Desoutter 6159360720 Operator Panel User Manual

June 13, 2024
Desoutter

Desoutter 6159360720 Operator Panel

Product Information

The Operator Panel is a flexible lamp and switch box designed to interface with controllers of the Desoutter CVI3 range. It is to be connected to the eBUS port of the controllers. The panel is for professional use only.

Optional Accessories
Description Color Type Number Part Number Information
Key switch Lamp K1 LR, LG, LY, LBLU All keys have the same coding. No

LED lamp is used together
with a key switch.
Selector switch| Black| S1BLK| 6159390420|
Illuminated push-button| Red, Green, Yellow, White| P1R, P1G, P1Y, P1W| 6159390360, 6159390350, 6159390370, 6159390340|
Push-button| –| P2R, P2G, P2Y, P2W, B1| 6159390360, 6159390350, 6159390370, 6159390340| Pushbutton with raised button with holder black.
Blanking plug| –| –| –| The blanking plug is for covering not used positions.
LED-lamp| Red, Green, Yellow, White, Blue| –| 6159390275, 6159390470, 6159390450, 6159390440, 6159390430,
6159390460| The LED lamps are used together with a lamp, switch or button
with corresponding color.
eBUS cable| –| –| 6159390300, 6159176070, 6159176080, 6159176090, 6159176100| 1m, 3m, 5m, 15m
eBUS termination plug| –| –| 6159176250| Wedge base 24 V DC

Overall Dimensions (in mm)
  • Width: 244.80 mm
  • Height: 208.20 mm
  • Depth: 117.70 mm
  • Mounting Plate Thickness: 14.50 mm

Mounting Instructions

Wall Mounting:

  1. Secure the operator panel as shown below by using 2 M6 screws (not supplied in the kit).

Mounting on DIN Rail:

The operator panel is designed to be mounted on an Ω-type DIN rail. DIN rail TS 35
Length: 115 mm minimum

  1. First, position the 2 holders on the operator panel using the 2 self-tapping screws supplied in the kit.
  2. Mount the operator panel on a DIN rail of type TS 35 with a minimum length of 115 mm.
  3. Clip the operator panel on the rail.

Mounting on aluminium profile

  1. First position the 2 mounting plates on the operator panel as shown below by using the 2 screws supplied in the kit.
  2. Mount the operator panel on the aluminium profile.

OPERATOR PANEL CONNECTION

Legend

  1. eBUS cable connection
  2. Termination plug SubD 9-pt

Put the termination plug when:

  • The operator panel is unique on the eBUS network.
  • The operator panel is the last accessory on the eBUS network.

CONTROLLER CONNECTION

  • Connect the eBUS cable to the bottom panel of the controller (see below).
    • 24V-1A is supplied from the controller to power the operator panel.

Legend
Controller eBUS port
Max current: 110 mA @ 24V DC.

OPERATOR PANEL POSITION

Legend

  1. Encoding wheels location
  2. Address encoding wheel
  3. Unused switch
    • Remove the front panel.
    • On the address encoding wheel, use a screwdriver to select the position number of the operator panel on the eBUS cable: (1-9 and A-F), 1 being the first position, F the last (F=15).
    • Do not change the position of the unused switch (set to 0).

LABELING

Disassembly

  • Loosen the screws of the left side and of the front panel as shown below.
  • Remove the labels and write the description with a pencil.

Reassembly

  • Ensure that the seal is correctly mounted.
  • Add some glue and tighten the screws as shown below.

OPERATOR PANEL CONFIGURATION
You will need CVI CONFIG software to configure the operator panel.

  • Refer to CVI CONFIG user manual.

Name and content of harmful substances in products

Desoutter-6159360720
-Operator-Panel-fig- \(13\)

Original instructions.

© Copyright 2022, Ets Georges Renault 44818 St Herblain, FR
All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings. Use only authorized parts. Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability.

STATEMENT OF USE
The operator panel is a flexible lamp and switch box designed to interface with controllers of the Desoutter CVI3 range and is to be connected to the eBUS port of the controllers. No other use will be permitted. For professional use only.

ON RECEIVING THE OPERATOR PANEL

  • Check the following items are included in the packing box:

Legend

  1. Operator panel
  2. Termination plug SubD 9-pt
  3. Support rails DIN TSH 35-2
  4. Mounting plate accessories
  5. 2 screws M4x10

DECLARATION OF CONFORMITY

We :

Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France

Technical file available from EU headquarter.

P.Roussy, R&D Manager
Ets Georges Renault
38 rue Bobby Sands – BP 10273
44818 Saint Herblain – France

declare under our sole responsibility that the product(s):

Machine type(s) :

  • Model: P/N
  • CVI3 Essential
    • (a) 6159326950
  • CVI3 Function
    • (a) 6159326900
  • CVI3 Vision
    • (a) 6159326910
  • TWINCVI3
    • 6159326970
  • CVI3 Function E-STOP
    • 6159326930
  • CVI3 Vision E-STOP
    • (a) 6159326940

CONTROLLER

  • Model: P/N
  • TWINCVI3 E-STOP
    • (a) 6159326980
  • BIT TRAY
    • (b) 6159360800
  • SOCKET TRAY
    • (b) 6159360710
  • STACK LIGHT
    • (a) 6159360730
  • OPERATOR PANEL
    • (a) 6159360720
  • IO EXPANDER
    • (a) 6159360740

Origin of the product :

  • Slovakia
  • Estonia is in conformity with the following UK Regulations :
    • to “Electrical Equipment (Safety) Regulations 2016”
    • to “Electromagnetic Compatibility Regulations 2016”
    • to “The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012”

Designated standard(s) applied :

  • EN 61010-1:2010 + A1 :2019
  • EN 61326-1:2013 (Class A /Industrial)

NAME and POSITION of issuer :
Pascal ROUSSY ( R&D Manager)

Place & date : Saint-Herblain, 03/02/2022

UK Authorized Representative :

Air Compressors & Tools Ltd
Zodiac – Unit 4
Boundary way
Hemel Hempstead Industrial Estate
HP27SJ Hempstead
Hertfordshire – UK
M.Taylor

Find more information and your Desoutter contacts on:
www.desouttertools.com

Software and documentation available at:
https://www.desouttertools.com/resource-centre

Exploded views and spare parts lists are available in “Service Link” at:
www.desouttertools.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals