  1. Before starting the installation, ensure that the power is shut off at the fuse or circuit breaker.
  2. Consult the local electrical codes to understand the wiring and grounding requirements specific to your area.
  3. Follow the steps below for proper installation:
  4. Turn off the power at the circuit breaker box and remove the old fixture and all hardware from the Outlet Box. Unpack the new fixture carefully and lay out all the parts on a clear area. Take care not to lose any small parts required for installation.
  5. Thread the two Mounting Screws into the pre-drilled holes in the Mounting Plate, spacing them the same distance apart as the holes in the Canopy. Attach the Mounting Plate to the Outlet Box using the two Outlet Box Screws. Ensure that the side of the Mounting Plate marked GND is facing out.
  6. This lamp body consists of 8pcs Pipes that can be connected to achieve various heights. Measure and determine the correct number of Pipes required for your installation. Feed the wires and Safety Cable from the Lamp Holder through each Pipe, Frame, and Pipe. Connect the Pipe to the thread nipple from the Lamp Holder. Thread the thread nipple inside each Pipe and connect all the Pipes and Canopy together until secure. Feed the Safety Cable through the small holes in the side of the Column Nut and lock it securely with the screws.
  7. Take the lamp body assembly to the ceiling Outlet Box and connect the electrical wires. Note: When making wire connections, attach the fixture ground wire to the supply ground wire using a wire nut or attach them to the mounting plate with a green ground screw.

NOTE: BEFORE INSTALLING, CONSULT LOCAL ELECTRICAL CODES FOR WIRING AND GROUNDING REQUIREMENT

Installation Steps

  1.  Shut off the power at the circuit breaker box. Remove the old fixture and all hardware from Outlet Box.

  2. Carefully unpack your new fixture and lay out all the parts in a clear area. Take care not to lose any small parts necessary for installation.

  3. Thread the two Mounting Screws into the pre-drilled holes in the Mounting Plate spaced the same distance apart as the holes in the Canopy. Attach the Mounting Plate to the Outlet Box with the two Outlet Box Screws as shown. The side of the Mounting Plate marked “GND” must face out.

  4. This lamp body includes 8pcs Pipes to be connected to various heights. Measure and determine the correct number of Pipes required. Feed the wires and Safety Cable from Lamp Holder through Pipe, Frame, and Pipes, and connect the Pipe to the threaded nipple from Lamp Holder. Thread the threaded nipple to the inside of each Pipe, and connect all the Pipes and Canopy together until secure. Feed the Safety Cable through the small holes in the side of the Column Nut, and lock it securely with the screws.

  5. Take this lamp body assembly to the ceiling Outlet Box, and connect the electrical wires.

  6. NOTE : make wires connections:

  7. Attach fixture ground wire to supply ground wire using a wire nut or attach them to the mounting plate with a green ground screw.

  8. Attach fixture white wire from the lamp body to supply white wire or ridge wire from a power source with a wire nut.

  9. Attach fixture black wire from the lamp body to supply black wire or smooth wire from a power source with a wire nut.

  10. Observing: positive wire with positive wire, negative wire with negative wire, ground wire with ground wire.

  11. Make sure all wire connectors are secured and do not easily pull off with a slight tug. After the wires are connected, tuck them carefully inside the Outlet Box. Raise the Canopy on to the Outlet Box, align screws on Mounting Plate with mounting holes in Canopy, and lock it securely with the Finials.

  12. Install the light bulbs(Not included) in accordance with the fixture’s specifications.
    NOTE : DO NOT EXCEED THE MAXIMUM WATTAGE RATING!

  13. Raise the Glass Sheet to the Frame side and use Handle Screw to secure Glass Sheet as well as Plastic Shim onto Frame. Note: handle screws do not lock too tightly!

  14. Your installation is now complete. Return power to the outlet box and test the lamp body.