Instructions for use

Dimension

Application
Unshielded wall luminaire with crystal glass. The integrated passive infrared motion and light sensor responds to heat emission in the dark and therefore activates in case of human or animal movement in the vicinity of the luminaire. Configuration is done via Bluetooth and the free BEGA Tool app

Lamp
Module connected wattage: 23.9 W
Luminaire connected wattage : 27.5 W
Rated temperature : ta=25 °C
Ambient temperature : ta max=40 °C

24 568K3
Module designation : LED-0993/830
Colour temperature : 3000 K
Colour rendering index : CRI >80
Module luminous flux : 3975 lm
Luminaire luminous flux : 2651 lm
Luminaire luminous efficiency: 96,4 lm/W

24 568K4
Module designation : LED-0993/840
Colour temperature: 4000 K
Colour rendering index: CRI >80
Module luminous flux: 4180 lm
Luminaire luminous flux : 2788 lm
Luminaire luminous efficiency: 101,4 lm/W

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Crystal glass, white inside 2 mounting holes ø 4.5mm
  • Distance apart 325mm 2 screw cable glands with strain relief for through-wiring power connecting cable ø 7–12mm 1 screw cable gland closed at the factory with a dummy plug
  • Connection terminal 0,5-2,5@
  • Earth conductor connection
  • Passive infrared motion sensor (PIR)
  • Range up to 10m
  • Horizontal opening angle 110°
  • Vertical opening angle 93°
  • Minimum temperature difference between moving object and environment 4 °C
  • Object speed ideally 1m/s
  • Adjustable sensitivity of the motion sensor (inertia)
  • Shut-down delay adjustable between 5s and 240min
  • Light sensor: adjustable value range from darkness to approaching dusk (approx. 150lx)
  • Fixed pre-set time hysteresis for suppression of undesired switching operations in luminaires during rapid brightness fluctuations
  • Luminaire dimmable (0 to 100%)
  • Adjustable basic brightness
  • Luminaire can be switched on and off with a non-adjustable soft start function (1s) or directly to the set brightness value
  • Transmission frequency range: 2400-2483.5MHz
  • Maximum transmission output: 10mW
  • LED power supply unit 220-240 V y 50-60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shuttdown to protect demperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK05
  • Protection against mechanical impacts < 0.7 joule
  •  Safety mark
  •  Conformity mark
  • Weight: 4.2 kg
  • This product contains light sources of energy efficiency class(es) C, D

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

EU Declaration of Conformity
BEGA Gantenbrink-Leuchten KG hereby declares that the radio system type 24 568 complies with Directive 2014/53/EU (RED). The complete text of the EU Declaration of Conformity is available at the following Internet address : https://www.bega.com/conf/de/24568

Installation
Undo hexagon socket head screw (wrench size 3mm) through the opening in the luminaire housing up to the stop and lift luminaire top. Disconnect the earth conductor connection from the plug connection. Disconnect plug-connection of the LED connecting cable.

Orientation of the sensor
The sensor is factory-configured for the maximum detection area. In order to avoid the unintentional adjustment of the sensor in public areas, the alteration of the factory setting must be made before the luminaire base is mounted. To do so, loosen the two rear screws (Torx driver T10) slightly and rotate the sensor ball to the desired position (see Fig. A ).
Tighten The Mounting Screws

 Lead the mains supply cable through the screw cable gland into the luminaire back housing. Notice position of use “arrow down” of the luminaire back plate. The installed black gasket insert is intended for cables ø < 10mm. For cables ø 10-12mm the enclosed grey gasket insert must be used. In case of through- wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert. At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch)
Wire

 Notice position of use “arrow down” of the luminaire back plate. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Tighten screw cable gland. Make the earth conductor connection and the electrical connection. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Connect the LED connection cable by means of a plug connector. Make earth conductor connection between luminaire top and luminaire base. Push plug into coupler as far as it will go.

Make sure that gasket is positioned correctly. Install luminaire top and tighten.

Commissioning
The power supply must be connected for the commissioning of the luminaire. The brightness sensor will need up to 10 minutes after activation of the power supply to correctly calibrate the brightness value.

Once installed, the luminaire can be operated immediately in its factory settings; configuration via smartphone will not be required.

The factory settings as are follows:

Mode: PIR and light
PIR sensitivity : 100 % (high sensitivity)
Shut-down delay : 5 minutes
Brightness threshold: 40 (approx. 50lx)
Dimming level luminaire: 100 %
Basic brightness : 20 %
Softstart (1s) : active

Alternatively, the integrated PIR motion and light sensor can be configured via smartphone using the free BEGA Tool app. The default values can be reinstated at any time via the BEGA Tool app.

App Herunterladen

bega.com/bega-tool-ios


bega.com/bega-tool-android

Download the app for Android or iOS. Create a project and add the luminaire as your starting point. The individual QR code required for commissioning is enclosed with the luminaire. Please retain the other enclosed QR codes in your on-site documentation (e.g. Instructions for use at top of Page 1). You will also find an additional QR code on the LED module in the luminaire.

The luminaire can only be controlled with the smartphone that was used to configure the sensor. The “Share access” function in the BEGA Tool app grants other smartphones configuration and control rights. The luminaire can be reset to factory settings in the app, if required. Follow the in-app instructions.

Please note:
The integrated light sensor operates with a time delay to prevent responses to short-term brightness fluctuations in the environment of the luminaire. The time delay is around 1 to 3 minutes. A manual darkening of the sensor will therefore not result in an immediate response. Once commissioned successfully, you can choose between three operating modes and one manual control mode.

Operating modes:

  • PIR motion and light sensor
  • PIR motion sensor only
  • Light sensor only

Manual switching:

  • Sensor deactivation and manual control of the luminaire (on/off)

Range / Detection area
The specifications for the range and detection area of the PIR motion sensor are reference values. The detection area is up to 110° horizontally and 93° vertically, with a depth of max. 10m depending on the direction of motion (see sketch). Too minor temperature difference between the moving object and the ambient temperature can influence the detection range. Local conditions and external heat sources may affect both the range and the detection area

Dimension

Reset to factory settings
The luminaire must be switched off five times within 30 seconds for at least 2 seconds each time to manually reset it to factory settings (see sketch). The luminaire can furthermore be reset to the factory settings via the BEGA Tool app. The reset is confirmed with five flashes of the luminaire. The smartphone will be disconnected.
Factory Settings

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire

Please note:
After replacing the LED module, the PIR motion and light sensor of the luminaire must be reconfigured (see section Commissioning). To do so, you must use the QR code enclosed with the replacement module. Please paste the additional enclosed QR codes over the QR codes in documentation provided by the customer.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners

Spares
Spare glass : 11 003 519
LED power supply unit : DEV-0424/48V
Control board BT : 61 001 950
PIR and light sensor: 61 001 951
LED module: 3000
K LED :-0993/830
LED module : 4000
K LED :-0993/840
Gasket glass : 83 001 927