Introduction

HTRP-RF(50) is a programmable wireless digital room thermostat compatible with devices that are part of the IT600 series, such as: KL08RF wiring center, TRV10RFM thermostatic radiator valve and RX10RF boiler receiver. If you want the thermostat to control the devices via Internet (Online Mode), please use the UGE600 universal gateway and connect it to the SALUS Smart Home app. You can also use the thermostat to control the devices locally without Internet connection (Offline Mode) but in this case the communication between devices must be done using the CO10RF coordinator.

Product Compliance

This product complies with EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity on www.saluslegal.com
2405-2480MHz; <14dBm

Safety Information

Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth.

Wiring diagram

Power supply:
2 x AA alkaline batteries
S1 & S2 terminals:- external temperature sensor (air or floor)
– external switch (occupancy sensor)
Mounting: surface mounting (after removing the back case)

LCD icons

  1. Comfort temperature
  2. Standard temperature
  3. Reduced temperature
  4. Auto mode
  5. Party mode
  6. Holiday mode
  7. Frost protection mode
  8. Heating Mode ON
  9. RF signal
  10. Internet connection
  11. Cooling Mode ON
  12. Manual Mode / Temporary Override
  13. Current Temperature
  14. Lock key
  15. AM / PM
  16. Day of the week
  17. Hour
  18. Settings
  19. Low battery
  20. Sensor connected
  21. Program number

Button functions

|

|
---|---|---
Mode selection.
Long press to return to main screen without saving. Short press to return to previous screen.| Decrease or increase Setpoint Temperature.
Decrease or increase Day, Clock.| OK key. Short press to confirm selection.
Long press to save and return to main screen.
Long press to enter Program/Clock/Offset.

Button combinations

+

|

+

---|---
Press and hold the buttons simultaneously to lock or unlock the keypad.| Press and hold the buttons simultaneously to enter installer mode.

Zigbee network coordinators

I. Online: connected to the Internet using the UG600 universal gateway.
II. Offline: with the possibility of connecting to the Internet using the UG600  universal gateway.
III. Offline: without any possibility of connecting to the Internet using the CO10RF coordinator.

Select the device that is going to be controlled by the thermostat and the type of Zigbee network coordinator you want to use. Install the devices according to the instructions attached to each product.

Power up

After inserting the batteries, the thermostat will display the software version and it will power up.

After the first power up, you can choose to pair the thermostat either with underfloor heating (UFH) or with radiators (read):

| KL08RF wiring center
---|---
| TRV10RFM thermostatic radiator valve

Extended configuration

Extended configuration should be used only if you want to pair the thermostat with the boiler receiver. To do so, press the buttons shown below simultaneously until all visible icons flash once.

Choose the device type according to the screens below:

| Underfloor heating
---|---
| RX10RF in RX1 mode
| Radiator heating
| RX10RF in RX2 mode

OFFLINE PAIRING PROCEDURE

The offline pairing method should be used by non-internet users only
WARNING! Do not use CO10RF coordinator with UG600 simultaneously

Pairing with the Wiring Centre

Select on the LCD.

Open the ZigBee network

Select the wiring center number using or (max 9). Confirm your choice by pressing

Select the group number (offline only) using or . Confirm your choice by pressing .

Select the zone number using or .Confirm your choice by pressing .

Close the ZigBee network

Pairing with the TRV

WARNING! You can connect up to 6 TRVs to one thermostat.

Press and hold the  button for 10 seconds. The LED will start flashing red.

Select on the LCD

Open the ZigBee network


Press to confirm the pairing with the TRV.

Press . The LED on the TRV will flash green one time and then it will turn off.

The LCD will display the number of paired devices. Press to finish.

Close the ZigBee network

Pairing with the boiler receiver

WARNING! In a ZigBee network, you can use only one RX10RF configured as RX1 and only one RX10RF configured as RX2.

In order to pair directly the thermostat with the boiler receiver, please follow the Extended configuration procedure.

Open the ZigBee network



Close the ZigBee network

ONLINE PAIRING PROCEDURE

Please use the online pairing method when you are using UG600 to configure your system. Follow the on-screen instructions to complete the setup

ONLINE

Please use the online pairing method when you are using UG600 to configure your system. Follow the on-screen instructions to complete the setup.

Go to the App




Once you have selected your device type, follow the onscreen instructions to complete the setup.

Identify paired devices

Go to Installer Mode, select parameter 00 and press .


The LEDs on the paired devices will start to flash.

Press to exit installer mode

Change temperature setpoint

If thermostat works in AUTO mode, then the overwritten temperature (temporary override) will be maintained until next program. In manual mode and frost protection mode temperature change is permanent.

Factory Reset