Danfoss BB012DS Solenoid coil Installation Guide

May 15, 2024
Danfoss

Danfoss BB012DS Solenoid coil

Danfoss BB012DS Solenoid coil

Parts List

  • IP00/PD3 Spade
    Instruction For Use

  • IP65/PD3 IP67/PD4 Cable plug
    Instruction For Use

  • IP67/PD4 Terminal box
    Instruction For Use

  • IP67/PD4 Molded cable
    Instruction For Use

Installation Instruction

Instruction For Use
Instruction For Use
Instruction For Use
Instruction For Use
Instruction For Use
Instruction For Use
Instruction For Use

Technical Specification

Type of control 1
Class of protection Class I
Ambient temperature See Tambien on coil
Voltage variation Voltage tolerances For voltage variation, see print on coil

For voltage tolerances see datasheet, when ordering the coil
Humidity| Only none-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be expected.
Ball pressure test| 200 °C (392 °F)
Impulse withstand voltage| Terminal box Cable Spade| 4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <4000 m (13123 ft)
Plug| 4.0 kV at altitude <2000 m (6561 ft)
3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft)
Overvoltage category| III
Degree of protection IPXX Pollution degree PDX| Enclosure rating according to IEC standard 60529 Pollution degree according to EN 60664-1| IP67 plug| PD4
IP65 plug
IP20 pre attentional IPOD spade| PD3
Installation| Integrated control (picture A – D)
Incorporated control (picture A – D)
Independently mounted control (IP65 and IP67) (picture B – D)
Suitable cable and conductor size for terminal box| 06.6 — 011 mm (00.26 — 00.43 in)
0.75 — 1.5 mm2 (21 — 15 AWG flexible cord)
Suitable cable for cable plug| See datasheet when ordering the coil
Molded cable size Cable conductor size| Ø6.6 mm (00.26 in )
3 x 0.75 mm2 (3 x 0.001 in2)
Molded cable| The supply cord of this control cannot be replaced, if the cord is damaged. The control should be discard­ed
Plugs can be removed/mounted| 10 times
Surface temperature| Independently mounted controls should be sealed of if the coil temperature exceed higher than 85°C

  • Only qualified personnel is allowed to install or maintain this product
  • Disconnect the power when dismounting the coil
  • Avoid direct exposure to alkaline conditions, use in neutral conditions is recommended
  • If the coil is used as independently mounted control, the end-user shall use a plastic cable gland with strain relief
  • Technical specifications are according to EN60730-1.

Customers Support

Visit www.products.danfoss.com for further technical data