the following two types of messages.

Push this button to choose between having the counter function on or off.
When selecting “ACTIVE COUNTER YES” you can define the number of labels to detach and the panel will display the sequential counter with the option to select from 1 to 9999 labels or a series of labels to detach.

DPR DN01 DN02 DP03 DP02 Label Dispenser - Figure8

By pushing these buttons you can select the 4 digits of the counter one at a time.
Once selected, the digit to be modified can be changed between a value from 0 to 9.
IMPORTANT
To ensure that the detached labels correspond to the number selected under the active counter menu YOU MUST push this button for a few seconds to reset the counter. ****

IMPORTANT
With the manual function, Automatic feed ON, the counter reset will display “0001” because the first label available for detachment will be displayed.DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure10

NOTE:
During operation, once the last label that was programmed detaches the dispenser will stop and emit an acoustic warning signal. To turn off the alarm and reset the counter push this button.
When selecting “ACTIVE COUNTER NO” the counter is disabled and the labels can be detached with undefined quantities.DPR DN01 DN02 DP03 DP02 Label
Dispenser - Figure11

Enable Fourth Menu
By successfully pushing this button you can enable the function that allows the customers’ name to appear on the display.DPR DN01 DN02 DP03 DP02 Label
Dispenser - Figure12

By pushing these buttons you can select the 16 digits of the counter one after another in order to insert the required text.
Having selected the digit to program with these buttons, you can change the value with letters, numbers, and symbols.
By successfully pushing this button you enable the control of the sensor functions for label presence. All of the digits will be on, as shown below with the functioning sensors, not in use.DPR DN01 DN02 DP03 DP02 Label
Dispenser - Figure13

By covering the sensor next to the panel with a finger, the digits turn off. As shown in the following demonstrates the use of the sensors by the label.DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure14

MOTOR MANUAL ADVANCE
Press this key for manual advance of the motor.
COUNTER ZERO SETTING
Press this key for 4 seconds to reset the counter to 0. When reset the dispenser will emit a sound.
ROLL LOAD ON THE DISPENSER
Load the roll of labels on the hub. Tighten the roll by attaching the plate. The tighter the plate the more tension is applied to the roll.
Note: If during standard operation more than one label is detached pls increase the pressure on the plate springs.DPR DN01 DN02 DP03 DP02 Label
Dispenser - Figure15

Follow the loading procedure as seen below:
Open the drag roller and pass the backing through the rollers.DPR DN01 DN02
DP03 DP02 Label Dispenser - Figure16

Block the backing with the fork on the recovery roller. Close the drag roller.DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure17

Push the displayed button to roll up the backing on the recovery roll.DPR
DN01 DN02 DP03 DP02 Label Dispenser - Figure18

SENSOR CALIBRATION

IMPORTANT
**** The device is calibrated in our lab, please do the following operations only if necessary.
Without any label between the sensors, the digits on the display must be black.DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure19

Put a label away from the plate 20mm, the digits on the display should be white; if not pls unscrew sensor 2 and move it up or down to obtain this condition then tighten the screws.DPR DN01 DN02 DP03 DP02 Label Dispenser -
Figure20

SMART SOLUTIONS FOR THE LABELING INDUSTRY

Label rewinder

DPR DN01 DN02 DP03 DP02 Label Dispenser -Figure – FOR MORE INFO CONTACT YOUR RESELLER –

Documents / Resources

| DPR DN01, DN02, DP03, DP02 Label Dispenser [pdf] User Manual
DN01, DN02, DP03, DP02, Label Dispenser, Dispenser
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals