Introduction
HTRP-RF(50) is a programmable wireless digital room thermostat compatible with devices that are part of the IT600 series, such as: KL08RF wiring center, TRV10RFM thermostatic radiator valve and RX10RF boiler receiver. If you want the thermostat to control the devices via Internet (Online Mode), please use the UGE600 universal gateway and connect it to the SALUS Smart Home app. You can also use the thermostat to control the devices locally without Internet connection (Offline Mode) but in this case the communication between devices must be done using the CO10RF coordinator.
Product Compliance
This product complies with EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and
RoHS 2011/65/EU. Full text of the EU Declaration of Conformity on
www.saluslegal.com
2405-2480MHz; <14dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth.
Wiring diagram
Power supply:
2 x AA alkaline batteries
S1 & S2 terminals:- external temperature sensor (air or floor)
– external switch (occupancy sensor)
Mounting: surface mounting (after removing the back case)
LCD icons
- Comfort temperature
- Standard temperature
- Reduced temperature
- Auto mode
- Party mode
- Holiday mode
- Frost protection mode
- Heating Mode ON
- RF signal
- Internet connection
- Cooling Mode ON
- Manual Mode / Temporary Override
- Current Temperature
- Lock key
- AM / PM
- Day of the week
- Hour
- Settings
- Low battery
- Sensor connected
- Program number
Button functions
|
|
---|---|---
Mode selection.
Long press to return to main screen without saving. Short press to return to
previous screen.| Decrease or increase Setpoint Temperature.
Decrease or increase Day, Clock.| OK key. Short press to confirm selection.
Long press to save and return to main screen.
Long press to enter Program/Clock/Offset.
Button combinations
+
|
+
---|---
Press and hold the buttons simultaneously to lock or unlock the keypad.| Press
and hold the buttons simultaneously to enter installer mode.
Zigbee network coordinators
I. Online: connected to the Internet using the UG600 universal gateway.
II. Offline: with the possibility of connecting to the Internet using the
UG600 universal gateway.
III. Offline: without any possibility of connecting to the Internet using
the CO10RF coordinator.
Select the device that is going to be controlled by the thermostat and the
type of Zigbee network coordinator you want to use. Install the devices
according to the instructions attached to each product.
Power up
After inserting the batteries, the thermostat will display the software version and it will power up.
After the first power up, you can choose to pair the thermostat either with underfloor heating (UFH) or with radiators (read):
| KL08RF wiring center
---|---
| TRV10RFM thermostatic radiator valve
Extended configuration
Extended configuration should be used only if you want to pair the thermostat
with the boiler receiver. To do so, press the buttons shown below
simultaneously until all visible icons flash once.
Choose the device type according to the screens below:
| Underfloor heating
---|---
| RX10RF in RX1 mode
| Radiator heating
| RX10RF in RX2 mode
OFFLINE PAIRING PROCEDURE
The offline pairing method should be used by non-internet users only
WARNING! Do not use CO10RF coordinator with UG600 simultaneously
Pairing with the Wiring Centre
Select on the LCD.
Open the ZigBee network
Select the wiring center number using or (max 9). Confirm your choice by pressing
Select the group number (offline only) using or . Confirm your choice by pressing .
Select the zone number using or .Confirm your choice by pressing .
Close the ZigBee network
Pairing with the TRV
WARNING! You can connect up to 6 TRVs to one thermostat.
Press and hold the button for 10 seconds. The LED will start flashing red.
Select on the LCD
Open the ZigBee network
Press to confirm the pairing with the TRV.
Press . The LED on the TRV will flash green one time and then it will turn
off.
The LCD will display the number of paired devices. Press to finish.
Close the ZigBee network
Pairing with the boiler receiver
WARNING! In a ZigBee network, you can use only one RX10RF configured as
RX1 and only one RX10RF configured as RX2.
In order to pair directly the thermostat with the boiler receiver, please
follow the Extended configuration procedure.
Open the ZigBee network
Close the ZigBee network
ONLINE PAIRING PROCEDURE
Please use the online pairing method when you are using UG600 to configure
your system. Follow the on-screen instructions to complete the setup
ONLINE
Please use the online pairing method when you are using UG600 to configure your system. Follow the on-screen instructions to complete the setup.
Go to the App
Once you have selected your device type, follow the onscreen instructions to complete the setup.
Identify paired devices
Go to Installer Mode, select parameter 00 and press .
The LEDs on the paired devices will start to flash.
Press to exit installer mode
Change temperature setpoint
If thermostat works in AUTO mode, then the overwritten temperature (temporary
override) will be maintained until next program. In manual mode and frost
protection mode temperature change is permanent.
Factory Reset
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>