104522MS Steam Sauna Bath

104522MS Rough-in Package

103867 Condensation Pan n/a 11-21
MS81500E AutoFlush PUR100200E 06-21
104117-30 Control Cable n/a 11-21

OPTIONAL CONDENSATION PAN

MrSteam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak.
Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level (see page 5 for locating the steam generator).
All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Check local plumbing code for receptor, trap and vent requirements.
Condensation pans drain by gravity.
The condensation pan is equipped with an integral female ¾” NPT fitting.
Do not plumb the generator drain and condensation pan drain together in such a way that will cause drain water to back into condensation pan. BOX CONTENTS:

  • AutoFlush System Valve with Cord
  • Installation Instructions.

ASSEMBLY OF OPTIONAL AUTOFLUSH® SYSTEM

MrSteam 104522MS Steam Sauna Bath - ASSEMBLY OF OPTIONAL AUTOFLUSH
SYSTEM OPERATION
The optional AutoFlush System feature automatically drains the MrSteam system following each use. A time delay allows the water to cool down (about two hours) before it drains resulting in a safe and gentle operation.

INSTALLATION INSTRUCTIONS

  1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable National and Local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded ½” NPT. Check plumbing code for receptor, trap and vent requirements.

  2. Use copper or brass nipple ½” NPT x 3½” (90mm) or longer (not supplied) to connect AutoFlush valve (end “B”) to the Drain Valve (valve end “A” and “B” are indicated on bottom of AutoFlush Valve)
    CAUTION DO NOT REMOVE THE DRAIN VALVE
    Removal may cause equipment and property damage. If there is not enough room for the valve, an elbow and a short nipple (not provided) can be added.

  3. Open Drain Valve (handle must be aligned with brass nipple).

  4. Connect the AutoFlush System cord connector to the three pin connector as shown.

WARNING Do not drain into a steam enclosure or any location where accidental contact with drain water may occur. In the event of a power failure the AutoFlush System valve will open and may discharge boiling water.
SWEAT FITTINGS
When using sweat fittings use only tin base solder with a melting point below 600 degrees F. Do not overheat. Ends of water supply tubing must be thoroughly clean for a minimum distance of 1″ from ends. Do not remove valve cover.
TO CHECK OPERATION

  1. Turn on MrSteam with the control and allow tank to fill with water. (see MrSteam Instruction Manual)
  2. Turn off MrSteam with the control. Water should stay in tank.
  3. Turn off power at the panel box. Water should discharge from tank.
  4. Turn on power at panel box.
  5. Repeat

CAUTION PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
IMPORTANT NOTE: Contact the MrSteam Technical Service Dept.
for installation of any equipment not shown in these instructions.
East Coast: 800-767-8326; West Coast: 800-727-8326
AutoFlush® Shown Fully Assembled Installing AutoFlush on Older Model Generators SN:899,999 and below

  1. Remove the connector from the “C” location in the jacket. Cut off the connector where shown and strip back the wires approx 0.375″
  2. Cut the connector off the AutoFlush cable where shown and strip back the wires approx 0.375″.
  3. Remove the knockout in the side of the generator and install a bushing to prevent chafing.
  4. Route the wires from the AutoFlush through the knockouts and connect the white wire from the AutoFlush to the white wire from the circuit board using a wire nut. Repeat for the black wire.

WARRANTY: To view or download the MrSteam Controls & Accessories Warranty and register your product go to: blog.mrsteam.com/wr

LOCATING THE STEAM GENERATOR

Select a location as near as practical to the steam room.
Typical locations include: closet, vanity cabinet, heated attic or basement.
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and control must be located accordingly. A 60 foot cable is available as a special order part for iTempo® and AirTempo®, PN 103990-60 and PN 104117-60 for iSteam®. The maximum cable length is 60 feet.
IMPORTANT NOTE: The control cable should be run in a dedicated 1″ conduit to facilitate installation and service.
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
(Items 1-4)

  1. DO NOT install steambath generator inside steam room, a shock hazard will occur

  2. DO NOT install steambath generator outdoors or wherever environmental conditions may result in a shock hazard or affect performance of the generator.

  3. To prevent damage to the steam generator or a fire hazard DO NOT install steambath generator near flammable or corrosive materials or chemicals such as gasoline, paint thinners, or the like. Installation in areas having high concentrations of chlorine (such as pool equipment room) must be avoided.

  4. Burn Hazard. Steam piping, safety valve, drain valve and plumbing become hot during operation and remain hot after shutdown for a period of time. Provide appropriate protection, including insulating plumbing lines. Avoid plumbing runs and steamhead locations that can come in contact with bathers.
    (Items 5-7)

  5. DO NOT install steambath generator or plumbing lines in unheated attic or any locations where water could freeze and cause pipes to rupture and cause property damage.

  6. Install steambath generator on a solid and level surface. Provide supports under steam generator when wall mounting. Keyhole slots are provided for wall mounting.
    Insure the steam generator is properly secured and level when mounting with keyhole slots to prevent damage to the steam generator.

  7. Install steambath generator in an upright position only to prevent damage to the generator.
    IMPORTANT NOTES: (Items 8-12)

  8. Install anti-water hammer device as necessary.

  9. Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing. See page 10.

  10. Provide unions as required to facilitate installation and disconnection of piping.

  11. MrSteam controls can be located inside the steam room or on the outside of the steam room. See the Control Installation Manual for your specific control package for specific details.

  12. The MS series of steam generators are for residential use only. Commercial or other nonresidential applications void the warranty and may adversely affect product performance and may represent a safety hazard.

MrSteam Generators (inclusive of the iTempo, AirTempo and iSteam series Controls) are CE and UL listed.
Suitable for operation in ambient not exceeding 45 °C (113° F)

TYPICAL MrSteam INSTALLATION

Drawings for illustrative purposes only.
Consult with qualified designer, architect or contractor for steam room construction details.
MrSteam 104522MS Steam Sauna Bath - TYPICAL MrSteam
INSTALLATION **** To avoid unintentional steambath operation, do not locate the control where other controls, accessories, shower heads, valves, body sprays or similar within the shower could cause confusion or interfere with the MrSteam control’s intended use and function.

MrSteam logoFeel Good Inc.
PUR 100200E Rev 6.21
Sussman-Automatic Corp®
hello@mrsteam.com
www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 1 800 76 STEAM
9410 S. La Cienega Blvd.
Inglewood CA 90301 1 800 72 STEAM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals