Product Data

Output LED Channel Max. 12W
DC Voltage 1
Current 6-42V
Current Accuracy 100-700mA via NFC setting; Min.current gear lower to 0.1mA
Rated Power ±3%( ±1%@Certain load)
Input Voltage Range Max. 12W
Frequency Range 0/50/60Hz
Power Factor (Typ.) > 0.96 @ 230VAC Full load
Total Harmonic THD ≤ 8% (@ full load  / 230VAC)
Distortion >80% @ 230VAC full load
Efficiency (Typ.)  0.1A @ 230VAC
AC Current (Typ.) < 5mA /230VAC
Inrush Current (Typ.) <0.5W
Leakage Current L-N:2KV
Standby Power Consumption 200-240VAC/176-280VDC
Anti Surge Max. 3.96A at 230VAC; 90μs duration
Control Dimming Interface 0.01%-100%@ Max current
Dimming Range Amplitude/CCR dimming
Dimming Method Linear/ Logarithmic optional
Dimming Curve DALI Device Type 6 (DALI consumption < 2mA)/ AC Push
Protection Short Circuit Yes, recovers automatically after fault condition

is removed
Over Current| Yes, recovers automatically after fault condition is removed
Over Temperature| Yes, recovers automatically after temperature drop
Environment| Working Temp.| -25℃ ~ +45℃
Max. Case Temp.| TC=85℃ (Ta=”45℃”)
Working Humidity| 10% ~ 95% RH non-condensing
Storage Temp. & Humidity| -40℃ ~ +80℃, 10% ~ 95% RH
Safety & EMC| Safety Standards| EN61347-1, EN61347-2-13
Withstand Voltage| I/P-O/P: 3.75KVAC
Isolation Resistance| I/P-O/P: 100M Ohms / 500VDC / 25℃ / 70% RH
EMC Emission| En55015, EN61000-3-2, EN61000-3-3
EMC Immunity| En61547, EN61000-4-2,3,4,5,6,8,11
Others| MTBF| 191350H, MIL-HDBK-217F @ 230VAC full load and 25℃ ambient temperature
Dimension| 135x35x20mm (LWH)
Warranty| 5 Years

  • In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2,
  • Built-in DALI-2 interface, DALI DT6 device
  • Dimmable LED driver. Max. output power 12W
  • 100-700mA current selectable via NFC program tool. Min.current gear lower to 0.1mA
  • DALI Address/Group/Scene setting via NFC program tool.
  • Class Ⅱ power supply, full isolated plastic case
  • High power factor and efficiency
  • To switch and dim LED lighting luminaries
  • Amplitude/CCR dimming, smooth and deep dimming
  • Compatible with universal DALI masters that support DT6 commands
  • Error report function
  • IP20 rating, suitable for indoor LED lighting applications
  • 5 years warranty

Safety & Warnings

  • DO NOT install with power applied to the device.
  • DO NOT expose the device to moisture.

Operation

  1. DALI Address
    1 DALI address for 1 channel output are assigned by DALI Master controller automatically, please refer to user manuals of compatible DALI Masters for specific operations. With DALI master With NFC Programming devices

Note

  1. Do wiring according to the wiring diagram and power on the DALI system .
  2. Recommend setting parameters without power-on the DALI devices .
  3. Please make sure your mobile phone has NFC function and enable it .
    Working with “SR NFC Tool” APP
    Step 1: Download the APP (searching “SR NFC Tool” from App Store and Google Play) .
    Then open the APP .

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig2

Note:

  1. Please Make sure that you have enabled NFC function with your mobile phone/ tablet .
  2. Please Make sure that the “NFC position” is matched.
  3. Please do not power on the device before setting.
  4. If you can’t download “SR NFC Tool”. Please contact with us.

Step 2: Add device, and name it as you wish.

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig3

Step 3 : Unlock device, enter parameters configuring page.

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig4

Note:

  1. You have to unlock the device then do some settings
  2. Only when the corresponding function is selected, the function interface will be displayed.
    Step 4: Few parameter interface, you can choose the setting based on your requirements.

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig5

Step 5: After setting, please save the selected configuration via NFC and power on the device.

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig6

Tips

  1. NFC function doesn’t require any power driver.
  2. Many functions can be configured by NFC. Kindly check your desired functions.
  3. All of our DALI drivers are in the best performance within our DALI master/ gateway.

Wiring Diagram

  1. With DALI bus
    1)With single color LED luminarie
    SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig7

  2. With PUSH dimmer
    SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig8

AC Push Function

  1. Click the button to switch ON/OFF
  2. Press and hold down the button to increase or decrease light intensity to desired level and release it, then repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%.

Product Dimension

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig9

Operating window

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver -
fig10

Dimming Curve

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver - MCB Load
Quantity1

Driver Performance

Driver Performance

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver - MCB Load
Quantity3

MCB Load Quantity

Module Number| (peak| Twidth| Max.quantity of LED Driver per MCB
B10 B13 B16 B20 B25 C10 C13 C16 C20 C25 D10 D13 D16 D20 D25
---|---|---|---
SRP-2305N-12CC100-700| 3.96A| 90ps| 37| 49| 60| 75| 94| 63| 81| 100| 125| 156| 80| 104| 128| 160| 200
SRP-2309N-12CCT100-700| 3.96A| 90ps| 37| 49| 60| 75| 94| 63| 81| 100| 125| 156| 80| 104| 128| 160| 200

SUNRICHER SRP 2305N 12CC100 700 DALI DT6 NFC Enabled LED Driver - MCB Load
Quantity

Note:

  1. Those MCB parameters are based on ABB S200 series circuit breakers.
  2. For different brands and models of miniature circuit breakers, the quantity of drivers will have difference.
  3. Please do not exceed the above-mentioned quantity during on-site installation, and the specific load quantity shall be subject to on-site installation.
  4. When the installation environment temperature of MCBs exceeds 30°C or when multiple MCBs are installed side by side, the number of mounted drives will be reduced, which requires recalculation.
  5. Type C MCB’s are strongly recommended to use with LED lighting

Update log

Date Version Update content Update by
9/8/2022 V1.2 Parameter Update Romeo

Note:Subject to change without notice. Please contact us if you have any questions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SUNRICHER User Manuals

Related Manuals