SALUS GGPC1 Main Switch
Product Information
Mains Switch Model GGPC1
The Mains Switch Model GGPC1 is an RF solution that allows for the switching ON or OFF of a Heating Ventilation and Air Conditioning (HVAC) pump under direct control from the boiler. The product is designed and manufactured by SALUS Controls, a member of the Computime Group, with headquarters located at Units 8-10, Northfield Business Park, Forge Way, Parkgate Rotherham, S60 1SD. SALUS Controls is committed to continuous product development and as such, reserves the right to change the specification, design, and materials of products listed in this brochure without prior notice. The product is compliant with Directives RED 2014/53/EU and RoHS 2011/65/EU.
Product Compliance
The Mains Switch Model GGPC1 complies with the essential requirements and other relevant provisions of Directives RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
It is important to use the product in accordance with regulations and for indoor use only. Keep the device completely dry and disconnect it before cleaning it with a dry cloth. The Mains Switch must be fitted by a competent person and installation must comply with the guidance, standards, and regulations applicable to the city, country, or state where the product is installed. Failure to comply with relevant standards could lead to prosecution.
Utility
The Mains Switch Model GGPC1 eliminates the need for cabling when switching ON or OFF an HVAC pump located away from the boiler. The relay can also be used in other similar applications with other devices.
RF Communication
The product uses RF communication at 868.0-868.6MHz.
Product Usage Instructions
Before using the Mains Switch Model GGPC1, ensure that the device is installed by a competent person and in compliance with the guidance, standards, and regulations applicable to the city, country, or state where the product is installed. Follow these usage instructions:
- Locate the Boiler Transmitter and Pump Receiver assemblies.
- Connect the Boiler Transmitter assembly to the boiler by connecting the L and N terminals.
- Connect the Pump Receiver assembly to the pump by connecting the SL, N, and L terminals.
- Ensure that the Boiler Transmitter and Pump Receiver assemblies are within range of the radio signal for pump control.
- To switch ON or OFF the HVAC pump, use the Mains Switch Model GGPC1.
Remember to use the product in accordance with regulations and for indoor use only. Keep the device completely dry and disconnect it before cleaning it with a dry cloth.
assembly
WIRING
Introduction
The mains Switch is an RF solution to switch ON or OFF a Heating Ventilation
and Air Conditioning (HVAC) pump under direct control from the boiler.
Product Compliance
This product complies with the essential requirements and other relevant
provisions of Directives RED 2014/53/EU and RoHS 2011/65/EU. The full text of
the EU Declaration of Conformity is available at the following internet
address: www.saluslegal.com
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Utility
The pump is not normally located close to the boiler, in which case a mains
cable must be run from the boiler to the pump. Using Mains Switch eradicates
the need for cabling.
The relay can be used in other similar applications (with other devices).
RF Communication
868.0-868.6MHz; <13dBm
Range:
- approximately 100 meters in open space
- typical indoor range : 35 meters (depends on the indoor structure)
Pairing code
- The Boiler Transmitter and the Pump Receiver will share one unique factory pre-matched 3-byte pairing code. The number of combinations (16,777,216) ensures no adjoining units should share the same pairing code.
Components
Mains Switch consists of two units:
- The Boiler Transmitter
- The Pump Receiver
Also included are two mounting brackets for each unit.
The Boiler Transmitter
The Boiler Transmitter is connected to the boiler which both powers the unit and detects the presence of the 230VAC pump signal output from the boiler.
Terminals
Please wire the Boiler Transmitter in accordance with the wiring diagram
below:
L | Live |
---|---|
N | Neutral |
Temporary power backup:
The Boiler Transmitter uses a super capacitor to backup power in order to
transmit an OFF command twice at 5 second intervals, when it detects the
boiler output off.
Device Function
Normal Mode
The Boiler Transmitter keeps detecting the 230VAC input.
When 230VAC is detected, an RF ON signal is transmitted to the RF Pump
Receiver and repeated every 5 seconds.
When power is removed from the Boiler Transmitter, a temporary power backup
(Super Capacitor) will be used to transmit an OFF command twice at 5 second
intervals.
Pairing Mode
The Boiler Transmitter keeps broadcasting pairing code every 5 seconds until
60 second timeout.
Button Operation & LED Indicator
Button operation | LED State | Description |
---|
Press the button
3 times
within 1 second
| Orange Flash| When the user presses the transmitter button 3 times within 1
second, the transmitter will send the pairing information at 5 second
intervals for one minute. The transmitter LED will flash orange (red/ green
ON) at 0.5Hz for one minute.
N/A| Green On| The LED will be lit green when the unit is powered.
N/A| Red On| The LED will be lit red for 1 minute when the unit is powered
off.
The Pump Receiver
The Pump Receiver keeps listening for the RF ON/OFF signal. The pump will be switched ON when an RF ON signal is received. The Pump Receiver will switch off the pump upon receiving an OFF command or if an ON command is not received within 21 seconds.
Terminals
Please wire the Pump Receiver in accordance with the wiring diagram below:
SL | Switch Live-out |
---|---|
N | Neutral out |
N | Neutral input |
L | Live Input |
E | Earth |
E | Earth |
Device Function
Normal Mode
The Pump Receiver keeps listening for the RF ON/OFF signal. The Pump will be
switched ON when an RF ON signal is received.
Once switched ON the Pump Receiver will switch OFF the pump upon receipt of an
OFF command or if an ON command is not received within 21 seconds (RF Watch
Dog).
Pairing Mode
The Pump Receiver keeps listening for the pairing code until the pairing code
is received or it will time out after 60 seconds.
The received pairing code will replace the pre-attached pairing code.
Button Operation & LED Indicator
Button operation | LED State | Description |
---|
Press the button
3 times
within 1 second
| Orange Flash| When the user presses the receiver button 3 times within 1
second, the LED of the receiver will flash orange (red/green ON) at 0.5Hz for
1 minute waiting for pairing information from the transmitter.
N/A| Green On| The LED will be lit green when the unit is powered and the pump
is switched ON.
N/A| Red On| The LED will be lit red when the unit is powered and the pump is
switched OFF.
- Head Office:
- SALUS Controls
- Units 8-10, Northfield Business Park,
- Forge Way, Parkgate
- Rotherham, $60 1SD
- Email:sales@salus-tech.com
- www.salus-controls.com
- SALUS Controls is a member of the Computime Group.
- Maintaining a policy of continuous product development SALUS Controls pc reserves the right to change the specification, design, and materials of products listed in this brochure without prior notice.
- Date: March 2022
- Version: VOO3
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>