BEGA 23 404.2 Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 23 404.2 Wall Luminaire

Product Usage Instructions

  1. If the luminaire is to be mounted onto a metallic, electroconductive surface, ensure that the mounting surface is connected conductive to the earth conductor of the luminaire.
  2. During installation or relamping, avoid touching the light output opening of the LED directly.
  3. To open the luminaire:
    • Loosen the lateral knob and remove the cap.
    • Take out the glass component and loosen the isolating plug (LED-lines).
  4. Pull silicone sleeves over the wires, make an earth connection, and electrical connection to the terminal.
  5. Mount the luminaire housing with suitable fixing material onto the mounting surface.
  6. Take the glass component and reconnect the isolating plug (LED-lines).
  7. Place the glass component into the luminaire housing, close the luminaire with the cap, and screw in the knob into the cap.

Instructions for use

BEGA-23404-2-Wall-Luminaire-1

Application
Wall luminaire · indoor luminaire made of hand-blown opal glass, with metal housing. The light aperture can be adjusted infinitely by rotating the shield around its longitudinal axis. Light aperture 120°; adjustable.

Product Description

  • Die-cast aluminium and aluminium housing, finish Stainless steel
  • Hand-blown opal glass
  • 2 elongated fixing holes
  • Width 6mm · 100mm spacing
  • Connection terminal 2.5@
  • Earth conductor connection
  • Built-in toggle switch
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
    • Weight: 1.3 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 4.8 W
  • Luminaire connected wattage 5.9 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=45 °C
  • 23 404.2K3
    • Module designation LED-0345/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 790 lm
    • Luminaire luminous flux 296 lm
    • Luminaire luminous efficiency 50,2 lm/W

Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • To open the luminaire:
  • Loosen lateral knob and remove cap. Take out glass component and loosen the isolating plug (LED-lines).
  • Pull silicone sleeves over the wires, make earth connection and electrical connection to the terminal.
  • Mount luminaire housing with suitable fixing material onto the mounting surface.
  • Take the glass component and reconnect the isolating plug (LED lines).
  • Place glass component into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Replacement of the LED module · Maintenance

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Loosen lateral knob and remove cap. Take out glass component and loosen the isolating plug (LED-lines).
  • Clean glass and luminaire regularly with solvent-free cleansers from dirt.
  • Please follow the installation instructions for the LED module.
  • Insert glass component into the light shade and remount the teflon ring.
  • Take the glass component and reconnect the isolating plug (LED-lines).
  • Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.
  • A broken glass must be replaced.

Spares

  • Spare glass 11 003 059 .1M2RG
  • LED power supply unit DEV-0303/350
  • Switch 63 000 360
  • LED module 3000 K LED-0345/930

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals