Desoutter 6159360720 Operator Panel
Product Information
The Operator Panel is a flexible lamp and switch box designed to interface with controllers of the Desoutter CVI3 range. It is to be connected to the eBUS port of the controllers. The panel is for professional use only.
Optional Accessories
Description | Color | Type Number | Part Number | Information |
---|---|---|---|---|
Key switch Lamp | – | K1 | LR, LG, LY, LBLU | All keys have the same coding. No |
LED lamp is used together
with a key switch.
Selector switch| Black| S1BLK| 6159390420|
Illuminated push-button| Red, Green, Yellow, White| P1R, P1G, P1Y, P1W|
6159390360, 6159390350, 6159390370, 6159390340|
Push-button| –| P2R, P2G, P2Y, P2W, B1| 6159390360, 6159390350, 6159390370,
6159390340| Pushbutton with raised button with holder black.
Blanking plug| –| –| –| The blanking plug is for covering not used positions.
LED-lamp| Red, Green, Yellow, White, Blue| –| 6159390275, 6159390470,
6159390450, 6159390440, 6159390430,
6159390460| The LED lamps are used together with a lamp, switch or button
with corresponding color.
eBUS cable| –| –| 6159390300, 6159176070, 6159176080, 6159176090, 6159176100|
1m, 3m, 5m, 15m
eBUS termination plug| –| –| 6159176250| Wedge base 24 V DC
Overall Dimensions (in mm)
- Width: 244.80 mm
- Height: 208.20 mm
- Depth: 117.70 mm
- Mounting Plate Thickness: 14.50 mm
Mounting Instructions
Wall Mounting:
- Secure the operator panel as shown below by using 2 M6 screws (not supplied in the kit).
Mounting on DIN Rail:
The operator panel is designed to be mounted on an Ω-type DIN rail. DIN rail
TS 35
Length: 115 mm minimum
- First, position the 2 holders on the operator panel using the 2 self-tapping screws supplied in the kit.
- Mount the operator panel on a DIN rail of type TS 35 with a minimum length of 115 mm.
- Clip the operator panel on the rail.
Mounting on aluminium profile
- First position the 2 mounting plates on the operator panel as shown below by using the 2 screws supplied in the kit.
- Mount the operator panel on the aluminium profile.
OPERATOR PANEL CONNECTION
Legend
- eBUS cable connection
- Termination plug SubD 9-pt
Put the termination plug when:
- The operator panel is unique on the eBUS network.
- The operator panel is the last accessory on the eBUS network.
CONTROLLER CONNECTION
- Connect the eBUS cable to the bottom panel of the controller (see below).
- 24V-1A is supplied from the controller to power the operator panel.
Legend
Controller eBUS port
Max current: 110 mA @ 24V DC.
OPERATOR PANEL POSITION
Legend
- Encoding wheels location
- Address encoding wheel
- Unused switch
- Remove the front panel.
- On the address encoding wheel, use a screwdriver to select the position number of the operator panel on the eBUS cable: (1-9 and A-F), 1 being the first position, F the last (F=15).
- Do not change the position of the unused switch (set to 0).
LABELING
Disassembly
- Loosen the screws of the left side and of the front panel as shown below.
- Remove the labels and write the description with a pencil.
Reassembly
- Ensure that the seal is correctly mounted.
- Add some glue and tighten the screws as shown below.
OPERATOR PANEL CONFIGURATION
You will need CVI CONFIG software to configure the operator panel.
- Refer to CVI CONFIG user manual.
Name and content of harmful substances in products
Original instructions.
© Copyright 2022, Ets Georges Renault 44818 St Herblain, FR
All rights reserved. Any unauthorized use or copying of the contents or part
thereof is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized parts. Any
damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
STATEMENT OF USE
The operator panel is a flexible lamp and switch box designed to interface
with controllers of the Desoutter CVI3 range and is to be connected to the
eBUS port of the controllers. No other use will be permitted. For professional
use only.
ON RECEIVING THE OPERATOR PANEL
- Check the following items are included in the packing box:
Legend
- Operator panel
- Termination plug SubD 9-pt
- Support rails DIN TSH 35-2
- Mounting plate accessories
- 2 screws M4x10
DECLARATION OF CONFORMITY
We :
Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France
Technical file available from EU headquarter.
P.Roussy, R&D Manager
Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France
declare under our sole responsibility that the product(s):
Machine type(s) :
- Model: P/N
- CVI3 Essential
- (a) 6159326950
- CVI3 Function
- (a) 6159326900
- CVI3 Vision
- (a) 6159326910
- TWINCVI3
- 6159326970
- CVI3 Function E-STOP
- 6159326930
- CVI3 Vision E-STOP
- (a) 6159326940
CONTROLLER
- Model: P/N
- TWINCVI3 E-STOP
- (a) 6159326980
- BIT TRAY
- (b) 6159360800
- SOCKET TRAY
- (b) 6159360710
- STACK LIGHT
- (a) 6159360730
- OPERATOR PANEL
- (a) 6159360720
- IO EXPANDER
- (a) 6159360740
Origin of the product :
- Slovakia
- Estonia is in conformity with the following UK Regulations :
- to “Electrical Equipment (Safety) Regulations 2016”
- to “Electromagnetic Compatibility Regulations 2016”
- to “The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012”
Designated standard(s) applied :
- EN 61010-1:2010 + A1 :2019
- EN 61326-1:2013 (Class A /Industrial)
NAME and POSITION of issuer :
Pascal ROUSSY ( R&D Manager)
Place & date : Saint-Herblain, 03/02/2022
UK Authorized Representative :
Air Compressors & Tools Ltd
Zodiac – Unit 4
Boundary way
Hemel Hempstead Industrial Estate
HP27SJ Hempstead
Hertfordshire – UK
M.Taylor
Find more information and your Desoutter contacts on:
www.desouttertools.com
Software and documentation available at:
https://www.desouttertools.com/resource-centre
Exploded views and spare parts lists are available in “Service Link” at:
www.desouttertools.com
References
- Desoutter Industrial Tools - Industrial Pneumatic Tool for Aeronautics & Automotive
- Technical Documentation for Industrial Tools - Desoutter Industrial Tools
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>