VIMAR 30403.G LINEA Smart Switch Instruction Manual

June 13, 2024
VIMAR

LINEA
30403.x

CONNECTIONS

INSTALLATION

VIMAR 30403 G LINEA Smart Switch - INSTALLATION 1

REGULATING THE TRIMMER

VIMAR 30403 G LINEA Smart Switch - REGULATING THE
TRIMMER

COVER REMOVAL

FEATURES

Power supply 120-240 V~ ± 10% 50/60 Hz
Output relay with clean change-over contact 4 A 250 V~ cos φ 1 N.O. (NO SELV)
Typical absorption 25 mA – 120 V~

40 mA – 240 V~
Operating temperature| -5 °C – +35 °C
indoor use

CONTROLLABLE LOADS AT 120-240 V~

Cycles

| Resistive loads| 4 A
---|---|---
| Motors cos φ 0.6| 2 A

INSTALLATION RULES

The relay output power supply circuit must be protected against overcurrent’s by installing a device, a fuse with a rated breaking capacity of 1500 A or a type-C circuit breaker, with rated current not exceeding 10 A.

REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead

DEVICE DETAILS, CONFIGURATION AND WEEE INFORMATION CAN BE DOWNLOADED IN PDF FORMAT FROM THE PRODUCT DATA SHEET ON www.vimar.com (the QR code opens the data sheet of art. 30403.B, which shares the same instructions sheet as art. 30403.x).

VIMAR 30403 G LINEA Smart Switch - QR Code 1https://www.vimar.com/en/int/catalog/product/index/code/30403.B

49401724A0 03 2303

Viale Vicenza, 14
36063 Marostica VI – Italy
www.vimar.com