NINGBO Freedom-Air 2.0 Dual Remote Wireless Interchangeable Inflator Pump Instruction Manual

June 11, 2024
Ningbo

NINGBO Freedom-Air 2.0 Dual Remote Wireless Interchangeable Inflator

Pump

Product Information

The Freedom-Air 2.0 Dual Remote Wireless Interchangeable Inflator Pump is a highly efficient and versatile pump that can be used for a variety of inflatables such as mattresses, pool toys, and sports equipment. The pump comes with two interchangeable nozzles and can be operated wirelessly using the remote control. It has two memory settings, Memory 1 and Memory 2, which can be customized to set the pressure level of your choice.

Operation Instructions

  1. Plug in the pump to a power source.
  2. The power indicator will start flashing slowly for 30 seconds and then stop flashing.
  3. Attach the nozzle of your choice to the pump.
  4. Turn on the remote control by pressing the power button.
  5. Select the memory setting you want to use by pressing the corresponding button on the remote control (Memory 1 or Memory 2).
  6. Use the left pressure scroll bar on the remote control to set the desired pressure level. The display will show “SOFT” for Memory 1 and “FIRM” for Memory 2.
  7. Press the button on the remote control to start inflating. The pump will automatically stop when it reaches the set pressure level.
  8. To stop inflating manually, press the stop button on the remote control.

FCC Caution

This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.
  3. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note

This equipment has been tested and found to comply with the limits for a Class B digital device.

To reduce the risk of interference, follow these guidelines:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RF Exposure Requirement

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Operation Instruction

  1. NINGBO-Freedom-Air-2.0-Dual-Remote-Wireless-Interchangeable-Inflator-Pump-fig-1 Plug in the pump, and the power indicator will flash slowly for 30 seconds and then stops flashing which means the system is in standby mode. Within 30 seconds, press any button to light LCD, then pressing the FIRM button for 3 seconds will start to resync. LCD will display SU when the pump and remote are synced again successfully and enter standby mode. The power indicator will flash when the pump is working.
  2. Press any button to light LCD for operation. If there is no operation after 15 seconds LCD will turn off automatically to save battery life.
  3. LEFT/RIGHT: press the LEFT/RIGHT button to select the left side or right side air chamber for further operation. LCD will show L or R accordingly.
  4. FIRM: press the FIRM button one time, and the pump will be activated to inflate the pressure level shown on LCD will increase relative to the pressure in the air chamber, and the scroll bar will scroll up to show that the pressure is increasing. At any time during the period of inflation, pressing any button will stop the inflation. Or when the pressure reaches the maximum ( 50 on LCD), the inflation will stop automatically.
  5. SOFT: press the SOFT button, and the pump will be activated to deflate the pressure level shown on LCD will decrease relative to the pressure in air chamber, and the scroll bar will scroll down to show that the pressure is decreasing. At any time during the period of deflation, pressing any button will stop the deflation. Or when the pressure reaches the minimum ( 0 on LCD), the de flation will stop automatically.
  6. Memory: press the MEM1 or MEM2 button, LCD will show M1 or M2 and the pump will be activated to inflate or deflate until the pressure in air chamber reaches the level memorized. When the pump is inflating or deflating to the level memorized, pressing any button will still stop inflation or deflation.
  7. Setting Memory Level: when LCD shows a pressure level readout, before or after inflation or deflation, press and hold the “MEM1” or “MEM2” button for 3 seconds, M1 or M2 indicator will flash and the current pressure level will be kept as a new memory level. The memory level for left or right side air chamber can be set in the same way, to be the same or different. The default MEM1 level is 25mmHg (“25” on LCD). The default MEM2 level is 20 mmHg (“20” on LCD).
  8. Smart Support Technology SST is enabled by default to maintain the level last selected or memory setting for continuous comfort. SST may be disabled/enabled by pressing “ LEFT/RIGHT ” for 3 seconds then, while still pressing the “ LEFT/RIGHT” button, quickly pressing the “ button at which time LCD will display F1, at this time pressing “ LEFT/RIGHT will turn SST off or on. When disabled SST symbol will not show in the LCD display.
  9. Actual Pressure Check: press and hold LEFT/RIGHT for 3 seconds then, while still pressing the LEFT/RIGHT L button, quickly press the MEM2 button, LCD will display the actual pressure in air chamber and the pressure scroll bar will flash. The display of actual pressure will turn off after 15 seconds automatically or by pressing any button.
  10. Special Note: A) The Max. pressure is 50mmHg. B) The pump will automatically stop after working continuously for 10 minutes. C) Real-time Pressure readout has a 10 mmHg margin when starting in flation, however, the real-time pressure will be displayed directly when it is lower than 10 mmHg. After checking the actual pressure, the actual pressure will be treated as the last set level. D) Air Chamber Dimension Detection: to display the pressure level in air chamber accurately, Freedom Air 2.0 Wireless Inflator Pump has a function to measure and record air chamber dimensions automatically when it works in the first few times. Such a measurement can also be done manually by pressing the LEFT/RIGHT button for 3 seconds then, while still pressing the LEFT/RIGHT button, quickly pressing the SOFT button at which time LCD will display AD and the inflator pump will start the measurement. It takes about 10 minutes to do such a measurement.
  11. Troubleshooting: A) Range: wireless remote control range is 15-30′ (5-10m) so if out of range the controller will show “Er”. B) Sync: while remotes are synced before delivery, if “Er” continues to show on LCD or when the wireless remote is replaced, please resync. To resync, disconnect the power to the pump, then power it on again, the power indicator will flash slowly for 30 seconds. Within 30 seconds, press any button to light LCD, then press down the “FIRM” button for 3 seconds, and when the LCD shows “SU” the pump and remote are synced again successfully. C) Batteries: The remote is powered by three AAA LR03 1.5V batteries. When the battery power is low, the LCD will show low battery capacity alert so please replace the batteries. If the remote will not be used for a long time, please remove the batteries.

FCC Caution

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.
  3. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals