CHARACTERISTICS
Electrical Characteristics
- External power supply with 220/18VAC transformer
- Fuse protection 2A
Electronic Characteristics
- Photocell to detect label presence
- Tachometer to control the label length
- Display with 2 lines of 16 characters
Electrical Characteristics
- Personalization of company name
- Photocell function control
- Programmable quantity of labels to detach from 0 to 999
- Continual display of the detached label quantity
- Continual display of the number of detached label series
- Programmable length of the detached part of the label
- Three different feed types
- An acoustic alarm sounds when the number of label series reaches the programmed quantity
- Programmable series from 2 to 3 labels of different lengths
Mechanical Characteristics
- Maximum dimensions DN01 and DN02: W=330mm (12.99”); H=240mm (9.45”); D=410mm (16.14”) DP02: W=320mm (12.60”); H=210mm (8.26”); D=260mm (10.24”) DP03: W=240mm; H=210mm (8.26”); D=260mm (10.24”)
- Speed 120 rpm
- Roll diameter up to 300mm (11.81”) (DN01 – DN02) or 200mm (7.87”) (DP02 – DP03)
- Core holder from 30mm (1.18”)
- Label width up to 70mm (2.75”) (DP03), 150mm (5.90”) (DN01 – DP02), or 210mm (8.26”) (DN02)
- Table to write on the label if required before removal
- Mechanical regulation of the clutch
PROGRAMMING
Exiting Menu
IMPORTANT
To exit at any moment from the programming mode and implement an alarm reset,
push this button.
When first switched on the panel will display the following: ****
Enable First Menu
Push this button to enter into the program mode and the panel will indicate
that you wish to detach one series label at a time.
Push this button again if you don’t want to select the series type and set the
detached label length.
By successively pushing these buttons you can change the series from 1 to 3
labels. Even if they are of different sizes but are part of a single series
the panel will display it:
Having established the type of series to use, when pushing these buttons for each type of label, it is possible to modify the length of the label section that needs to be detached for every single label. The panel will then display the following three types of messages.
Enable Second Menu
By successfully pushing these buttons you can choose three different feed
types.
> Temporized feed
This option allows the user to define the detach delay time from 1 to 60
seconds between labels.
To run this option please follow the next operation.
By successively pushing this button you enter the setting seconds menu.
By successfully pushing these buttons you can select the detach delay time
from 1 to 60 seconds between labels.
Example: In this case, you can detach a label every 15 seconds.
Automatic feed
This function dispenses the labels automatically.
> Manual feed
This function dispenses the label only if you push the ESC button or the pedal
(optional accessory).
IMPORTANT
In both cases, the dispenser will be stopped if the counter function is active
and you reach the set number of labels.
Enable Third Menu
By successfully pushing this button you can select the counter function that
presets the number of labels to detach. The panel will then display the
following two types of messages.
Push this button to choose between having the counter function on or off.
When selecting “ACTIVE COUNTER YES” you can define the number of labels to
detach and the panel will display the sequential counter with the option to
select from 1 to 9999 labels or a series of labels to detach.
By pushing these buttons you can select the 4 digits of the counter one at a
time.
Once selected, the digit to be modified can be changed between a value from 0
to 9.
IMPORTANT
To ensure that the detached labels correspond to the number selected under the
active counter menu YOU MUST push this button for a few seconds to reset the
counter. ****
IMPORTANT
With the manual function, Automatic feed ON, the counter reset will display
“0001” because the first label available for detachment will be
displayed.
NOTE:
During operation, once the last label that was programmed detaches the
dispenser will stop and emit an acoustic warning signal. To turn off the alarm
and reset the counter push this button.
When selecting “ACTIVE COUNTER NO” the counter is disabled and the labels
can be detached with undefined quantities.
Enable Fourth Menu
By successfully pushing this button you can enable the function that allows
the customers’ name to appear on the display.
By pushing these buttons you can select the 16 digits of the counter one after
another in order to insert the required text.
Having selected the digit to program with these buttons, you can change the
value with letters, numbers, and symbols.
By successfully pushing this button you enable the control of the sensor
functions for label presence. All of the digits will be on, as shown below
with the functioning sensors, not in use.
By covering the sensor next to the panel with a finger, the digits turn off. As shown in the following demonstrates the use of the sensors by the label.
MOTOR MANUAL ADVANCE
Press this key for manual advance of the motor.
COUNTER ZERO SETTING
Press this key for 4 seconds to reset the counter to 0. When reset the
dispenser will emit a sound.
ROLL LOAD ON THE DISPENSER
Load the roll of labels on the hub. Tighten the roll by attaching the plate.
The tighter the plate the more tension is applied to the roll.
Note: If during standard operation more than one label is detached pls
increase the pressure on the plate springs.
Follow the loading procedure as seen below:
Open the drag roller and pass the backing through the rollers.
Block the backing with the fork on the recovery roller. Close the drag roller.
Push the displayed button to roll up the backing on the recovery roll.
SENSOR CALIBRATION
IMPORTANT
**** The device is calibrated in our lab, please do the following
operations only if necessary.
Without any label between the sensors, the digits on the display must be
black.
Put a label away from the plate 20mm, the digits on the display should be white; if not pls unscrew sensor 2 and move it up or down to obtain this condition then tighten the screws.