MEAN WELL EPP-300 series 300W Single Output with PFC Function User Manual

October 26, 2023
MEAN WELL

MEAN WELL EPP-300 series 300W Single Output with PFC Function User Manual
MEAN WELL EPP-300 series 300W Single Output with PFC
Function

Features

Say Goodbye to Motor Burnout: 11 Ti...

Say Goodbye to Motor Burnout: 11 Tips From an Electrical Engineer

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 93%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in 12V/0.5A auxiliary output
  • 5″x3″ compact size
  • Free air convection for 200W and 300W with 20.5 CFM forced air
  • With power good and fail signal output
  • Built-in remote sense function
  • No load power consumption under 0.5W by PS-ON control
  • Standby 5V@1A with fan, @ 0.6A without fan
  • Operating altitude up to 5000 meters
  • 3 years warranty
    Symbols

SPECIFICATION

MODEL| EPP-300-12| EPP-300-15| EPP-300-24| EPP-300-27| EPP-300-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V
RATED CURRENT (20.5CFM)| 25A| 20A| 12.5A| 11.12A| 6.25A
CURRENT RANGE (convection)| 0 ~ 16.67A| 0 ~ 13.33A| 0 ~ 8.33A| 0 ~ 7.4A| 0 ~ 4.17A
CURRENT RANGE (20.5CFM)| 0 ~ 25A| 0 ~ 20A| 0 ~ 12.5A| 0 ~ 11.12A| 0 ~ 6.25A
RATED POWER (convection)| 200W| 200W| 199.9W| 199.8W| 200.2W
RATED POWER (20.5CFM)| 300W| 300W| 300W| 300.24W| 300W
RIPPLE & NOISE (max.)   Note.2| 120mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| Main output:11.4 ~ 12.6V| Main output:14.25 ~ 15.75V| Main output:22.8 ~ 25.2V| Main output:25.65 ~ 28.35V| Main output:45.6 ~ 50.4V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 2500ms, 30ms/230VAC 3000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 13ms/230VAC/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.93/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 90%| 90%| 92.5%| 93%| 93%
AC CURRENT (Typ.)| 3.5A/115VAC 1.8A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC 80A/230VAC
LEAKAGE CURRENT| <2mA/240VAC
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.5 ~ 15V| 16.2 ~ 18.5V| 26 ~ 30V| 29.5 ~ 33.5V| 52 ~ 59.5V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 110℃±5℃ (TSW1) detect on heatsink of power transistor
115±5℃ (12V,15V),85±5℃ (24V,27V,48V) (TSW2) detect on heatsink of output diode
Protection type:  (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down
Protection type: (TSW2)Shut down o/p voltage, re-power on to recover
FUNCTION| 5V STANDBY| 5VSB : 5V@0.6A without fan, 1A with fan 20.5CFM ; tolerance ± 2%, ripple : 150mVp-p(max.)
AUXILIARY POWER (AUX)| 12V@0.5A for driving a fan ; tolerance -15% ~ +10%
PS-ON INPUT SIGNAL| Power on: PS-ON = “Hi” or ” > 2 ~ 5V” ; Power off: PS-ON = “Low” or ” < 0 ~ 0.5V”
POWER GOOD / POWER FAIL| 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃ , 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃ )
OPERATING ALTITUDE Note.7| 5000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC **(Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC      O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32),Conduction Class B,Radiation Class B;BS EN/EN61000-3-2,3;EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN60601-1-2, criteria A, EAC  TP  TC  020
OTHERS| MTBF| 160Khrs min. MIL-HDBK-217F (25℃ )
DIMENSION| 12776.235mm (LWH)
PACKING| 0.37 Kg;   36pcs/14.3Kg/0.96CUFT;
NOTE**|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. Heat Sink HS1,HS2 can not be shorted.
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Mechanical Specification

Product Dimension
Grounding required: The grounding of the system level unit has to connect with Pin No.5 on CN1 of EPP-300 so as to pass EMI
Product Dimension

HS1,HS2 can not be shorted

Unit: mm
AC Input Connector (CN1): JST B5P-VH or equivalent

Pin No.

| Assignment| Mating Housing|

Terminal

---|---|---|---

1

| AC/N| JST VHR or equivalent|

JST SVH-21T-P1.1 or equivalent

24,

| No Pin
3|

AC/L

5

|

FG

DC Output Connector (CN2,CN3)

Pin No.

| Assignment|

Output Terminals

---|---|---
CN2| -V| M3.5 Pan HD screw in 2 positions Torque to 8 lbs-in(90cNm)max.
CN3| +V

Function Connector(CN100):HRS DF11-4DP-2DS or equivalent

Pin No.

| Status| Mating Housing|

Terminal

---|---|---|---
1| -S| HRS DF11-4DS or equivalent| HRS DF11 **SC or equivalent
2| +S
3| DC COM
4| PG

Function Connector(CN951): HRS DF11-4DP-2DS or equivalent

Pin No.| Status| Mating Housing|

Terminal

---|---|---|---
1| 5VSB| HRS DF11-4DS or equivalent| HRS DF1**SC or equivalent
2,4| DC COM
3| PS-ON

FAN Connector(CN952): JST S2B-XH or equivalent

Pin No.

| Assignment| Mating Housing|

Terminal

---|---|---|---
1| DC COM| JST XHP or equivalent| JST SXH-001T-P0.6 or equivalent
2| +12V

Block Diagram

Block Diagram

PFC fosc: 65KHz
PWM fosc: 70KHz

Derating Curve
Derating Curve

Output Derating VS Input Voltage
Voltage Graph

Documents / Resources

| MEAN WELL EPP-300 series 300W Single Output with PFC Function [pdf] User Manual
EPP-300 series, 300W Single Output with PFC Function, EPP-300 series 300W Single Output with PFC Function, Output with PFC Function, PFC Function, Function
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals