Roth Touchline SL Wireless system Installation Guide
- June 10, 2024
- Roth
Table of Contents
- Roth Touchline SL Wireless system
- Product Information
- Product Usage Instructions
- Roth Touchline® SL Repeater
- System oversight
- Registration of Foor sensor
- Roth Touchline® SL repeater between Smart Home components and master –
- Roth Touchline® SL system with several repeaters in sequence – Only for
- Roth Touchline® PL mix system with repeater between thermostats and
- Roth Touchline® PL mix system with repeater between oor sensor and
- Roth Touchline® PL Controller 2 Ch mix system with repeater between
- Roth QuickStop Sensor 2 system with repeater between wireless sensor and
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Roth Touchline SL Wireless system
Product Information
The product described in this user manual is the Roth Minishunt Plus, which includes a Repeater used to extend the communication range between thermostats and control units. The product also includes a QuickStop Sensor 2 and a Floor Sensor for use in floor heating systems. The user manual provides instructions for installation and registration of the Repeater, as well as conguration of the master and expansion modules.
Product Usage Instructions
Installation: Connect the Repeater to the power supply and press the registration button on the Repeater. The registration indicator out will be permanently on and the registration indicator in will start flashing. To register a Room thermostat or Floor sensor, press the registration button on the backside of the device. If installing a Room thermostat, follow the registration process on the Controller to register the Repeater to the same zone as the Room thermostat. If installing a Floor sensor, follow the registration process on the Controller to register the Repeater to the zone.
Registration and Configuration of Repeater: In a system where a repeater is needed between the master and one or more expansion modules, configure the master unit to the repeater before signing up for the expansion module. This will ensure proper communication between the two units. To register an expansion module for a master unit via repeater, select Master module on the extension controller, select Registration, and press Yes.
The Roth Touchline® SL repeater can be used for a number of Roth products, Roth Touchline® SL, Roth Touchline® PL, Roth wireless control for Minishunt Plus and Roth QuickStop Sensor 2. The repeater is used if there is too long a distance between a transmitter and a receiver or in diffcult transmitter / receiver conditions. In a system, you can register several different units for one or more repeaters, however max. 20 units per repeater. You can mix both expansion module, thermostats, smart home components and QuickStop Sensor via one or more repeaters. Max 2 repeaters in series When registering a repeater, there must be a maximum of 10 meters between the receiver (control unit), the repeater and the transmitter (thermostat/sensor), registration, place the repeater midway between the transmitter location and the receiver. Afer registering the repeater, the signal strength between the repeater and the control end is shown in the display on the control unit, only Roth Touchline® SL and Roth Touchline® PL apply. The registered room thermostat, smart home component or sensor, now only works via the repeater. Test evt. the repeater function by changing the setpoint on the room thermostat, or making the Roth QuickStop Sensor damp on the underside – diode B on the repeater will fash briefy, indicating that the signal has been received and forwarded. On the control unit you can check that the setpoint has changed and on the Roth QuickStop sensor control unit it will give a “beep” sound, light red and close the valve.
Roth Touchline® SL Repeater
System oversight
Controller
Roth Minishunt Plus Roth QuickStop Sensor 2 Roth Touchline® SL Repeater
restoring factory settings Repeater between thermostats and control units.
Connect the
Repeater to the power supply – power indicator (A) will light up. Press the
registration button (E) on the Repeater. The registration indicator out (D)
will now be permantly on and the registration indicator in (C) will start
fashing.) Press the registration button on the backside of the Room thermostat
or Floor sensor. The registration indicator in (C) will now change to be
permanently on and the registration indicator out (D) will start flashing
.Press the
registration button on the backside of the Room thermostat or Floor sensor.
The registration indicator in (C) will now change to be permanently on and the
registration indicator out (D) will start flashing.If installing a Room thermostat, follow
the registration process on the Controller to register the Repeater to the
same zone as the Room thermostat
was registered to. When the Repeater has been registered all indicator
lights (A,B,C,D) on the repeater will ash simultaneously for 5 seconds. The
Controller will
display the message ”Sensor registered”.
Registration of Foor sensor
Connect
the Repeater to the power supply – power indicator (A) will light up. Press
the registration button (E) on the Repeater. The registration indicator out
(D) will now be permantly on and the registration indicator in (C) will start
flashing.
Floor sensor type “Touchline® SL room thermostat with wired foor sensor” –
HVAC No. 7466397525
Check that the room thermostat is registered to the repeater before
registration of foor sensors. When registering a cable floor sensor on the
Standard room thermostat, the button must to be pushed briefy twice. The
registration indicator in (C) will now change to be permanently on and the
registration indicator out (D)will start flashing.If installing a Floor
sensor, follow the registration process on the Controller to register the
Repeater to the zone.
If installing a Floor sensor, follow the registration process on the
Controller to register the Repeater to the zone.
Registration
and configuration of repeater between master and expansion module In a system,
one may need a repeater between the master and one or more expansion modules.
It is important to configure the master unit to the repeater before signing up
for the expansion module, as this will ensure that all communication is
properly exchanged between the two units.
Configure the Roth Touchline® SL repeater with the Roth Touchline® SL
master
Connect the repeater to 230V voltage, the power diode will light up (A). Press
and hold the registration button (E) on the repeater until the LEDs run from
side to side. On the master select “Fitters menu”, Repeater Configuration, Do
you want to configure? Confirm with “Yes” If the configuration is successful,
the repeater flashes 5 times and the master confirms the setup. If several
repeaters are required in extension of each other between the master and the
expansion module, the above procedure must be repeated on all repeaters!
Registration
of expansion module for master unit via repeater On the extension controller,
select “Master module”. Select “Registration” and press “Yes”. Press the
register button (E) on the repeater. The registration LED “out” (D) will now
light up constantly and the registration LED “in”(C) will flash. Within 30
seconds, the registration LED “in” (C) starts to light up constantly and the
registration LED “out” (D) will flash. On the master unit, select “Additional
modules”. You can connect up to 4 slave units to a master. Select
“Registration” and press “Yes”. Once the devices have found each other, the
LEDs on the repeater flash 5 times, then the LEDs in the repeater turn of,
with the exception of “Power”.
Roth Touchline® SL repeater between Smart Home components and master –
Only for Roth Touchline® SL.
Setting up repeaters in between Smart Home components and master. First connect the repeater to 230V voltage, the power diode will light up (A). Press the register button (E). The registration LED “out” (D) will now light up constantly and the registration LED “in” (C) will flash. Press the registration button on the devices.
On the master, select “Windows sensor” or “Radiator actuators”. You can connect up to 6 smart home devices per. channel. Select “Registration” and press “Yes” When the units have found each other, the LEDs on the repeater flash 5 times, after which the LEDs go out, with the exception of “Power”.
Roth Touchline® SL system with several repeaters in sequence – Only for
Roth Touchline® SL.
Setting up
repeaters in series (56)
Connect the rst repeater to 230V voltage, the power diode will light up (A).
Press the register button (E) on the repeater. The registration LED “out” (D)
will now light up constantly and the registration LED “in” (C) will flash.
Thermostat (57)
Press the registration button on the back of the room thermostat.
Extension module unit (58 )
Remember to configure all repeaters first, see page 9. On the expansion
module, select “Master module”. Select “Registration” and press “Yes”.
SmartHome devices (59+60)
Press the registration button on the desired device.
An extra repeater (60)
Connect the next repeater to 230V voltage, the power diode will light up (A).
Press the register button (E) on the repeater. The registration LED “out” (D)
will now light up constantly and the registration LED “in” (C) will flash.
Within 30 seconds, the registration LED “in” (C) starts to light up constantly
and the registration LED “out” (D) will flash. When the thermostat/ zone is
confirmed on the master control unit, the LED stops flashing and the repeater
switches of all LEDs, except “Power”.
Register the unit on the master unit in the same way as without a repeater. Example of registering a floor sensor.
Roth Touchline® PL mix system with repeater between thermostats and
control units.
Connect the Repeater to the power supply – power indicator (A) will light up.
Press the registration button (E) on the Repeater. The registration indicator
“out” (D) will now be permantly on and the registration indicator “in” (C)
will start flashing. Press the registration button on the backside of the
Room thermostat If installing a Room thermostat, follow the registration
process on the Controller to register the Repeater to the same zone as the
Room thermostat
was registered to.
Roth Touchline® PL mix system with repeater between oor sensor and
control units
To be able to use a floor sensor, a room thermostat must be registered at the channel first.
Press the
registration button (E) on the Repeater. The registration indicator “out” (D)
will now be permantly on and the registration indicator “in” (C) will start
flashing. Floor
sensor type “Touchline® PL room thermostat with wired floor sensor” – HVAC no.
7466397525
First register the room thermostat to the control unit via the repeater. Then
register the floor sensor to the control unit via the repeater by pressing the
registration button on the back of the floor sensor. The registration LED in
(C) will now light up constantly and the registration LED out (D) will flash.
If installing
a Floor sensor, follow the registration process on the Controller to register
the Repeater to the zone. When the Repeater has been registered all indicator
lights (A,B,C,D) on reciever will flash simultaneously for 5 seconds. The
Controller will display the message ”Sensor registred”. The power indicator
(A) will be permaneltly on. The communication indicator (B) will flash very
shortly when the set temperature is changed from the Room thermostat and the
Controller will update the new set temperature on the display. Only register
devices that require a better signal in order to get the best range. The
signal strength displayed on the Controller is for the signal between the
Controller and the Repeater.
Roth Touchline® PL Controller 2 Ch mix system with repeater between
thermostats and control units.
Connect the Repeater to the power supply – power indicator (A) will light up. Press the registration button (E) on the Repeater. The registration indicator “out” (D) will now be permantly on and the registration indicator “in” (C) will start flashing.
When the room thermostat is registered to the repeater, the repeater must be registered to the desired channel on the control unit, press once for channel 1 and twice for channel 2 on the registration button on the left side of the receiver. Check on the receiver that joints Ch.1 /Ch.2 turn on when the room thermostats call for heat.
Roth QuickStop Sensor 2 system with repeater between wireless sensor and
control units.
Connect the Repeater to the power supply – power indicator (A) will light up. Press the registration button (E) on the Repeater. The registration indicator “out” (D) will now be permantly on and the registration indicator “in” (C) will start flashing.
Press the registration button inside the sensor. The registration LED on the repeater “in” (C) will now light up constantly and the registration LED “out” (D) will flash. When the sensor is registered to the repeater, the repeater must be registered to the control unit. Press and hold the tick button for approx. 5 seconds until the LED starts flashing blue slowly. When the installation of the sensor via the repeater is completed, the LED will light blue for approx. 10 seconds.
If you want to reset your repeater to the factory settings, do the following:
-
1. Press and hold Exit button for 10 seconds – the two outermost control lights will start flashing.
- Press Registration button all control lights will start flashing.
ROTH UK Ltd
1a Berkeley Business Park Wainwright Road Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com