ADLER AD 7852 Automatic / Cool / Dry / Fan User Manual

June 6, 2024
ADLER

AD 7852
user manual

|
---|---

|
---|---

SAFETY CONDITIONS. IMPORTANT INSTRUCTIONS ON SAFETY OF USE PLEASE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

  1. Before using the device, read the operating manual and follow the instructions contained in it. The manufacturer is not liable for damages caused by using the device contrary to its intended purpose or improper operation.

  2. The device is for home use only. Do not use for other purposes that are not for its intended purpose.

  3. The device should only be connected to an AC outlet with a grounded 220 240V ~ 50Hz. To increase operational safety, multiple electrical devices should not be
    connected to one current circuit at the same time.

  4. Use extreme caution when using the device when children are nearby. Do not allow children to play with the device, do not allow children or people unfamiliar with the device to use it.

  5. WARNING: This equipment may be used by children over 8 years of age and people with limited physical, sensory or mental ability, or people who have no experience or knowledge of the equipment, if this is done under the supervision of a person responsible for their safety or have been granted them information on the safe use of the device and are aware of the dangers of using it. Children should not play with the equipment. Cleaning and maintenance of the device should not be performed by children unless they are over 8 years old and these activities are carried out under supervision.

  6.  Always disconnect the power plug by holding the socket with your hand after use. DO NOT pull on the power cord.

  7. Do not immerse the cable, plug, and the whole device in water or any other liquid. Do not expose the device to atmospheric conditions (rain, sun, etc.) or use it in conditions of high humidity (bathrooms, damp mobile homes).

  8. Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialist repair shop to avoid danger.

  9. Do not use the appliance with a damaged power cord or if it has been dropped or damaged in any other way or if it is not working properly. Do not repair the device yourself, as there is a risk of electric shock. Take the damaged device to an appropriate service center for checking or repair. All repairs may only be carried out by authorized service points. Incorrectly performed repairs can cause serious danger for the user.

  10. Place the device on a cool, stable surface, away from hot kitchen appliances such as an electric stove, gas burner, etc.

  11. Make sure that nothing is blocking the air inlet and outlet of the device

  12. Use the device only on a level surface to prevent the condensation from spilling out

  13. To provide additional protection, it is advisable to install a residual current device (RCD) in the electric circuit with a rated residual current not exceeding 30mA. Ask an electrician for this.

  14. Clean the air filter regularly. The frequency of cleaning depends on the cleanliness of the air.

  15. After turning off the machine, wait at least 5 minutes before turning it back on.

  16. Do not use the device in sunny places. When the device overheats, the overheat protection will switch on the device.

  17. To ensure effective cooling, a distance of at least 60 cm should be kept between the sidewalls of the device and the wall or furniture, or curtains.

  18.  Due to the limited performance of the device, if the difference between the target temperature and the ambient temperature is too great, the target temperature may not
    be reached.

  19. To reduce the risk of fire, electric shock, or injury when using the air conditioner, observe the following basic precautions:
    a) Connect to a grounded outlet with 3 pins.
    b) Do not remove the grounding prong.
    c) Do not use the adapter.
    d) Do not use an extension cord.
    e) Disconnect the air conditioner before servicing.
    f) Use two or more people to move and install the air conditioner.

  20.  Do not use agents accelerating the defrosting or cleaning process other than those recommended by the manufacturer.

  21. The device should be stored in a room without constantly operating sources of ignition, for example, open fire, gas appliances, or electric heaters.

BEFORE FIRST USE – (picture E)

Connect the connectors to the air exhaust duct as follows:

  1.  Extend the air exhaust duct (10) by drawing out the two ends of the duct.
  2. Screw the air exhaust duct (10) into the connector of the air exhaust duct (11).
  3. Connect the connector of the air exhaust duct (11) to the device.

REMARKS:

  1. Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference.
  2. Do not expose the unit under direct sunlight to avoid surface color fading.
  3. Do not tilt the unit for more than 35°or upside-down while transporting. If the device has been turned over during transport, put it down correctly and wait 2-4 hours before starting it.
  4. Place the unit on a flat surface with less than 5°inclination.
  5. The unit operates more efficiently in certain room locations, select the best location:
    – Beside a window, a door, or a French window.
    – Keep the required distance from the return air outlet to the wall or other obstacles at least 60 cm.
    – Extend the air hose to ensure that another end of the air hose has a clearance between the window door, or French window, or wall hole.
    – Air outlet or intake cannot be blocked by a protective grid or any obstacle. To extend the life of the unit, drain the condensed water from the upper (8) and lower (9) cooler drain holes before putting the unit into storage at the end of the season.
    DEVICE DESCRIPTION (pictures A and B)

| 7. Evaporator inlet
---|---
2. Cold air outlet| 8. Drain plug
3. Signal receptor| 9. Front room temperature display
4. Remote controller| 10. Air exhaust duct
---|---
5. Transport handle| 11. Connector of the air exhaust duct
6. Exhaust duct| 12. Window exhaust adapter

CONTROL PANEL (picture C)

A. Power button ON/OFF B. Fan speed button
C. Mode button D. Timer / Temperature up button
E. Timer / Temperature down button F. Low-speed lamp
G. High-speed lamp I. Sleep mode / Child lock button
J. Automatic mode lamp K. Cool mode lamp
L. Dry mode lamp M. Fan mode lamp
N. Timer button O. Oscillation button
P. Top room temperature display R. Power lamp

REMOTE CONTROLLER – picture D
The remote controller transmits signals to the system.
Button “A” – the appliance will be started when it is energized or will be stopped when it is in operation if you press this button.
Button “C” – press it to select operation mode: “J”, “K”, “L” or “M”.
Button “B” – press it to select fan speed in sequence.
Button “D” / “E” – press to adjust the room temperature and the timer.
Button “I” – press to set or cancel sleep mode. The child lock function is not available via remote control.
Button “N” – press to set the time of automatic off and automatic on.
Button “O” – press to set or cancel louvers swing mode.

OPERATION OF THE CONTROL PANEL

AUTOMATIC / COOL / DRY / FAN

  1. Turn on the device.
    a) Connect the device.
    b) Press the “A” button, then the device beeps once and turns on.
    c) LED displays (9 and P) show the room temperature and start working in automatic mode.

  2. Choose the operating mode Press the “C” button to select the desired mode of operation by sequence: Automatic mode “J” -> Cooling mode “K” -> Drying mode “L” -> Fan mode “M”

  3. Adjust temperature The temperature can be set within a range of 15°-31°C. Press the “D” or “E” button to increase or decrease the temperature by 1°C by pressing once. The device LED panel shows the target temperature for 5 seconds and then displays the room temperature.

  4. Adjust fan speed Press the button “B” to select the desired fan speed shown by sequence: Low speed “F” -> High-speed G

  5. Power When you press the “A” button again, the device will sound “di” and stop working.

  6. Press this button “I” to enter the sleep mode of the device or keep the button for a few seconds to switch on the child lock function.

  7. Press this button “N” to set a timed shutdown.

  8. Press this button “ O” to set air swing oscillation in the left and right directions.
    Each mode working principle:
    AUTO “J” mode: Once the “J” mode operation is selected, the indoor temperature sensor operates automatically and it selects one of the below operation
    modes:

  • When the room temperature is≥24°C the unit will automatically select the cool mode “K” mode.
    or
    *When the room temperature is 24< °C, the unit will automatically select high fan speed mode “M..”. Once, the auto mode “J” operation is selected, the indoor temperature  sensor operates automatically, it selects operation mode between fan “M” mode or “K” cool mode to keep desired room temperature.

Dry “L” mode (room air dehumidification):

  1.  The up centrifugal fan will run at low speed, and the speed can’t be adjusted.
  2.  The compressor will stop after running 8 minutes, then run again after 6 minutes.
  3. The device adopts a constant temperature dehumidifying mode, and the adjustment of temperature is not effective.
    WARNING:
    When operating the device in conditions of varying humidity, the drain plug (8) should be constantly open and ensure constant water drainage. You can mount the pipe included in the kit to pour water into an external tank or drain.

COOL “K” mode:

  1.  When the room temperature is higher than the set temperature on the control panel, the compressor starts to run.
  2.  When the room temperature is lower than the set temperature on the control panel, the compressor stops, and the upper fan operates at an original set speed.

Fan “M” mode.

  1. The up centrifugal fan runs at a set speed, and the compressor does not run. .
  2. The adjustment of temperature is not effective.

Timer operation “N”:

  1.  Press the “N” button to set Automatic Off time while the unit is running.
  2.  Press the “N” button to set Automatic On-time while the unit is ready.
  3. The time can be adjusted within a range of 1 hour to 24 hours by pressing the button “D” + or “E” –

.Sleep mode “I” operation:

  1.  The sleep mode operations when the unit is undercooling “K” mode.
  2. Press the button “I” in cool model “K”, then the unit will work under sleep mode and the up centrifugal fan will turn to low speed automatically. The set temperature will increase by 1 after one hour, and increase by 2 after two hours. After six hours the unit will
    stop running.
    Press the button “I” continuously for a few seconds to switch on the child lock function, then all buttons on the control panel will be deactivated. To switch off the child lock function press the button “I” for a few seconds again.
    Swing “O” mode operation:
    When the device is on, press the button “O”, the louver will be on or off. When it is on, the louver can swing left and right sides within 60 degrees. Press the button “O” again, the louver will stop swinging.
    Notice:
    The main control board has a memory function, when the device is ready to run but in stop status, the main control board can memorize the initialization of working mode. When you turn on the unit, it will work as the same enactment of working mode as last time, no need to reset the working mode again. (This condition is not available when the unit is under AUTO mode “J”.)

REMOTE CONTROLLER

  1. Slide the back cover to open and take off the isolating film on the batteries.
  2.  Put the batteries inside the slot, which must be corresponding to the signs of “+” and “-” on the remote control.
  3. For a long time no use, take out the batteries.
  4. To prevent environmental pollution, take out the used batteries and dispose of them safely and appropriately. To operate the device, aim the remote controller at the signal receptor. The remote controller will operate the device at a distance of 5  meters when pointing at the signal receptor of the device.

PROTECTIVE DEVICES

The protective device may trip and stop the appliance in the cases listed below:

  1.  at cooling mode: indoor air temperature is over 43°C (109°F)
  2.  at cooling mode: room temperature is below 15°C (59°F)
  3. at dehumidifying mode: room temperature is below 15°C (59°F). If the device runs in cooling “K” or dry “L” mode with door or window opened for a long time when relative humidity is above 80%, dew may drip down from the outlet.
    The protective device will work in the following cases:

1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF – must be set again.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain the water completely. After the drain, re-install the plug, or the appliance may leak and make your room wet.
If the appliance is placed in a position admitting drain water, you also can connect the drain hole to the drain port to drain the water.
The drainpipe is added to the kit, it is inner diameter 9mm, outer diameter 12mm, material: PVC.

Troubleshooting

  1.  Trouble: Do not work.
    Analysis:
    a) maybe the protector trip or fuse is blown, please wait for 3 minutes and start again, the protector device may be preventing the device from working.
    c) maybe batteries in the remote controller are exhausted.
    d) maybe the plug is not properly plugged in.

  2.  Trouble: works for a short time only
    Analysis:
    a) if the set temperature is close to room temperature, you can lower the set temperature.
    b) may be air outlet is blocked by obstacles. Take the obstacle away.

  3. Trouble: Works but not cools
    Analysis:
    a) maybe the door or window is open.
    b) may be in the close distance there is another appliance heat-working like heater or lamp, etc.
    c) the air filter is dirty, please clean it.
    d) air outlet or intake is blocked.
    e) set temperature is too high.

  4. Trouble: Water leak during moving.
    Analysis:
    a) drain the condensate before moving.
    b) to avoid water leakage, please locate the device on flat ground.

  5. Trouble: Do not work and water full indicator “E4”
    Analysis:
    a) pull out a rubber plug to drain water.
    b) if it is often in this state, please contact a qualified service technician.

  6. Trouble: The device fails to start up.
    Analysis:
    a) maybe not plugged. So, plugin it.
    b) maybe plug or socket damages. Replace by service provider.
    c) may be fuse broken. Replace the fuse with the service provider (specification: 3,15A/250VAC).

  7. Trouble: The device automatically stops.
    Analysis:
    a) timing shut down or set temperature reached. Restart it or wait for auto- switch.

  8. Trouble: no cold air under COOL “K” mode.
    Analysis:
    a) room temperature is lower than the set temperature. It is a normal phenomenon, the machine will auto-switch while the room temperature is higher than the set temperature.
    b) Device enters into anti-frost protection. The device will auto switch after anti-frost protection is over.

  9. Trouble: LED displays failure code “E2”
    Analysis:
    a) room temperature sensor fails or damages. Replace the room temperature sensor with the service provider.

  10. Trouble: LED displays failure code “E3”
    Analysis:
    a) the evaporator oil pipe sensor fails or is damaged. Replace the evaporator coil pipe sensor by the service provider.

  11. Trouble: LED displays failure code “E4”
    Analysis:
    a) water-full warning. Drain out the water. CLEANING AND MAINTENANCE

Device maintenance

  1.  Turn off the device first before disconnecting from the power supply.
  2. Wipe with a soft and dry cloth. Use lukewarm water below 40°C to clean if the appliance is very dirty.
  3. Never use volatile substances such as gasoline or polishing powder to clean the device.

Air filter maintenance It is necessary to clean the air filter every 2 weeks if the device operates in an extremely dusty environment. Clean as follows:

  1.  Stop the device first, push up the air filter (Picture F).
  2. Clean and reinstall the air filter.
  3. If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After cleaning dry it in a shaded and cool place, then reinstall it.

Maintenance after using

  1. If the device will not use for a longer time, be sure to pull out the rubber drain plug (8) of the drain hole in order to drain the water.
  2. Keep the appliance running with a fan only for a half-day during a sunny day to dry the appliance inside and prevent it from going moldy.
  3.  Stop the device and pull out the power cord plug, then take out the batteries of the remote controller and store the device properly.
  4.  Clean the air filter and reinstall it.
  5. Remove the air hoses and store them properly, and cover the hole tightly.

TECHNICAL DATA:

Cooling capacity at BTU: 7000 BTU / hour Cooling capacity in watts: 2000
Energy consumption (cooling) W: 750 W Volume: <= 65dB
Airflow: 250 m3 / h Energy class: A
Timer: 24 hours R290 coolant weight: max. 135 grams

Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odor.
The maximum refrigerant charge amount: 135g.

To protect your environment: please separate carton boxes and plastic bags and dispose of them in corresponding waste bins. Used appliances should be delivered to the dedicated collecting points due to hazardous components, which may affect the environment. Do not dispose of this appliance in the common waste bin.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals