Specifications
- Model: LINE 30292.ACx
- Input Voltage: 120-240V~ 50/60Hz
- Output: 5.0V 2.4A 12.0W
- Plug Diameter: 6mm
- Current: 230mA
- Frequency: 50/60Hz
- Efficiency: 82.5%
- Protection Rating: IP20
Power Supply Connection
Ensure the input voltage is within the range of 120-240V~ 50/60Hz. Connect the device to a compatible power outlet.
Output Connection
Use the provided 6mm plug to connect your device to the output port of the LINEA 30292.ACx.
Power Consumption
The device has an output of 5.0V, 2.4A, and consumes 12.0W of power during operation.
Safety Information
Ensure the device is used in a dry indoor environment as it has an IP20
protection rating. Read the instructions before installation and/or use.
FRONT AND REAR VIEW
- Type A USB port
- Type C USB port
N.B. Graphic representation of the Linea series. The position of terminals, wiring and functions is also identical for Eikon, Arké, Idea and Plana.
FEATURES
- Power supply 120-240 V~ 50/60 Hz
- Power consumption 230 mA – 120 V~145 mA – 240 V
- Output voltage 5.0 V d.c. (± 5%) ES1 e/o
- Max output load 2.4 A
- Output power 12.0 W
- Average efficiency in active mode 82.5%
- Efficiency with low load (10%) 80%
- Power with no load 0.06 W
- Protection degree IP20
- Operating temperature 0 °C – +35 °C indoor use
- Device in class II
Installation for CAT III overvoltage category.
INSTALLATION RULES
Installation must be carried out by qualified persons in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed. The device can be installed in a flush mounting box or surface mounting box and completed with Linea, Eikon, Arké or Plana cover plates in dust-free places, protected from accidental impacts and away from heat sources.
IMPORTANT
- An easily accessible omnipolar disconnection switch with a contact gap of at least 3 mm must be installed upstream from the power supply.
- Install the device at a height of no more than 2 m.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead. DEVICE DETAILS AND WEEE INFORMATION CAN BE DOWNLOADED IN PDF FORMAT
FROM THE PRODUCT DATA SHEET ON www.vimar.com (the QR
code opens the data sheet of art. 30292.ACB, which shares the same
instructions sheet as art. 30292.
ACx-20292.AC-19292.AC-14292.AC).
Viale Vicenza, 14
36063 Marostica VI – Italy
49401687A0 02 2401 www.vimar.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>