SAFETY
READ AND SAVE THESE INSTRUCTIONS
IMPROPER HANDLING CAN CAUSE SERIOUS DAMAGE TO PEOPLE AND TO THE APPLIANCE. IN
CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND
ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH
VERSION SHALL PREVAIL.
WARNING:
- DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent.
- DO NOT cover the air intake and exhaust when in use.
- This appliance is not intended for use by children. Children should be supervised and should not play on or around the appliance.
- DO NOT place objects on or sit on the unit.
- Always turn off and unplug the unit when cleaning or servicing.
- If service is needed contact an authorized service agent.
- Unplug the unit when stored or not in use.
- DO NOT run the power cord under carpeting and rugs.
- Use caution to prevent tripping on cord.
- DO NOT use in areas where gasoline, paint or other flammable goods are stored.
- Basic safety precautions should always be followed when using electrical appliances.
- This household appliance has been manufactured for use in domestic environments and should not be used for other purposes.
- Only use the installation kit provided to install this unit. DO NOT attempt to extend the exhaust hose or install this unit using other methods other than that provided in this manual. Improper installation could void any existing warranties. Contact Customer Support for assistance if required.
- DO NOT use an extension cord with this unit.
THANK YOU
Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner.
USER TIPS
Honeywell Portable Air Conditioners are ideal for spot cooling. The
compressor, condenser and evaporator are housed in a compact unit. The air is
filtered, dehumidified and cooled while a flexible air outlet hose sends heat
outside. The air conditioner includes a window venting kit.
No permanent installation is needed. The unit is easy to move from room to
room and offers a truly flexible air conditioning solution.
Auto Evaporation System – The unit automatically evaporates the condensate
through the air outlet hose. There is no need to empty the drainage tank
except in very humid conditions.
Read and follow the instructions carefully.
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize.
Air outlet automatically opens when the unit is turned on, and automatically closes when the unit is turned off. Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
- Follow installation instructions to set up the unit.
- Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
PARTS DESCRIPTION
-
Control Panel
-
Air Outlet
-
Handle
-
Casters
-
Remote Control
-
Exhaust Hose Connector
-
Cord Winder
-
Upper Grill
-
Upper Air Filter
-
Upper Rubber Drain Plug
(Dehumidifying Mode) -
Lower Air Filter
-
Lower Grill
-
Drain Tube
(For Continuous Drain) -
Lower Rubber Drain Plug
(Air Conditioning Mode) -
Power Supply Cord
INSTALLATION
IMPORTANT:
- Do not replace or lengthen the exhaust hose as this could cause the unit to malfunction.
WARNING : Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer’s instructions, without proper consultation. Please contact Customer Support for help with installation procedures if needed.
- The supplied exhaust hose has a diameter of 5 inches (12.7cm) and can be extended from 12 inches to 47 inches (30cm to 120cm).
- Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off.
- Make sure the back of the unit is at least 50 cm / 20 inches away from the wall. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.
USE & OPERATION
CONTROL PANEL
POWER CONTROL
The Power Control ****turns the unit on and off. When the unit is plugged into an appropriate electrical outlet, the POWER indicator light will illuminate red indicating the unit is in a Standby Mode, ready to be switched on at anytime. The air vent will automatically open when the unit is turned ON and automatically close when unit is turned OFF.
FUNCTION BUTTONS (CONTINUED)
MODE CONTROL
Setting COOL,DRY,FAN and HEAT*
The corresponding indicator light will illuminate to indicate the current mode
setting.
-
Air Conditioning Mode (COOL)
Adjust fan speed and air temperature to suit your desired comfort level.
Temperature setting range is 16°C- 32°C (61°F- 89°F). -
Dehumidifying Mode (DRY)
Fan speed is preset to LOW.
Note : If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose. Continuous drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode). -
Fan Mode (FAN)
For air circulation without air conditioner cooling. -
Heating Mode* (HEAT)
In this mode, the desired temperature can be set between 16°C- 32°C (61°F- 89°F) When in heating mode condensation must be drained from the lower drain plug.
Note : The air exchange hoses must vent outside the room when using heating mode. -
Sleep Mode (SLEEP)
When the Sleep Mode is activated in Air Conditioning mode, the set temperature will increase by 1°F or 1°C after the first hour of cooling and will increase a further 1°F or 1°C after the second hour of cooling. The unit will maintain this temperature for 5 hours. The set temperature will then reduce by 1°F or 1°C on the seventh hour and reduce a further 1°F or 1°C on the tenth hour. Sleep mode will then deactivate automatically.
IN Heating Mode, the set temperature will reduce by 2°F or 2°C after the
first hour of heating and will educe a further 2°F or 2°C after the second
hour of heating. The unit maintains heating at this emperature for 5 hours.
Then, the set temperature will increase 2°F or 2°C at the seventh hour and
will increase a further 2°F or 2°C on the tenth hour. Sleep mode will then
deactivate automatically.
Note : The Sleep Mode can be deactivated during cooling or heating mode
by pressing any button at any time.
FAN SPEED CONTROL
3 settings: High, Medium and Low.
TIMER CONTROL
The Timer is adjustable between 1-24 hours.
AUTO TURN OFF:
While unit is running, press the TIMER button and the display will flash.
While the display is flashing, press the or-button to select the number of
hours you want the unit to turn OFF automatically.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), press the
TIMER button and the display will flash. While the display is flashing, press
the + or button to select the number of hours until you want the unit to turn
ON automatically.
TEMPERATURE CONTROL
- Used for adjusting the timer and thermostat.
- The default display is room temperature.
- In cooling mode, when + or-button is pressed, the set temperature is displayed and may be adjusted. After 5 seconds the display will revert back to room temperature.
Note : By pressing both +/-buttons at the same time, the display will toggle between Celsius and Fahrenheit.
WATER FULL LIGHT
Condensation may accumulate in the unit. If the bottom internal tank is
full, the WATER FULL light will illuminate and an alarm will beep for 30
seconds. The unit will not operate until the water has been drained from the
bottom drain plug (refer to Water Condensation Drainage).
After switching the air conditioner off, the compressor will not start immediately. You must wait about 4 minutes before it switches back on again.
REMOTE CONTROL
The functions work the same as the portable air conditioner’s Touch Screen
Control Panel.
All key functions can be accessed from the remote control.
*Applicable for models with Heating feature only.
Note:
- Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and – pointing in the proper direction according to the polarity markings.
Caution:
- Use only two AAA or IEC R03 1.5V batteries.
- Remove the batteries if the remote control is not in use for a month or longer.
- All batteries should be replaced at the same time, do not mix with old batteries.
- Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
- Properly dispose of used batteries.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment info an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
CLEANING & MAINTENANCE
Appliance Maintenance:
- Turn off the appliance before disconnecting the power supply.
- Only clean the appliance with a soft dry cloth.
Air Filter Maintenance:
The air filter is to be cleaned every two weeks to maintain a cleaner
environment and air cooling efficiency. Please follow the below instructions
for cleaning the air filters:
-
Switch off and unplug the air conditioner from the electrical outlet.
-
Remove the Upper Filter/Grill and unscrew the Lower Filter/Grill and carefully remove.
-
Gently wash using water and/or diluted liquid dishwashing detergent. Rinse thoroughly and gently shake excess water from the filters.
Make sure the filters are dry before reinstalling.
Note : You may use a vacuum cleaner to remove dust. -
Replace the Upper Grill onto the unit, and reinstall the Lower Grill with the screws.
WARNING : DO NOT power or operate the Air Conditioner when cleaning or when any or both of the Rear Grills are removed from the unit, or if there is a loose-fitting Rear Grill(s). DO NOT attempt to handle or touch any of the parts or wiring inside the air conditioner after the Rear Grill(s) are removed from the unit. Doing so can cause serious injury or electrical shock.
End of Season Storage & Maintenance:
If the appliance will not be used for a long time:
-
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a shallow pan to collect the water (make sure to replace the drain plug when finished).
-
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
-
Turn off and unplug the air conditioner from the power supply.
-
Remove the air filter and clean with water. Dry the air filter and then reinstall.
-
Disconnecting the Window Installation Kit:
Remove the Plastic Hose from the unit.
Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit.
If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage. -
Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit.
-
It is recommended to coil the power cord before storing to ensure the cord is protected from bents and creases.
-
Store the air conditioner in a cool, dry place, away from direct sunlight.
WATER CONDENSATION DRAINAGE
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the Power Control button flashes with a red light). This warning light indicates that the water condensation needs to be drained using the following procedures.
Manual Draining for Cooling, Heating & Dehumidifier Mode
Water may need to be drained in high humidity areas.
- Unplug the unit from power source.
- Place a shallow pan under the lower rubber drain plug. See diagram.
- Remove the rubber drain plug.
- Water will drain out and collect in the shallow pan.
- After the water is drained, replace the rubber drain plug.
- You can now turn on the unit.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is
recommended.
- Unplug the unit from the power source.
- Remove the upper/lower rubber drain plug. Some residual water may spill so please have a pan to collect the water.
- Connect the drain tube (included) to the upper or lower drain (whichever is more convenient for your space). See diagram.
- The water can be continuously drained through the drain tube into a floor drain or bucket.
- Replace the drain plug.
- You can now turn on the unit.
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.
Made in China
© 2016 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license from Honeywell International
Inc.
Honeywell International Inc. makes no representations or warranties with
respect to this product.
This product is manufactured by Airtek Int’l Corp. Ltd.
(subsidiary of JMATEK Ltd.).
JMATEK North America LLC
Mahwah, New Jersey 07495 USA
Email: usinfo@jmatek.com
Web: www.jmatek.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>