USE AND MAINTENANCE
The interior is constructed of mirrored glass and aluminum. Use only a damp cloth to clean. Ammonia or vinegar-based cleansers can damage mirrors. When cleaning, spray the cloth, not the mirror, or surrounding surfaces. Do not use abrasive cleansers on any part of the light fixture.
EXTENTED WARRANTY SERVICE
Please send your Purchasing Order No. to
service@getprohome.com to register extended 2
years warranty on hardware components. We pride ourselves with a 100% Customer
Satisfaction Guarantee.
We are confident in our products and stand behind them 100%. Just reach to us
with any questions or concerns and we will be happy to help in less than 24
hours!
IMPORTANT NOTICE
We will guarantee all customer benefit. The products we ship out are brand
new. Please check carefully before installation, compare all parts with the
parts listed in the package contents section. If any part appears missing or
damaged, do not install. Contact customer service by E-mail:
service@getprohome.com Send us the pictures or video, we promise will response
to you with 24 hours. We will decide send you spare parts or deliver a
replacement by free.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed, including the following:
WARNING: To reduce the risk of burns,fire,electric shock or injury to persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manutacturer. Never drop or insert any object into any opening.Do not use outdoors.
WARNING : Risk of electric shock. Connect this furnishing to a properly grounded circuit only. See grounding instructions.
CAUTION : Maximum shelf load 34lbs/15.4kg
ELECTRIC CONNECTIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN.
WARNING : Shut off power before wiring the cabinet. Requires 120 VAC 20 Amp GFI protected Circuit.
GROUNDING INSTRUCTIONS:
CAUTION : This product must be connected to a grounded metal permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product.
WARNING : An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.
The electric wire comes through the access hole on the top of the cabinet, exact location of access hole variess depending on the product models. Please refer to the actual product for the exact location.
HARDWARE AND TOOLS
-
Step 1 Level and mark the cabinet’s location on the wall. Connect the wire to Junction Box inside the wall.
-
Step 2Fix Top Mounting Bracket on the Wall
Measure the distance between the 3 holes in the Top Mounting Bracket. -
Step 3 Hanging the Cabinet on the top mounting bracket. Make sure top brackets are locked in the grooves.
-
Step 4 Move the cabinet to the right position and screw in the bottom supportting bracket and fix it.
-
Step 5 Optional Door Adjustment
OPTIONAL DOOR ADJUSTMENT
Doors may need to be adjusted after the initial shipping of the cabinet. The
cabinet doors have a three-way adjustment feature. Height, side-to side, level
and depth can be adjusted. With the hinge slightly closed you can access the
middle screw for up/down adjustment. With the hinge fully extended you can
access the front and back screws. These screws will move the door side to side
and in and out
Insert clear snap in shelf clips into holes on the sides of the cabinet. Install the glass shelf. Adjust the height according to your preference.
Fix Top Mounting Bracket on the Wall
Measure the distance between the 3 holes in the Top Mounting Bracket. Hanging the Cabinet on the top mounting bracket. Make sure top brackets are locked in the grooves.
Move the cabinet to the right position and screw in the bottom supporting bracket and fix it.
Product Component Parts
DIY YOUR BATHROOM SPACE
More Options Depends on You
- After power on, the button shows blue and it is in waiting state
- Click the light button to turn on and the color changes to white
- Click again to change the light color
- Click the fourth time to turn off the light
- Long press to make the light gradually dims
- Long press again and the light gradually brightens
- Touch key to tu rn on/off defogging function.
- When defogger is on, the button should be in blue color.
- Defogger will turn off automatically after 60 minutes, touch the key to turn on again.