CAL-ROYAL HDESC/HDTSESC Escutcheon Lever or Knob for Exit Device Instruction Manual

June 12, 2024
CAL-ROYAL

INSTALLATION INSTRUCTION FOR HDESC
HDTSESC ESCUTCHEON LEVER
KNOB FOR EXIT DEVICE 

Parts name

CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - parts
name

APPLICATIONS

Single Door With Rim Device Double Door With MullionCAL-ROYAL HDESC
HDTSESC Escutcheon Lever or Knob for Exit Device - assembly
2 Double Door With Rim Device and Surface Vertical Rod Device CAL-ROYAL HDESC HDTSESC Escutcheon
Lever or Knob for Exit Device - assembly 3Double Door With Surface Vertical Rod Device CAL-
ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - assembly
4

SET UP HAND OF LEVER HANDLE

  1. Trim shipped with lever in the neutral (non-handed) position.
  2. Turn lever handle to right or left direction to meet door handing. (Fig.1)
  3. Tighten fixed screw (1), (flat head). (Fig.2)
  4. Tighten handing screws (2), (inside hexagon). (Fig.3)
     Please proceed with ESCUTCHEON TRIM/ EXIT DEVICE INSTRUCTIONS.

CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
1

INSTALL MORTISE CYLINDER

  1. Attach the collar and mortise cylinder to the ESC case with mortise nut.(Fig.3)
  2. Position cylinder cam & install cylinder fixing spring as shown.(Fig.4)
  3. Install back cover and mounting posts with provided screws.(Fig.5)

CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
2

MARK AND MOUNTING HOLES FOR ESCUTCHEON TRIM

  1. Mark horizontal centerline by matching to the exit device centerline, which can be found from the exit device template.
  2. Refer to Application Section on page 1 to determine the location of the vertical centerline. Apply trim TEMPLATE to door refer to vertical centerline, which should match exit device vertical centerline located on push side of door.
  3. Mark and drill 25/64″(#10.0mm) holes for mounting posts as shown on template.(Fig.6)
  4. Mark and drill 1″($25.4mm) holes for the trim actuator shaft, which mate with the exit device. See exit device instructions for details.(Fig.6)
    CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
3

INSTALL ESCUTCHEON TRIM

  1. Confirm door thickness 1-3/4″(45mm) or 2-1/4″(58mm), adjust actuating shaft length as (Fig.7 & Fig.8) shown
  2. Insert trim mounting posts and actuating shaft through door.
  3. Mate trim actuating shaft with cam on back of exit device.
  4. Fasten the trim from exit device mounting plate on outside face of door with provided screws.
  5. Test installation by rotating lever handle or key to verify trim activates exit device.
    NOTE: Dummy trim is only for pulling door,handle does not rotate.
    CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
4

HEAVY DUTY ESCUTCHEON LEVER TRIM – LONG ESCUTCHEON TYPE

CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
5|
---|---
Key Locks/Unlocks Lever| No Cylinder Locks Always Active
Entrance ANSI Function 08| Passage ANSI Function 14
CAL-ROYAL HDESC HDTSESC Escutcheon Lever or Knob for Exit Device - fig
7| CAL-ROYAL HDESC HDTSESC
Escutcheon Lever or Knob for Exit Device - fig 8
Dummy Trim| Key Unlocks Lever
Dummy ANSI Function 02| Entrance ANSI Function 03