Arrowhead Alarm AJ-765 Smoke and Heat Detectors Instruction Manual
- June 12, 2024
- Arrowhead Alarm
Table of Contents
AJ-765
Auto Resetting Smoke Detector
with Wireless Interconnect
Specifications
Detection Type: | Photoelectric Chamber |
---|---|
Power Source: | Battery up to 10 year life |
Buzzer Output: | 85db @ 3 meters |
Wireless Frequency: | 433MHz |
Interconnect Range | up to 50 meters apart |
Dimensions: | 40mm x Ø110mm |
Operating Temp. Range: | : 0˚C to 40˚C |
Compatible with: | AJ-718 Heat Detector |
AJ-R106 Remote Test & Hush Controller
Standards:| EN14604:2005/AC:2008
& AS3786:2014
Operation & Testing
Routine Testing of smoke detectors should be done once a month.
To test the AJ-765 smoke detectors press the test button for less than 1
second. The sounder should activate. Any other linked detectors should also
activate within 20 seconds.
The smoke detectors sounder will automatically reset, when all the smoke has
cleared.
Hush feature. When the smoke detector has been activated, pressing the
test button for less than 1 second will silence that smoke detectors sounde
Indication:
Green Flash every 60 seconds, Detector is performing correctly Red Flash every
8 seconds plus beep, Faulty, Clean/Replacement required
Red Flash every 50 seconds plus beep, Battery Low, Replacement require Red
Flashing with No beeping, in Hush mode for 9 minutes
*When using any aerosol smoke detector tester, please follow all instructions provided on the can. Improper use may result in degraded detector performance.
**Routine cleaning is required to ensure no false triggers.
Mounting Clearances
*Always refer to latest standards/building code for mounting locations
Pairing AJ-765 Smoke Detectors with Wireless Interconnect
Step 1.
Power On
Flick the switch on the bottom of each detector to the On position.
Note. Locking detectors to their base automatically turns them On.
Note. AJ-765 smoke detectors can also be paired with AJ-718 heat
detectors and AJ-R106 remote.
Step 2.
Clear Memory
Press & hold the test button until the Green light has flashed 4 times.
The Green light will then flash back 3 times slowly.
This must be done on all detectors before Pairing.
Step 3.
Select a Master
Press & hold the test button of the detector to be the master, until the Green
light has flashed 3 times.
The Red light will then start flashing to indicate its in Pairing mode.
(60 seconds maximum)
Step 4.
Learn in a detector
Press & hold the test button of a slave detector, until the Green light has
flashed 2 times.
The Red light will then start flashing as it tries to learn
The Green light will flash 3 times to indicate it has paired.
Repeat Step 4, on all other detectors until they have been paired. Step 5.
Wait 60 second before testing
Step 6.
Testing
Press the test button (for less than 1 second) on one of the detectors.
Within 20 seconds all detectors paired together should also activate.
Note. The hush button can be pressed on each detector, without affecting the
wireless interlink test.