Sensolus M 4201 Magnetic Sensor Sense Instruction Manual

June 11, 2024
sensolus


Sense M 4201 installation manual

A sensor and a magnet

The magnetic sensor Sense M 4201 is shipped with a corresponding MAG L 0001.
To work correctly it is important that both sensor and the magnet are positioned precisely.
If they are not correctly aligned the closed state will never be detected. The sensor can be glued to any flat surface. This is a permanent solution. Sensolus recommends the use of Sabatack 780 or Tech 7 to glue materials.

We recommend that the head of the screw does not protrude when you fasten the magnet with screws. The magnet can be glued to any flat surface. Use glue when drilling holes is difficult.

Advice for the magnet and sensor setup

Sensor orientation
The sensor can be turned around it’s central axis, this will have no impact on the working of the sensor.

Front facing installation is recommended
The recommended installation is the magnet frontal facing the sensor with no distance between them. This means sensor and magnet touch each other to detect the ‘closed’ status.
The maximum distance between the sensor and the magnet to still detect the ‘closed’ status is 5 mm. Installation on brackets might be needed to create a perfect installation. Side by side installation
When installing the sensor and magnet side by side they have to touch each other to detect the ‘closed’ status.
No distance between sensor and magnet is accepted to ensure proper functioning.

90° angle installation
When installing the sensor and magnet at an angle of 90(degrees sign) they have to touch each other to detect the ‘closed’ status. No distance between sensor and magnet is accepted to ensure proper functioning.

www.sensolus.com 
info@sensolus.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals