RF Dimming Module Installation with 0-10 V-.
Please read before installing Compatible with RadioRA 2 and HomeWorks QS systems
LMJ-5T-DV-B
LMK-5T-DV-B
LMQ-5T-DV-B
LMM-5T-DV-B
LMN-5T-DV-B
0-10 V= – Control Output: 10 V = 60 mA
Compatible with: ANSI E1.3.2001 (R2006), IC 60929 Annex E
Important Notes:
For installation by a qualified electrician in accordance with all local and national electrical codes.
Note: Use copper conductors only.
Check to see that the device type and rating is suitable for the application.
DO NOT install if product has any visible damage.
If moisture or condensation is evident, allow the product to dry completely
before installation.
Operate between 32 °F to 104 °F (0 °C to 40 °C). 0% to 90% humidity, non-
condensing. For indoor use only.
Operation
For System Setup Guide and tools visit: www.lutron.com/RadioRA2 or www.lutron.com/HomeWorksQS
Installation
LMJ-, LMQ- models
Use the supplied conduit nut and wire the module as shown.
120/277 V~ 50/60 Hz (LMJ- model)
220-240 V~ 50/60 Hz (LMQ- model)
If installing unit inside a junction box, please see Application Note #423
For more information: www.lutron.com
LMK-, LMM-, LMN- models
Install in a junction box or marshalling box (optional) using the conduit nut
(provided or with mounting screws (not provided). Please consult local and
national electric codes for proper installation.
220-240 V~ 50/60 Hz
Wiring a Lever-Operated Connector (LMK-)
When wiring lever-operated connectors (3 supplied)
I please use 14 AWG to 12 AWG (2.5 mm? to 4.0 mm?) solid or stranded copper
wire.
Placement:
Dimming Modules must be located within 30 ft (9 m) of an RF signal repeater.
Dimming Modules cannot be controlled by the system until they are programmed
using the system programming software.
Reset Factory Defaults
Note: In some instances it may be necessary to reset the Dimming Module back to its factory default settings.
- Triple-tap the TOGGLE “ ” button, on the Dimming Module and hold until the LED begins to flash slowly.
- Within 3 seconds of flashing, release and triple-tap the TOGGLE “ ” button again and the LED will flash rapidly indicating that the unit has been reset to factory defaults.
Note: Any associations or programming previously set up with the unit will be lost and will need to be re-programmed.
Troubleshooting
WARNING: Shock Hazard. May result in serious injury or death. Turn off power at circuit breaker before installing the unit.
FCC Information
(LMJ- model only)
This device complies with part 15 of the FCC Rules and Industry Canada
license-exempt RSS standards). Operation is subject to the following two
conditions:
- This device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Re-orient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Hereby, Lutron Electronics Co., Inc. declares that the radio equipment type LMK- and LMM- are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.lutron.com/europe/Service- Support/Pages/Technical/CEDeclarationsofConformity.asp
Complies with
ImDA Standards
DA103083
Warranty
For warranty information, please
visitwww.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
www.lutron.com/TechnicalDocumentLibrary/Intl
Warrant.odf Lutron, RadioRA, RadioRA 2, and HomeWorks are trademark or
registered trademarks of Lutron Electronics Co., Inc. in the US and/or other
countries. ©2014-2019 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc. | 7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Customer Assistance | +44,0)20.7702.0657 Europe | +91.124.439.0130 Asia/Middle East | 1.844.LUTRON1 USA/Canada | +1.888.235.2910 Mexico | +1.610.282.3800 Others | +1.610.282.6311 Fax| www.lutron.com/suppor
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>