VIMAR 692U Two Wire Unit for BW AV Panel Instruction Manual

June 1, 2024
VIMAR

VIMAR 692U Two Wire Unit for BW AV Panel Installer manual
692U – 692U/C
B/w a/v entrance panel Due Fili unit
– Colour a/v ent. panel Due Fili unit

The instruction manual is downloadable from the site www.vimar.com
These types of camera and can be mounted only on entrance panels series 8100.

Technical features of cameras

– ¼’’ CCD sensor
– 3 mm lens with fixed focus
– Automatic lighting control.
– Video signal: Standard CCIR 625 lines, 50 images for B/N and PAL for colour
– Operating temperature -5° to +50°C
– Infrared subject lighting for B/W camera and white for colour camera.
– Name-tag holder lit by LEDs
– Built-in speech unit
– Removable terminal block for connection.
– Local door lock release with the same timing as the door lock release from the video interphone, which can be adjusted between 1 and 30 seconds by means of a trimmer.
– Supply voltage provided by bus.
– Maximum overall dimensions 80x120x25 mm.
– “Engaged Please Wait” message

Camera adjustments

The following adjustments are available on the back of the camera:

| External volume
---|---
| Camera activation time (call conversation self-start)
| Lock activation time

INSTALLATION

Assembly and installation of Type 692U or 692U/C involves the following phases:
– Installation of entrance panel
– Routing of cables
– Connection of speech unit to system
– Programming of speech unit
N.B. Do not connect the terminal block of the speech unit to the system until the wires (green, black and white) have been connected to the entrance panel.
Camera terminals

S: Lock (open collector)
TEL: Not used
B1: 2-wire bus
B2: 2-wire bus
M: Ground / Video ground
PA Input for the open door (connect to M).
CA: Door lock release (connect to M)
M: Ground
12V: Output +12V max 100mA.

OPERATING TIMES
On Type 692U, 692U/C the times are adjusted by means of trimmers located in the middle at the top:
LOCK ACTIVATION TIME:
Adjusts lock activation time from a minimum of 1 to a maximum of 30 seconds.
CAMERA TIME:
Adjusts the activation time of the camera for the 3 modes in which it can operate:

MODE MINIMUM MAXIMUM
CALL 7.5 30
CONVERSATION 30 120
SELF-START 5 20

The ratio between these two times is always constant:
Self-Start = 1/6 conversation
Call = 1/4 conversation

EXTERNAL VOLUME

The external volume is adjusted with the external volume trimmer located behind the camera

ASSIGNING THE CALL PUSH-BUTTON

Press the reset push-button on the speech unit, hold the call push-button down and release the reset push-button. After two seconds, the unit’s loudspeaker emits a high-pitched tone. The call push-button must be released within two seconds. From the rest state, when the handset is lifted, all the devices (interphones/video interphones) react by emitting a three-tone ascending scale through the loudspeaker.
As of this moment, you have 25 seconds to press any push-button on the interphones/video interphones controlling an actuator (usually the stairlight control), F1 or F2 function, or in the last instance the door lock release push-button on the device you intend to
assign to the call push-button of the speech unit. When this is done, a low- pitched tone is emitted by the loudspeaker. The same sound is emitted when the timeout elapses.
IMPORTANT: IF YOU USE THE DOOR LOCK RELEASE PUSH-BUTTON, THE LOCK CONNECTED TO AN ENTRANCE PANEL MAY BE OPENED.

CALL
The call ringtone generated by an entrance panel does not follow the rhythm of the pressed push-button, but is electronically regenerated. The number of cycles is programmed in each entrance panel and has a default setting of 2. The ringtone follows the  sequenceof 1 second of sound followed by a 2 second pause. This applies to the ringtone on monitors/ interphones as well as any call control on the entrance panel.
The monitor switches on immediately and an answer can be given at any moment within the time set on the entrance panel, the timing of which starts from the end of the last ringtone cycle.
To answer, simply lift the handset. If the handset is already lifted when the call is received, press and release the ‘hook’ to enable conversation. The duration of conversation is set on each entrance panel.
After this conversation time dwell, if a new call is effected from the panel within 10 seconds, it is possible to answer directly without hooking the handset.

RINGTONE MUTING

If a call is made to an interphone or monitor with the ringtone mute enabled, the panel indicates that the call cannot be sent, with the emission of a dissuasion tone for a few seconds, of very short repeated “Beeps.

ENGAGED

If a call is in progress on the same section of the bus in which the entrance panel is inserted, the ENGAGED-PLEASE WAIT message lights up until the line is free. Separator Type 692S prevents an engaged cable riser from blocking any other riser, thus allowing simultaneous communications.
The advanced configurations can be set by means of programming module Type 950C connected to CN7 inside camera Type 692U, or with the PC Software SaveProg Type 69CD, in this case it is necessary to have the interfaces Type 692I or Type 692I/U.

Entrance panel dimensions

VIMAR 692U Two Wire Unit for BW AV Panel - panel
dimensions

Opening the entrance panel

VIMAR 692U Two Wire Unit for BW AV Panel - panel dimensions
1VIMAR 692U Two Wire Unit for BW AV
Panel - panel dimensions 2

PANEL INSTALLATION

To separate the base of the entrance panel from the plate:
With a screwdriver, press the left-hand side of the sliding door marked with the ELVOX logo. Slide the door to the left and use the wrench supplied for opening and closing the entrance panel (Fig. 1).
Before installing equipment, choose location for camera entrance panel: the camera should be protected from direct light (sun, car headlights, etc.) as this may affect the quality of the picture, and may damage the camera.
Type 692U is a B/W camera with speech unit, while type 692U/C is a colour camera with speech unit.
Mount the entrance panels with the screws and expansion plugs supplied, or on a 3-module vertical box. Entrance panels with cameras should be installed at the height of 1,65 m. measured from the top edge of the entrance panel to the ground. Fit camera in its seat in the entrance panel (as shown in Fig. 2-3), and position the entrance panel microphone as shown in Fig. 4.
Fig. 2 shows the set of entrance panel components:
A – Front plate
B – Base of plate
C – Camera
Connect the black/red wire to the ENGAGED-PLEASE WAIT connector  onthe back of he front plate of the entrance panel A (Fig. 2).
Connect the green wires to the entrance panel push-button, and the black and white wires to the entrance panel LED (Fig. 2 and Fig. 4).
N.B. Do not connect the terminal block of the camera to the system until the wires (green, black and white) have been connected to the entrance panel.
Lastly connect camera to the system with the terminal block.

BUS TERMINATION
In the bottom left-hand corner of the camera is a connector with 4 positions (Fig. 5).
A jumper in one of the three possible positions (A-B, B-C, C-D), terminates the bus correctly for the video signal. Experiment to determine the optimum compromise to provide best overall vision from all the entrance panels in the system.

ASSIGNING IDENTIFICATION

The ID (entrance panel identification code) is assigned by means of 4 DIP- switches in the bottom left-hand corner of the camera (see Fig. 6). Each entrance panel in the same system must have a different identification code. The correlation between the position
of the DIP-switches and the identifier is shown in table 1.VIMAR 692U Two
Wire Unit for BW AV Panel - panel dimensions 3 Table 1

VIMAR 692U Two Wire Unit for BW AV Panel - DIP SWITCH ENTRANCE PANEL ID

NOT ASSIGNE= TEST/ID DANS EEPROM
As you can see, Type 692U can never be programmed as MASTER entrance panel. Position 1 is used for factory testing.
Legenda for wiring diagram Min
Mimum conductor section

Terminals Ø up to 10m
Electric lock 1,5 mm2
Others – , +U, +I, -L (#) 1 mm 2

Additional power supply units (type 6923, 6582, 6982) must be installed as near as possible to the device to which they are connected.

C1 – OUTDOOR AUDIO ENTRANCE PANEL, TYPE 8100 Art. 81B1, WITH SPEECH UNIT 69AU
D – VIDÉO ENTRANCE PANEL SERIES89F5/C.., 89F7/C
D1- OUTDOOR VIDÉO ENTRANCE PANEL SERIES 8100 Art. 81V1 WITH CAMERA TYPE 692U

OR 692U/C
c4- d4 –| “ENGAGED – PLEASE WAIT” SIGN
c2-d2 –| CALL PUSH-BUTTON
c3-d3 –| LED FOR NAME-TAG LIGHTING
F –| POWER SUPPLY Type 6922
I –| SEPARATOR Type 692S
K –| PUSH-BUTTON FOR OUTDOOR CALL
L –| 12V DC ELECTRIC LOCK
P –| LOCK RELEASE CONTROL
R –| TRANSFORMER ART.832/030

Video door entry system in building complex with one main video entrance panel and two outdoor entrance panels, of which one video with camera Art. 692U and one with speech unit Art. 69au (Ref. SC5436).VIMAR 692U Two Wire Unit for BW
AV Panel - Video door entry system

* BUS TERMINATION

This note applies to all devices with Due Fili Plus technology equipped with “BUS termination connector or dipswitch”, which is identified by the screen- printed letters
“ABC” and marked on the wiring diagrams with.
For correct adaptation of the line, make the setting according to the following rule:
Maintain position “A” if the BUS enters and exits from the device;  Move to position “B” (if Elvox cable) or to position “C” (if CAT5 twisted pair cable) if the BUS line terminates in the device itself.
“A” = NO TERMINATION
“B” = TERMINATION 100 ohm
“C” = TERMINATION 50 ohm
INSTALLATIONS WITH PASSIVE DISTRIBUTOR 692D (DIN rail version)
ALWAYS use output 1 on distributor type 692D (the only one that has no termination jumper).
For termination of type 692D: If outputs “OUT”, “2”, “3” or “4” are not used, KEEP the jumper on the “TOUT”, “T2”, “T3” or “T4” connector. The default “TOUT” connector is in the “100” position (Elvox cable), position it to “50” only if using a CAT5 twisted pair cable.
INSTALLATIONS WITH ACTIVE DISTRIBUTOR 692D/2.
The termination jumper must be positioned on “B” (for Elvox cable) or on “C” (for CAT5 twisted pair cable) IF AND ONLY IF the BUS terminates at the device itself. It must be left on “A” if effecting entry-exit using terminals 1-2 on 692D/2
.

The instruction manual is downloadable from the site www.vimar.com
Installation rules
Installation should be carried out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
Conformity
EMC directive
Standards EN 61000-6-1 and EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE – Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least 400m , if they measure less than 25cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health, and encourages the re-use and/or recycling of the construction materials.

Viale Vicenza, 14
36063 Marostica VI – Italy
www.vimar.com
S6I.692.U00 09 2309

Documents / Resources

| VIMAR 692U Two Wire Unit for BW AV Panel [pdf] Instruction Manual
692U Two Wire Unit for BW AV Panel, 692U, Two Wire Unit for BW AV Panel, Wire Unit for BW AV Panel, Unit for BW AV Panel, BW AV Panel, AV Panel
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals