CONTROLS

SELECTING UNITS OF MEASURE

  1. Pressthe the @ (Units) key to toggle the Units of measure indicator untl the des red unitof measure is displayed.
  2. Five different unit selectionsare avalabl: kg-cm, k-gm, in-b, 1, and N

SETTING PRESET VALUES

SELECTING MEMORY PRESETS

Select 1 of 10 user programable memory presets

CHANGING OR IENTATION OF DISPLAY

Press and hold(® button for 2 seconds to toggle the orientation of the display readout.

SELECTING PEAK HOLD/TRACKING MODES

In Track mode – The display wil regis ter ‘real-time” torque s it is applied. This is us eful when you are able: to observe the digital display while applying torque to a fas tener. Watching the torque valincrease can as sis tyou in applying torque evenly and safely, especially as you approach your targ torque setting.

PEAK HOLD MODE OPERATION

In Peak hold mode, the digital display shows the maximum torque applied, which can be helpful for verifying that the correct torque was applied when the digital display is not visible during use. This mode  is also handy when using the adapter to calibrate a torque wrench.

TRACKING MODE OPERATION

the digital display while applying torque to a fas tener. Watching the torque value increase can as s s t You in applying torque evenly and safely, especially as you approach your target torque setting.

Tracking Mode

Select TP pre-setting: 200 kg-cm

  • Percentage of preset torque value s displayed

**At 70% of target torque:

**

  • Percentage of preset torque value s displayed
  • *Buzzersounds
  • Red LE D flashes

**At 90% of target torque:

**

  • Percentage of preset torque value s displayed
  • Buzzer sounds : B1-81 8181
  • Red LED flashes

**AL100% of target torque:

**

  • Percentage of preset torque value is displayed
  • Buzzer sounds
  • Red LED flashes
  • Vibration alert activates.

POWERING OFF DIGITAL TORQUE ADAPTER

Press and hold Mode button for 2 seconds to turn unit off.
NOTE : This tool will automatically enter s leep mode after 3 minutes of inactivity.

  1. Use a screwdriver to open the rear case .

  2. Replace CR2032 Type battery .

CALIBRATING A TORQUE WRENCH USING DIGITAL ADAPTER

  1. Set your torque wrench to a value of approximately 25% of its maximunm capacity. For example, if your torque wrench has a maximum capacity of 150 b-f,set t to 40 bt
  2. Program the digital torque adapter for a torque value that matches the torque wrench setting. In our example, you would set the ‘adapter for 40 b-ft. E nsure the adapter i in the “peak” mode as this wil make it easy to reference actual torque versus the torque. indicated on the wrench.
  3. Connect the pre-set torque wrench and the calibration adapter (not included) to the digital torque adapter. Secure the calibration ‘adapterin a bench vise. Ensure the calibration ‘adapter i securely tightened in the vise.
  4. Turn the torque wrench smoothly and steadily, applying torque to the calibration ‘adapter until your torque wrench reaches the preset value, either by “clicking’ (micrometers tyle torque wrench),or displaying the desired settingligitalor dial torque wrench).
  5. Read the peak torque value shown on the digital torque adapter. Adjust your torque ‘wrench and repeat the procedure until the torque wrench and digital torque adapter show dentica torque values