AJAX 834-03-0003 Wireless Home Siren User Manual

June 5, 2024
ajax

**AJAX 834-03-0003 Wireless Home Siren User Manual

**

Functional elements

  1. Light indicator

  2. Siren buzzer covered with a fabric

  3. Smart Bracket attachment panel (perforated part is required for actuating the tamper in case of any attempt to tear off the siren from the surface)
    Functional elements

  4. QR code

  5. Tamper button

  6. Socket for connecting an outside-mounted light indicator

  7. On/off button

Operating Principle

The siren signiQcantly improves the eUciency of the security system, being the most operational means of response to the intrusion into a room. With a high probability, its alarm signal will be suUcient to frighten away the intruders.

The device is furnished with a loud buzzer – the sound of the siren can be heard from far. Subject to correct installation, it would be hard to dismount and  eactivate the actuated siren: the body is Qrm, the power supply is autonomous, and the on/off button will be blocked when the security system is set in the guard mode.

Connecting the Siren to the hub

Caution Icon The HomeSiren siren operates only with the Ajax security system. Up to 10 sirens may be connected to the Ajax hub.

Before starting connection:

  1. Following the hub instruction recommendations, install the Ajax Application on your smartphone. Create an account, add the hub to the application, and create at least one room.
  2. Go to the Ajax application.
  3. Switch on the hub and check the internet connection (via Ethernet cable and/or GSM network).
  4. Ensure that the hub is disarmed and does not start updates by checking its status in the mobile application.

 Only users with administrative privileges can add the device to the hub

How to connect the siren to the hub:

  1. Select the Add Device option in the Ajax application.

  2. Name the device, scan/write manually the QR Code (located on the body and packaging), and select the location room.

  3. Select Add — the countdown will begin.

  4. Switch on the device (by pressing on/off button for 3 seconds).
    Connect the siren

For the detection and interfacing to occur, the siren should be located within the coverage area of the wireless network of the hub (at a single protected object). If the device was already assigned to another hub, switch off HomeSiren and then perform the standard adding procedure.

Request for connection to the hub is transmitted for a short time at the time of switching on the device.

If the connection to the Ajax hub failed, the siren will switch off after 6 seconds. You may repeat the connection attempt then. To retry the connection, you do not need to turn off the device.

The siren connected to the hub will appear in the list of devices of the hub in the application. Update of the siren statuses in the list depends on the device inquiry time set in the hub settings, with the default value — 36 seconds.

States

Siren states can be found in the Ajax app:

  1. Go to the Devices tab.
  2. Select HomeSiren from the list.
Parameter Value
Temperature Temperature of the device. Measured on the processor and changes

gradually. Displayed in 1°C increment.  Acceptable error between the value in the app and temperature at the installation site: 2–4°C
Jeweller Signal Strength| Signal strength between the hub/range extender and siren.  We recommend installing the siren in places with the signal strength of 2-3 bars
Connection| Connection status between the hub/range extender and siren:

  • Online — the siren is connected to the hub/range extender
  • Offline — the siren is not connected to the hub/range extender

|
ReX range extender name| Displayed if the siren is working via a radio signal range extender
Battery Charge| Battery level of the device. Two states available:

Lid| The tamper mode of the device, which reacts to the detachment of or damage to the body
Alarm Volume| Volume level in case of alarm

  • Muted — the siren does not sound when the alarm is raised
  •  Quiet — 81 dB volume
  • Loud — 93 dB volume
  • Very loud — 105 dB volume
    The volume level is measured 1 m away from the siren

Alarm Duration, sec| Duration of the alarm sound: from 3 to 180 seconds
LED indication| LED indication of the siren settings:

  • Disabled — LED indication is off
  • Armed — the siren blinks only when alarm is enabled
  • Always — the siren blinks regardless

| of the state of the security system More about indication
Beep When Arming/Disarming| If active, the siren notifies you about the activation and deactivation the system of the guard mode by the LED and a short sound signal
Notify about switching the Night mode on/off| When enabled, the siren notifies you when the system is on and off the Night mode by flashing the LED and making a short beep
Beep on Entry/Exit delay| If activated, siren will beep delays (available in devices with firmware version 3.50 and later)
Notify about the entry/exit delay in the Night mode| If this option is enabled, the siren beeps to signal about an entry/exit delay in the Night mode
Chime on opening| When enabled, a siren notifies about opening detectors triggering in the Disarmed system mode   What is chime
Temporary Deactivation| Shows the status of the device: active, completely disabled by the user, or only notifications about triggering of the device tamper button are disabled
Firmware| Detector firmware version
Device ID| Device identifier
Device No.| Number of the device loop (zone)

Setting Up the Detector

To change the HomeSiren settings in the Ajax app::

  1. Select the hub if you have several of them or if you are using the PRO app.
  2. Go to the Devices tab.
  3. Select HomeSiren in the list.
  4. Go to Settings by clicking on the .
  5. Set the required parameters.
  6. Click Back to save the new settings

Setting

|

Value

---|---

First field

| Siren name that can be edited. The name of device you can see at notifications in the event feed. The name can contain up to 12 Cyrillic characters or up to 24 Latin symbols
Room| Selecting the virtual room to which StreetSiren DoubleDeck is assigned. The room name you can see at notifications in the event feed
| Selecting the group to which the siren is assigned. You can select one or all groups:

  • When assigned to a group , the siren and its indication are related to alarms and events of this group

Alarms in Group Mode|

  • When attached to all groups, the siren and its indication are related to alarms and events of all groups in the system

Regardless of the group selected, the siren will respond to Night Mode activation and alarms Learn more

Alarm Volume| Volume level in case of alarm:

  • Muted — the siren does not sound when the alarm is raised
  • Quiet — 81 dB volume
  • Loud — 93 dB volume
  • Very loud — 105 dB volume

The volume level is measured 1 m away from the siren

Alarm Duration, sec| The setting determines how long the siren sounds, if the alarm is activated (from 3 to 180 seconds per each actuation)
LED indication| LED indication of the siren settings:

  • Disabled — LED indication is off
  • Armed — LED blinks once every 2 seconds only when the system is armed
  • Constantly — LED blinks once every 2 seconds regardless of the mode state

| More about indication
Beeps Settings| Opens the siren notification settings. A detailed description of the settings is available below
Volume Test| Switches the device to the volume test mode What is Volume Level Test
Jeweller Signal Strength Test| Switching the siren to the Jeweller signal strength test mode. The test allows you to check the signal level between the hub and HomeSiren and determine the optimal installation location

What is Jeweller Signal Strength Test

Signal Attenuation Test| Switches the siren to the signal fade test mode (available in devices with firmware version 3.50 and later) What is Attenuation Test
User Guide| Opens the HomeSiren User Manual
| Allows the user to disconnect the device without removing it from the system.  Two options are available:

  • No — the device operates normally and transmits all events
  • Entirely — the device will not execute system commands or participate in

Temporary Deactivation| automation scenarios, and the system will ignore device alarms and other notifications

  • Lid only — the system will ignore only notifications about the triggering of the device tamper button

Learn more about temporary deactivation of devices

Unpair Device| Disconnects the siren from the hub and deletes its settings

Siren beep settings

Arming/Disarming| When this option is enabled, the siren warns of arming and disarming by lighting of the LED frame and by a short beep
---|---
Night mode Activation/Deactivation| If enabled, the siren alerts you by backlighting the LED frame and a short beep when arming and disarming the system from the Night mode

What is Night mode

Entry Delays| If this option is enabled, the siren beeps to signal about an entry delay

What is Delay When Entering/Leaving

Exit Delays| If this option is enabled, the siren beeps to signal about an exit delay

What is Delay When Entering/Leaving

Entry Delays in Night Mode| If this option is enabled, the siren beeps to signal about an entry delay in the Night mode

What is Night mode What is Delay When Entering/Leaving

Exit Delays in Night Mode| If this option is enabled, the siren beeps to signal about an exit delay in the Night mode

What is Night mode What is Delay When Entering/Leaving

Chime on opening| When enabled, the siren beeps 1 to 4 times to indicate that opening detectors in the Disarmed system mode were triggered

What is ChimeHow to set up Chime

| Selecting the volume level of the siren at the time of notification on arming/disarming or delay when entering/leaving and opening:
Beep volume|

  • Quiet — 80 dB volume
  • Loud — 93 dB volume Very
  • loud — 98 dB volume

The volume level was measured 1 m away from the siren

Setting up the processing of detector alarms

Through the Ajax app, you can conQgure which detector alarms can activate the siren. This can help to avoid situations when the security system notiQes of LeaksProtect detector alarm or any other device alarm. The parameter is adjusted in the detector or device settings:

  1. Sign in to the Ajax app.
  2. Go to the Devices    menu.
  3. Select the detector or device.
  4. Go to its settings and set the necessary parameters for activating the siren.

Setting the tamper alarm response

The siren can respond to the tamper alarm of devices and detectors. The option is disabled by default. Note that the tamper reacts to the opening and closing of the body even if the system is not armed!

What is A tamper

For the siren to respond to tamper triggering, in Ajax app:

  1. Go to the Devices   menu.
  2. Select the hub and go to its settings .
  3. Select the Service menu.
  4. Go to Siren Settings.
  5. Enable the Alert with a siren if the hub or detector lid is open option.

Setting the response to pressing the panic button in the Ajax app

The siren can respond to pressing the panic button in Ajax apps. Note that the panic button can be pressed even if the system is disarmed!

For the siren to respond to pressing the panic button:

  1. Go to the Devices     menu.
  2. Select the hub and go to its settings .
  3. Select the Service menu.
  4. Go to Siren Settings.
  5. Enable the Alert with a siren if in-app panic button is pressed option.

Setting the siren after-alarm indication

Setting the Siren

The siren can inform about triggerings in the armed system by means of LED indication.

The option functions as follows:

  1. The system registers the alarm.
  2. The siren plays an alarm (duration and volume depend on settings).
  3. The siren LED and external LED (if connected) blinks twice (about once every 3 seconds) until the system is disarmed.

Thanks to this feature, system users and security companies patrols can understand that the alarm has occurred.

Caution Icon The siren after-alarm indication does not work for always active detectors, if the detector was triggered when the system was disarmed.

  1. Go to siren settings:
    • Hub → Settings → Service → Siren Settings
  2.  Specify what events the sirens will inform about by double blinking before the security system is disarmed:
    • ConQrmed alarm
    • UnconQrmed alarm
    • Lid opening
  3. Select the sirens needed. Go back to Siren Settings. The set parameters will be saved.
  4. Click Back. All values will be applied.

 HomeSiren with Qrmware 5.55.2 and later supports this function.

How to set Chime

Chime is a sound signal that indicates the triggering of the opening detectors when the system is disarmed. The feature is used, for example, in stores, to notify employees that someone has entered the building.

Notifications are configured in two stages: setting up sirens and setting up opening detectors.

Learn more about Chime

Home Siren with from ware 5.55.1.0 and later supports this function.

Siren settings

  1. Go to the Devices menu.

  2. Select the siren.

  3. Go to its settings by clicking the gear icon in the upper right corner.

  4. Go to the Beeps Settings menu.

  5. Scroll down and enable the Chime on opening option in the Beep when disarmed category.

  6. Set the volume of the notiQcations. 3 options are available:

    • Quiet (80 dB at a distance of 1 m).
    • Loud (93 dB at a distance of 1 m).
    • Very loud (98 dB at a distance of 1 m).
      Caution Icon The specified Beep volume also applies to the volume of siren  Notifications when arming/disarming and for the entry/exit delays.
  7. Click Back to save the settings.

  8. Repeat steps 2–7 for other sirens on which you want to enable the notifications.

Detectors settings

  1. Go to the Devices menu.
  2. Select the detector.
  3. Go to its settings by clicking the gear icon in the upper right corner.
  4. Go to the Chime Settings menu.
  5. Select the events to be notiQed by the siren:
    • If a door or a window is open.
    • If an external contact is open (available if the External Contact option is enabled).
  6. Select the chime sound (siren tone): 1 to 4 short beeps. Once selected, the Ajax app will play the sound.
  7. Click Back to save the settings.
  8. Repeat steps 2–7 for other detectors on which you need to enable the notiQcations.

Indication

Event Indication
Alarm Emits an acoustic signal (the duration depends on the settings) and all

LED signaling ceases
An alarm was detected in the armed system (if after-alarm indication is enabled)| The siren LED and external LED (if connected) blinks twice approximately every 3 seconds until the system is disarmed. The indication turns on after the siren has completely played the alarm signal configured in settings
Switching on the device| LED lights up once
Switching off the device| LED will light up for 1 second, then blink three times
Registration failed| LED lights up and goes out, then the siren switches off
Security system set in the armed mode (if the indication is activated)| Blinks once with a LED and emits a short sound signal
Security system is disarmed (if the indication is activated)| Blinks twice with a LED and emits two short sound signals
Siren in the armed mode (if the indication is activated)| LED lights up for a short time every 3 seconds
Battery low| LED smoothly lights up and goes out when the system is armed or disarmed (if the indication is activated), the tamper is actuated or alarm is given

Performance testing

The Ajax security system allows conducting tests for checking the functionality of connected devices.

The tests do not start straight away but within a period of 36 seconds when using the standard settings. The test time start depends on the settings of the devices scanning period (the paragraph on “Jeweller” settings in hub settings).

Volume Level Test

Jeweller Signal Strenghth Test

Attunuation Tewst

Installing the Siren

Location of the HomeSiren determines its remoteness from the hub and presence of any obstacles between the devices, hindering the radio signal and sound transmission: walls, inserted joors, largesize objects located within the room.

The device developed only for indoor use.

 Check the signal level at the installation location.

The communication r ange is up to 2000 meters if there are noobstacles. Please consider it when choosing an installation place for HomeSiren.

If the signal level is one division, we cannot guarantee stable operation of the security system. Take possible measures to improve the quality of the signal! As a minimum, move  the device — even 20 cm shift can signiQcantly improve the quality of reception.

If after moving the device still has a low or unstable signal strength,
use a radio signal range extender.

Recommended installation height — 2.5 meters and more. This will complicate the access to the device for intruders in case of intrusion.

Installation process

  1. Fix the SmartBracket panel on the surface using bundled screws. After selecting other attachment hardware, make sure that they do not damage or deform the panel.

The double-sided adhesive tape may be only used for temporary attachment of the siren. The tape will run dry in course of time, which may result in the falling and damage of the device.

  1. Put the siren on the SmartBracket panel and turn it clockwise. When installing in the attachment panel, the tamper will switch and the siren will blink with a LED.

If the light indicator of the siren is not actuated after installation in SmartBracket, check the tamper mode in the Ajax Security System application and then the Qxing tightness of the device on the panel.

In case of any attempt to dismount the siren, you will receive the notiQcation.

Do not install the siren:

  1. outside the premises (outdoors)
  2. in places where the acoustic signal will be attenuated (inside furniture, behind thick curtains, etc.)
  3. nearby any metal objects or mirrors causing attenuation and screening of the signal
  4. within any premises with the temperature and humidity beyond the range of permissible limits
  5. closer than 1 m from the hub.

External LED connection

The outside-mount ed LED connected to the HomeSiren is paralleled with the built-in LED of the device and completely repeats its indication.

For connection, use the contact on the rear side of the siren body and observe the polarity during the connection. Black terminal wire — “+” contact.

Outlet power supply: 3 V, 10 mA

Siren Maintenance and Battery Replacement

Check the operational capability of the HomeSiren on a regular basis.

Clean the siren body from dust, spider web and other contaminations as they appear. Use soft dry napkin suitable for equipment maintenance.

Do not use for cleaning the siren any substances containing alcohol, acetone, gasoline and other active solvents.

The batteries installed in the siren ensure up to 5 years of autonomous operation (with the inquiry frequency by the hub of 1 minute) or at least 6 hours of the buzzer sound. If  the battery is discharged, the security system will send respective notices and the LED will smoothly light up and goes out when the armed mode is activated.

How long Ajax device operate on batteries, and what affect this

Battery Replacement 

Tech specs

Type of notification Acoustic and LED
Sound notification volume 81 – 105 dB at a distance of 1 m (adjustable)
Operating frequency of the buzzer 3.4 ± 0.5 kHz
Tamper protection Yes
Radio communication protocol Jeweller  [ _Learn

more_](https://support.ajax.systems/en/jeweller-radio-protocol/)
Radio frequency band| 866.0 – 866.5 MHz

868.0 – 868.6 MHz

868.7 – 869.2 MHz

905.0 – 926.5 MHz

915.85 – 926.5 MHz

921.0 – 922.0 MHz

Depends on the region of sale.

Compatibility| Operates only with all Ajax hubs, and   radio signal range extenders
Maximum RF output power| Up to 25 mW
Radio signal modulation| GFSK
Radio signal range| Up to 2,000 m (any obstacles absent)
|
Battery supply| 2 × CR123A, 3 V
Battery life| Up to 5 years
Socket for connecting an external light indicator| Yes (power supply 3 V, 10 mA)
Body protection level| IP50
Installation method| Indoors
Operating temperature range| From -10°С to +40°С
Operating humidity| Up to 75%
Overall dimensions| 75 × 76 × 27 mm
Weight| 97 g
Service life| 10 years
Certification| Security Grade 2, Environmental Class II in conformity with the requirements of EN 50131-1, EN 50131-4, EN 50131-5-3

Compliance with standard 

Complete Set

  1. Home Siren
  2. SmartBracket mounting panel
  3. Battery CR123A (pre-installed) — 2 pcs
  4. LED connection clamp
  5. Installation Kit
  6. Quick Start Guide

Declaimer

HomeSiren is a wireless home siren with the capacity up to 105 dB. Developed only for indoor use. It can be quickly installed and set up, is furnished with a LED (plus allows connecting an external LED), and can operate up to 5 years from a battery.

HomeSiren operates within the Ajax security system, by connecting via the protected Jeweller protocol to the hub . The communication range is up to 2,000 meters if there are no obstacles.

The siren is set up via a mobile application for iOS and Androidbased smartphones. The user is notified of all events through push notiQcations, SMS messages and calls (if activated).

Operates only with Ajax hubs Connection to ocBride Plus and uartBride integration modules is not provided.

The Ajax security system is self-sustaining, but the user can connect it to the central monitoring station of a private security company.

Buy home siren Home Siren

Warranty

Warranty for the “AJAX SYSTEMS MANUFACTU RING” LIMITEDLIABILITY COMPANY products is valid for 2 years after the purchase and does not apply to the pre-installed battery

If the device does not work correctly, you should Qrst contact the support service — in half of the cases, technical issues can be solved remotely!.

The full text of the warranty 

User Agreement

Technical support:support@ajax.systems

Subscribe to the newsletter  bout safe life. No spam

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals