BEA 10ECA EAGLE Ceiling Adapter Instruction Manual
- June 13, 2024
- BEA
Table of Contents
BEA 10ECA EAGLE Ceiling Adapter
Product Information
The product is a part of the EAGLE Family Accessories and includes the following items:
- RAIN COVER 10ERC
- RAIN ACCESSORY 10ERA
- MOUNTING BRACKET 10EMB
- CEILING ACCESSORY 10ECA
- SPACER 10EAGLESPACER
- EAGLE SPACER V 10EAGLESPACERV
The product is manufactured by BEA, Inc. and is intended for installation and setup in pedestrian doors or gates.
It is important to note the following precautions:
- Maintain a clean and safe environment when working in public areas.
- Be aware of pedestrian traffic around the door area.
- Stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
- Ensure compliance with all applicable safety standards upon completion of installation.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring compliance with local, national, and international regulations, codes, and standards.
The product installation and service technicians are recommended to be AAADM-
certified for pedestrian doors, IDA-certified for doors/gates, and factory-
trained for the type of door/gate system.
All appropriate industry signage, warning labels, and placards should be in
place.
Product Usage Instructions
RAIN COVER 10ERC
To install the RAIN COVER 10ERC:
- Align the RAIN COVER with the EAGLE and wall mounting holes.
- Route the EAGLE Harness through the wall/header and then through the designated pass-thru on the spacer.
- Mount the spacer to the wall/header using self-drilling screws.
- Route the EAGLE Harness through the pass-thru on the sensor.
- Mount the sensor to the accessory.
- Wire the EAGLE Harness to the sensor.
CEILING ACCESSORY 10ECA
To install the CEILING ACCESSORY 10ECA:
- Align the CEILING ACCESSORY with the EAGLE and wall mounting holes.
- Mount the spacer to the wall/header using self-drilling screws.
- Route the EAGLE Harness through the pass-thru on the sensor.
- Mount the sensor to the accessory.
- Wire the EAGLE Harness to the sensor.
More Information
PRECAUTIONS
- Maintain a clean and safe environment when working in public areas.
- Constantly be aware of pedestrian traffic around the door area.
- Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
- Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
Reference EAGLE FAMILY User’s Guide (75.5957) for full EAGLE installation and setup.
INSTALLATION
SPACER / SPACER V 10EAGLESPACER / 10EAGLESPACERV
- Pre-drill the EAGLE Harness passage hole (1⁄4” for SPACER, 1⁄2” for SPACER V).
- Route the EAGLE Harness through the wall/header and then through the designated pass-thru on the spacer.
- Route the EAGLE SPACER V camera harness through the wall/header and then plug into SPACER V connector.
- Mount the spacer to wall/header using self-drilling screws.
- Route the EAGLE Harness through the pass-thru on the sensor.
- Mount sensor to accessory.
- Wire the EAGLE Harness to the sensor.
CAMERA TECHNICAL SPECIFICATIONS
Voltage regulator
(built into wire harness):
| 6.6 – 36 VDC (±10%)
6 – 28 VAC (±10%)
---|---
Operating temperature:| -30 – 60 °C (max. RH: 95%)
Video output:| 1.0 (Vp-p) / 75Ω
Image Sensor:| CMOS
Horizontal resolution:| 480 TVL
NTSC output:| 720 (H) × 480 (V)
Sync system:| Inter-Sync
Frame rate:| 30 fps
Min. illumination:| 0.01 LUX
AE control:| auto
Gain control:| auto
Elec. shutter:| 1 s ~ 1/10,000 s
S/N ratio:| > 50 dB
AWB:| auto
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
- BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
- BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.
- Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
- Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
- Verify that all appropriate industry signage, warning labels, and placards are in place.
QR SCAN
Visit website for available languages of this document.
Contact
- Tech Support & Customer Service: 1-800-523-2462
- General Tech Questions: techservices-us@BEAsensors.com
- Tech Docs: www.BEAsensors.com
©BEA | Original Instructions
75.5981.04 EAGLE FAMILY ACCESSORIES 20230408