Desoutter 6159360730 Stacklight Industrial Tools User Manual

June 13, 2024
Desoutter

Desoutter logoDesoutter logo2 Part no 6159931370
Issue no 08
Stacklight:6159360730
www.desouttertools.com

Desoutter 6159360730 Stacklight Industrial Tools

Find more information and your Desoutter contacts on: www.desouttertools.com
Software and documentation available at:https://www.desouttertools.com /resource-centre
Exploded views and spare parts lists are available in “Service Link” at:www.desouttertools.com

Original instructions.
© Copyright 2022, Ets Georges Renault 44818 St Herblain, FR
All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings. Use only authorized parts. Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability.

STATEMENT OF USE

This stacklight is designed for operator’s guidance and is to be connected to the eBUS port of the Desoutter CVI3 range of controllers.
No other use will be permitted.
For professional use only.

ON RECEIVING THE STACKLIGHT

  • Check the following items are included in the packing box:Desoutter 6159360730 Stacklight Industrial Tools - packing box

Legend

  1. Stacklight
  2. 2 DIN Rail holders + 4 screws
  3. Termination plug SubD 9 pt
  4. 2 mounting plates
  5. 2 screws M4x10
  6. Stacklight keys

OVERALL DIMENSIONS IN MM

Desoutter 6159360730 Stacklight Industrial Tools - OVERALL
DIMENSIONS

MOUNTING

Wall mounting

  • Secure the stacklight as shown below by using 2 M6 screws (not supplied in the kit).Desoutter 6159360730 Stacklight Industrial Tools -

Mounting on DIN rail

The stacklight is designed to be mounted on an Ω-type DIN rail.
DIN rail TS 35
Length: 115 mm minimum

  • First position the 2 holders on the stacklight as shown below by using the 4 self tapping screws supplied in the kit.
  • Clip the stacklight on the rail.

Mounting on aluminium profile

  • First position the 2 mounting plates on the stacklight as shown below by using the 2 screws supplied in the kit.
  • Mount the stacklight on the aluminium profile.Desoutter 6159360730 Stacklight Industrial Tools - aluminium profil

STACKLIGHT CONNECTION

Desoutter 6159360730 Stacklight Industrial Tools - STACKLIGHT
CONNECTION

Legend

  1. eBUS cable connection
  2. Termination plug SubD-9pt
    Put the termination plug when:

– the stacklight is unique on the eBUS network.
– the stacklight is the last accessory on the eBUS network.

STACKLIGHT POSITION

  • Remove the cap from the encoding wheel.

  • By using a screwdriver, select the position number of the stacklight on the eBUS cable.
    (1-9 and A-F) 1 being the first position, F the last (F=15).

  • Put the cap back on the wheel.

CONTROLLER CONNECTION

  • Connect the eBUS cable to the bottom panel of the controller (see below).

24V-1A is supplied from the controller to power the stacklight.
Max current: 270 mA @ 24V DC

FRONT PANEL

Desoutter 6159360730 Stacklight Industrial Tools - FRONT
PANEL

Legend

  1. Encoding wheel
  2. Push-button
  3. Label dedicated to the push-button
  4. Key with 2 positions: left/right
  5. Label dedicated to the key
  6. Power LED
  7. Buzzer

LABELING

Disassembly

  • Loosen the 4 screws on the left side of the stacklight as shown below.
  • Remove the labels and write the description with a pencil.

Reassembly

Ensure that the seal is correctly mounted.

  • Add some glue and tighten the screws as shown below:Desoutter 6159360730 Stacklight Industrial Tools - screws

CUSTOMIZING THE LEDS

Colors by default

Desoutter 6159360730 Stacklight Industrial Tools - Colors by
default Legend

  1. Red
  2. Orange
  3. Green
  4. Blue

How to change the order

  • Remove each LED by unscrewing a 1/4 turn right.
  • Reassemble the LEDs in the desired order.
  • Put the cap back on the top.

STACKLIGHT CONFIGURATION

You will need CVI CONFIG software to configure the stacklight.

  • Refer to chapter “I/O and accessories” in CVI CONFIG user manual.
    Inputs
    There are 3 inputs:
    – Push-button
    – Key – right position
    – Key – left position

  • Assign an input event to each input.
    Outputs
    There are 5 outputs:
    – Lamp 4
    – Lamp 3
    – Lamp 2
    – Lamp 1
    – Buzzer

  • Assign an output event to each output.

Changing output settings can affect actuators connected to the controller.

Name and content of harmful substances in products
DECLARATION OF CONFORMITY

We :
Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France
declare under our sole responsibility that the product(s):
Machine type(s) :

Technical file available from EU headquarter.
P.Roussy, R&D Manager
Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France
CONTROLLER

Model (a) P/N Model P/N
CVI3 Essential (a) 6159326950 TWINCVI3 E-STOP   (a) 6159326980
CVI3 Function (a) 6159326900 BIT TRAY  (b) 6159360800
CVI3 Vision (a) 6159326910 SOCKET TRAY  (b) 6159360710
TWINCVI3 (a) 6159326970 STACK LIGHT (a) 6159360730
CVI3 Function E-STOP (a) 6159326930 OPERATOR PANEL (a) 6159360720
CVI3 Vision  E-STOP 6159326940 IO EXPANDER (a) 6159360740

Origin of the product : (a) Slovakia (b) Estonia
is in conformity with the following UK Regulations :
to “Electrical Equipment (Safety) Regulations 2016”
to “Electromagnetic Compatibility Regulations 2016”
to “The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012”
Designated standard(s) applied :
EN 61010-1:2010 + A1 :2019
EN 61326-1:2013 (Class A /Industrial)
NAME and POSITION of issuer :
Place & date : Saint-Herblain, 03/02/2022
Pascal ROUSSY
( R&D Manager)

Contact :
UK Authorized Representative :| Air Compressors & Tools Ltd
Zodiac – Unit 4
Boundary way
Hemel Hempstead Industrial Estate
HP27SJ Hempstead
Hertfordshire – UK
M.Taylor
---|---

(2) We :
(3) Technical file available from EU headquarter.
(4) declare under our sole responsibility that the product(s):
(5) Machine type(s) :

Model
(Modele)| | Part
Number
(Reference)| Voltage
(Tension)
---|---|---|---
CVI3 Essential| (a)| 6159326950| 100 — 240| V
CVI3 Function| (a)| 6159326900| 100 — 240| V
CVI3 Vision| (a)| 6159326910| 100 — 240| V
TWINCVI3| (a)| 6159326970| 100 — 240| V
CVI3 Function — ESTOP(a)| 6159326930| 100 — 240| V
CVI3 Vision — ESTOP| (a)| 6159326940| 100 — 240| Vr
TWINCVI3 — ESTOP| (a)| 6159326980| 100 — 240| Vr
BIT TRAY| (b)| 6159360800| 24|
V
SOCKET TRAY| (b)| 6159360710| 24|
V
STACK LIGHT| (a)| 6159360730| 24|
V
OPERATOR PANEL| (a)| 6159360720| 24|
V
I/O EXPANDER| (a)| 6159360740| 24|
V

(6) Origin of the product : (a) : Slovakia (b) : Estonia
(7) is in conformity with the requirements of the council Directives on the approximation of the laws of the Member States relating :
(9) to “Electromagnetic Compatibility” 2014/30/EU (26/02/2014)
(10) to “Low voltage” 2014/35/EU (26/02/2014)
(14) to “The Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment” 2011/65/EU (08/06/2011)
(11) applicable harmonized standard(s) :
(12) NAME and POSITION of issuer :
(13) Place & date : Saint Herblain, 30/07/2021
EN 61010-1:2010
EN 61326-1:2013 (Class A /Industrial)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals