intelbras IVP 3011 Teto Passive Infrared Sensor for Ceilings User Manual
- July 8, 2024
- intelbras
Table of Contents
intelbras IVP 3011 Teto Passive Infrared Sensor for Ceilings
Specifications
- Operating voltage: 12V
- Operating current: 500 mA
- Operating temperature: NF – NA (100 Vdc)
- Detection method: PIR
- Detection distance: Diameter 7m
- Alarm outlet: NF – NA (500 mA 100 Vdc)
- Recommended installation height: 3 meters
- Startup time: 44mm
- Detection angle: 66°
- Anti-tamper key (TAMPER): Yes
- Size: 1100mm x 32mm x 32mm
- LED: Yes
- Detection pulse (P. COUNT): 1-3 pulses
Product Usage Instructions
1. Installation
To attach the sensor in the ceiling, follow these steps:
- Open the front cover pulling it upward.
- Pass the cable through the cable passage orifice in the back cover.
- Connect the cable to the terminal block.
- Attach the sensor in the ceiling using the provided screws.
2. Operation
To operate the sensor:
- Switch on the LED to activate the sensor.
- Adjust the sensitivity and coverage area based on the installation position.
3. Testing
To test the sensor:
- Energize the sensor to activate the self-test.
- Observe the LED indication during a walk-through test.
- Check if the desired area is within the sensor’s coverage.
FAQ
- Q: What should I do if the LED does not light up during testing?
- A: Check the power connection and ensure that the sensor is properly installed and configured.
- Q: Can I adjust the detection range of the sensor?
- A: The detection range may be influenced by environmental factors; however, you can adjust the sensitivity and coverage area during installation.
- Q: Is professional installation required for this product?
- A: It is recommended to follow the installation instructions provided in the manual. If unsure, seek assistance from a skilled technician for proper installation.
IVP 3011 Teto (Ceiling) Infrared passive sensor
Congratulations, you just have purchased a product with Intelbras quality and safety. IVP 3011 Teto sensor has a 360° view angle and its detection is done by passive infrared rays, reducing the risk of false shots.
Caution and safety
- LGPD – General Law for the Protection of Personal Data: Intelbras does not access, transfer, capture, or perform any other type of treatment of personal data from this product.
- Follow all instructions of the manual for product mounting and installation.
- This movement sensor is to be used in indoor environments.
- Do not touch on surface of the infrared sensor (PIR). If necessary, use a soft cloth with alcohol to clean.
- The sensor must be installed where a possible intruder could be easily detected, that is, where a person does transversal movements in relation to the sensor detection beams when entering into the environment. The suggested installation height is 4 m.
- Do not put objects in front of the sensor that may block scanning.
- Avoid installing the sensor near to the following interference sources: reflexive surface, areas subject to sudden temperature changes (such as air conditioners and heaters, fans, refrigerators and ovens).
- Avoid installing in places where sunlight goes directly onto the sensor.
- Install the sensor in a stable and shake-free place.
- For your safety, perform test of product and systems at least once a week. It is necessary due to changes in environmental conditions, electronic failures or power outage and flaws. Take all the required precautions to keep your property safe and protected.
Top view scan
Detection range (side view)
Terminal block
- Tamper: Anti-tamper key
- (-) GND: negative source
- (+) 12 V: Positive source
- Alarm: sensor output
Technical specifications
Note: the infrared detection range can be influenced by the environment.
Features
- Ceiling installation.
- Digital signal processing (DSP).
- Automatic temperature compensation.
- Anti-tamper protection (tamper key).
- Adjustable infrared sensitiveness (PIR).
- Optional NF and NA relay output.
Producto
- Front
- Lens
- Base
- Bolt fixation holes
- Cable passage
- Jumper P.COUNT (pulse counter)
- Jumper Relay
- PIR sensor
- Jumper LED
- LED Indicator
- Terminal Block (connectors)
- Tamper key (anti-violation)
Installation
- Execute the installation in an area free of obstacles that may hinder the visual field of the sensor.
- The PIR (P-COUNT) sensitivity adjustment must be done according to each environment.
To attach the sensor in the ceiling, follow the procedure:
- Open the front cover pulling it upward (figures 1A and 1B);
- Pass the cable through the cable passage orifice in the back cover (Fig. 2);
- Pass the cable through the orifice and connect it to the terminal block (item 1.3. Terminal block);
- Attach the sensor in the ceiling, passing the screw through the holes in the back cover (Fig. 3).
Note: drilling screw M3 × 25.
Operation
LED jumper is used for LED indication without interfering with the detector. Jumper in ON position (pin 1 & 2) light on. Jumper in OFF position (pin 2 & 3) light off. Factory standard: LED on. The P.COUNT jumper controls the pulse count for alarm activation. With the jumper in the 1P position, the sensor provides maximum sensitivity (one pulse, pins 1 & 2) With the jumper in the 2P position, the sensor provides intermediary sensitiveness (two pulses, pins 2 & 3), and in this position, the sensor provides proper detection for environments with high incidence of EMI and RFI interferences. Factory standard: 2P.
Note: if the P.Count jumper is open, the sensor sensitivity will be 2P. The RELAY jumper controls the relay contact status. With jumper in the NF position, the contact is normally closed. With jumper in the NA position, the contact is normally open. Factory standard: NF.
Test
- When energized, the LED lights on, indicating that the self-test has been activated by the sensor.
- It performs the walk-through test, with transversal movements to sensor detection, by observing the LED indication.
- Note: while a movement could be detected, the LED remains on and will indicate open or closed.
- Walk through the area where you want to protect to check if it is within the area covered by the sensor. The sensor sensitivity and its installation position will define the coverage area.
Term of Warranty
It is expressed that this contractual warranty is granted according to the following conditions:
- Customer name:
- Customer’s signature:
- Tax Invoice No.
- Date of Purchase:
- Model: Serial No.:
- Retailer
- All parts, pieces and components of this product are warranted against any manufacturing defects, which may arise within a period of 1 (one) year – being 90 (ninety) days of legal warranty and 9 (nine) months subject to contractual warranty – from the date when the Customer purchased the product, according to the product purchase tax invoice, which is an integral part of this Term throughout the Brazilian territory. This contractual warranty expressly includes the product exchanges in case of manufacturing defect. If no manufacturing defect is confirmed, but there is a failure due to improper use, the Customer shall bear any of these incurred expenses.
- The product must be installed according to the Product Manual and/or Installation Guide. If your product requires to be installed and configured by a skilled technician, your should seek for a reliable and skilled professional, but the costs of such services are not included in the product price.
- Once the defect is confirmed, the Customer shall contact immediately the nearest Authorized Service listed in the report provided by the manufacturer, they are the only professionals authorized to check and remedy the defect within the warranty term provided herein. It it is not observed, the warranty is void, characterized as product infringement.
- Eventually, if the Customer requests service at home, he/she may contact the nearest Authorized Service to ask for fee quotation of a technical visit. If it is necessary to withdraw the product to be repaired, the incurred expenses such as transportation and insurance costs, including taking and return after repair, are under the responsibility of the customer.
- The warranty will be entirely voided if any of the following cases occur: a) if the defect is not due to manufacturing, but caused by the Customer or by third parties foreign to the manufacturer; b) if the product damages are caused by accident, disasters, agents of nature (lightning, flooding, landslide, etc.), humidity, network voltage, over-voltage caused by accident or excessive network voltage fluctuations), installation/use in disagreement with the user’s manual or due to natural wear of parts, pieces and components; c) if the product had suffered any effects of chemical, electromagnetic, electric or animal (insects, etc.) nature; d) if the product serial number was altered or erased; and e) if the appliance is flawed.
- This warranty does not cover data loss, therefore, in case of a product, it is advisable to the Customer to regularly make secure backup of the product data.
- Intelbras is not liable for the installation of this product, as well as eventual attempts of fraud and/or sabotage in their products. Keep software and applications up to date, and if necessary, the required network protections against intrusions (hackers). The equipment is warranted against defects under normal conditions of use, and it is important to bear in mind that, because it is electronic equipment, it is not protected from attempts of frauds or misleading actions that may interfere in its correct operation,
- Properly dispose of your product after its useful life – deliver it to collection points for electrical and electronic products, at an authorized Intelbras technical assistance center or consult our website www.intelbras.com.br and support@intelbras.com.br or (48) 2106-0006 or 0800 7042767 for more information.
Also under this supplementary Term of Warranty, Intelbras S/A reserves the right to alter general, technical or aesthetic features without prior notice. All images in this manual are for illustrative purposes only.
Contact
- Customer Support: (48) 2106 0006
- Forum: forum.intelbras.com.br
- Support via chat: chat.apps.intelbras.com.br
- Support via e-mail: suporte@intelbras.com.br
- Customer Service / Where to buy? / Who installs it?: 0800 7042767
- Imported to Brazil by: Intelbras S/A – Indústria de Telecomunicação Eletrônica Brasileira
- Rodovia SC 281, km 4,5 – Sertão do Maruim – São José/SC – 88122-001
- CNPJ 82.901.000/0014-41 –
- www.intelbras.com.br
- www.intelbras.com/en
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>