BEGA 84167 Floodlight With Symmetrical Light Distribution Instruction Manual

June 12, 2024
BEGA

BEGA 84167 Floodlight With Symmetrical Light Distribution

Product Information

  • The product is a floodlight with symmetrical light distribution. It is designed for recessed mounting in compacted surfaces, paths, and places. It can also be used as a drive-over luminaire for vehicles with pneumatic tires.
  • Please note that the luminaire should not be installed in road lanes where it will be exposed to horizontal strain due to braking, acceleration, and change of direction.
  • The luminaire is made of aluminum alloy, aluminum, and stainless steel. The cover frame is made of stainless steel (steel grade number 1.4301).

It has the following specifications:

  • Safety class: I
  • Protection class: IP 67
  • Pressure load: 1,000 kg (~10 kN)
  • Impact strength: IK09
  • Weight: 14.5 kg
  • Energy efficiency class: C
  • The product also comes with overvoltage protection for the electronic components installed in the luminaire.
  • Separate overvoltage protection components are recommended for additional protection against transients.
  • These components can be found on the manufacturer’s website.

Product Usage Instructions

Prior to installation, ensure that a proper foundation capable of accepting the maximum pressure load of 1,000 kg (~10 kN) is provided by the customer.

To install the luminaire:

  1. Dismantle the luminaire from the recess housing by undoing the screws in the stainless steel frame.
  2. Lift the luminaire out of the recess housing.
  3. Position the recess housing on the foundation and fix it with the enclosed or any other suitable fixing material.
  4. To stabilize the recess housing during foundation preparation, insert the enclosed wooden spacers into the recess housing.

Ensure that the foundation is carried out on a firm subgrade and that proper drainage is provided to allow surface water to drain off. The lacquering of the recess housing must not be damaged.

Dimension

Instructions for use

Application

  • Floodlight with symmetrical light distribution.
  • For recessed mounting in compacted surfaces, paths, and places.
  • Drive-over luminaire for vehicles with pneumatic tyres.

Please note:

  • Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration, and change of direction.

Product Description

  • Luminaire made of aluminum alloy, aluminum, and stainless steel
  • The cover frame is made of stainless steel, steel grade number 1.4301
  • Recess housing with cable entry for cable conduit, max ø 20mm Matt safety glass
  • BEGA Vortex Optics®. Reflector surface made of pure aluminium 1,8m water-resistant connecting cable 07RN8-F 5G1@ with implemented water stopper and 1.2m PVC cable conduit
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • DALI controllable
  • Basic isolation exists between the power cable and the control line
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 67
  • Dust-tight and protection against temporary immersion
  • Pressure load 1,000 kg (~10 kN)
  • Impact strength IK09
  • Protection against mechanical impacts < 10 joule
  • Maximum surface temperature 25 °C (measured according to EN 60598 of a 15 °C)
  • r – Conformity mark
  • Safety mark
  • Weight: 14.5 kg
  • This product contains light sources of energy efficiency class(es) C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Notice prior to installation:

  • To accept the maximum pressure load of 1,000 kg (~10 kN) a proper foundation must be provided by the customer.
  • The luminaire is mounted in a recess housing made of a high-strength aluminum profile.
  • The pressure load is transferred to the foundation by this housing. Foundation to be provided at the site. The foundation must be carried out on a firm subgrade.
  • In order to obtain a firm stableness, the recess housing must be firmly concreted in.
  • During preperation of the foundation, proper drainage must be provided so that entering surface water can drain off.
  • The lacquering of the recess housing must not be damaged.
  • For the tightness of the luminaire it is important that the ground surface (1) prepared later is either on the same level or slightly below the top edge of the recess housing (2) – see sketch (detail A).

Soil Conditions

  • The luminaire must not permanently have contact with aggressive media. Aggressive media might be washed out of the soil and might corrode the housing of the luminaire.
  • In case of an unknown composition of the soil, a soil analysis should be made before installation. Aggressive media that is outgoing from the ground surface might also affect the luminaire. Thus an overuse of de-icing agents in the surroundings should be avoided. Parasitic current, occurring from the outside, can cause corrosion damage at the luminaire. Suitable countermeasures must be carried out.

Installation

  • Dismantle the luminaire from the recess housing.
  • For this purpose undo the screws in the stainless steel frame. Lift the luminaire out of the recess housing.
  • Position recess housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
  • To stabilize the recess housing when preparing the foundation, insert the enclosed wooden spacers into the recess housing.
  • 0.3 m of cable is provided in the installation housing so that the luminaire may be removed.
  • To protect the luminaire connecting the cable from damage push the enclosed cable conduit over the cable.
  • The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
  • We recommend that you use distribution box 70 730 or 71 053 for this purpose.
  • Ensure that the connection cable is correctly connected.
  • Make the mains connection to the brown (L), blue (N), and green-yellow wires (1).
  • The control cables are connected via the two wires marked DALI.
  • If these wires are not assigned, the luminaire will work with full light output.
  • Insert the lamp housing into the outer housing.
  • Tighten locking screws firmly

Lamp

  • Module connected wattage 47.4 W
  • Luminaire connected wattage 53.4 W
  • Rated temperature ta= 25 °C
  • Ambient temperature ta max= 45 °C
  • When installed in heat-insulating material ta max= 40 °C

84 167K27

  • Module designation 6x LED-0771/827
  • Color temperature 2700 K
  • Color rendering index CRI >80
  • Module luminous flux 8580 lm
  • Luminaire luminous flux 5548 lm
  • Luminaire luminous efficiency 103,9 lm/W

84 167K3

  • Module designation 6x LED-0771/830
  • Color temperature 3000 K
  • Color rendering index CRI >80
  • Module luminous flux 8850 lm
  • Luminaire luminous flux 5723 lm
  • Luminaire luminous efficiency 107,2 lm/W

84 167K4

  • Module designation 6x LED-0771/840
  • Color temperature 4000 K
  • Color rendering index CRI >80
  • Module luminous flux 9090 lm
  • Luminaire luminous flux 5885 lm
  • Luminaire luminous efficiency 110,2 lm/W

Light technique

  • Broad-spread light distribution.
  • Half beam angle 55°
  • Maintenance
  • Disconnect the electrical installation.
  • Clean dirt and deposits from key openings of the screw head. Do not use a high-pressure cleaner.
  • Undo counter-sunk screws. Lift the luminaire out of the recess housing and place it with the glass
  • the side facing downwards onto an even and clean underlay.
  • Undo the round nuts (torx drive T25) and lift luminaire housing. Clean the luminaire

Cleaning · Maintenance

  • Remove reflectors from the housing groove carefully.

Replace LED modules:

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Note the installation instructions for the LED module.
  • Replacing the LED power supply unit:
  • To replace the power supply unit, the LED module carrier must be removed from the luminaire housing.
  • Loosen the hexagon socket screws (SW 3) and remove the module carrier from the housing using the two metal pins.
  • Replace the power supply unit.

Please note:

  • Do not remove the desiccant pouch from the luminaire housing.
  • It is needed to remove residual moisture.
  • Insert the LED module carrier into the housing in a diagonally downward direction and push it down until the springs snap into place.
  • Check all screws and threads thoroughly and grease them.
  • Check the gasket and replace, it if necessary.
  • A broken glass must be replaced.
  • The luminaire housing must be completely clean and absolutely dry.
  • Insert reflectors. Ensure that the reflector is positioned correctly in the housing recess.
  • Insert glass with gasket with the stepped side turned upward into the luminaire housing.
  • Make sure that gasket is positioned correctly.
  • Place the cover ring onto the glass step and tighten the round nuts firmly and evenly.
  • Torque = 2.5 Nm.
  • Insert the lamp housing into the outer housing and tighten the locking screws firmly.

Cleaning · Maintenance

  • After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes, and rust film must be completely removed. Never use high-pressure cleaners and cleaning implements made of normal steel, steel brushes, or steel wool because they cause extraneous rust to form.
  • When using stainless steel cleaners, please read the directions carefully.
  • Cleaning agents containing hydrochloric acid and chlorides should never be used.
  • We recommend cleaning the luminaires regularly.

Accessories

  • 70 730 Distribution box for installation in soil with 7 cable entries
  • Connection terminals 5 x 4@

Spares

  • Spare glass 14 001 288
  • LED power supply unit DEV-0159/1050
  • LED module 2700 K LED-0771/827
  • LED module 3000 K LED-0771/830
  • LED module 4000 K LED-0771/840
  • Reflector 6x 76 001 591
  • Gasket 83 001 666. A
  • BEGA Gantenbrink-Leuchten KG
  • Postfach 3160
  • 58689 Menden
  • [email protected]
  • www.bega.com

Documents / Resources

| BEGA 84167 Floodlight With Symmetrical Light Distribution [pdf] Instruction Manual
84167 Floodlight With Symmetrical Light Distribution, 84167, Floodlight With Symmetrical Light Distribution, Symmetrical Light Distribution, Light Distribution, Distribution
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals