Vaillant VU ecoTEC plus Gas Condensing Wall Hung Boiler User Manual
- June 9, 2024
- Vaillant
Table of Contents
- Safety
- Notes on the documentation
- Product description
- Operation
- Operating concept
- Basic display
- Menu display
- Adjustment and display levels
- Cabinet-type casing
- Opening the isolator devices
- Starting up the product
- Switching on the product
- Setting the language
- Setting the heating flow temperature
- Setting the hot water temperature
- Switching Comfort mode on and off
- Activating the shift-load cylinder
- Setting the target cylinder temperature
- Switching off the product’s functions
- Guaranteeing the correct filling pressure of the heating system
- Protecting the heating installation against frost
- Troubleshooting
- Care and maintenance
- Decommissioning
- Recycling and disposal
- Guarantee and customer service
- Appendix
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Vaillant VU ecoTEC plus Gas Condensing Wall Hung Boiler
Safety
Action-related warnings
Classification of action-related warnings
The action-related warnings are classified in accordance with the severity of
the possible danger using the following warning signs and signal words:
Warning symbols and signal words
Danger!
Imminent danger to life or risk of severe personal injury
Danger!
Risk of death from electric shock
Warning.
Risk of minor personal injury
Caution.
Risk of material or environmental damage
Intended use
There is a risk of injury or death to the user or others, or of damage to the product and other property in the event of improper use or use for which it is not intended.
The product is intended as a heat generator for closed heating installations and for hot water generation.
Intended use includes the following:
- observance of the operating instructions included for the product and any other system components
- compliance with all inspection and maintenance conditions listed in the instructions.
This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children must not play with the product. Cleaning and user maintenance work must not be carried out by children unless they are supervised.
Any other use that is not specified in these instructions, or use beyond that specified in this document shall be considered improper use. Any direct commercial or industrial use is also deemed to be improper.
Caution.
Improper use of any kind is prohibited.
General safety information
Installation by competent persons only
The installation, inspection, maintenance and repair of the product, as well as the gas ratio settings, must only be carried out by a competent person.
Danger caused by improper operation
Improper operation may present a danger to you and others, and cause material damage.
- Carefully read the enclosed instructions and all other applicable documents, particularly the “Safety” section and the warnings.
- Only carry out the activities for which instructions are provided in these operating instructions.
Risk of death from escaping gas
What to do if you smell gas in the building:
- Avoid rooms that smell of gas.
- If possible, open doors and windows fully and ensure adequate ventilation.
- Do not use naked flames (e.g. lighters, matches).
- Do not smoke.
- Do not use any electrical switches, mains plugs, doorbells, telephones or other communication systems in the building.
- If it is safe to do so, close the emergency control valve or the main isolator.
- If possible, close the gas isolator cock on the product.
- Warn other occupants in the building by yelling or banging on doors or walls. Leave the building immediately and ensure that others do not enter the building.
- Notify the gas supply company or the Emergency Service Provider +44 (0) 800 111999 by telephone once you are outside of the building.
Risk of death due to a blocked or leaking flue gas pipe
What to do if you smell flue gas in the property:
- Open all accessible doors and windows fully to provide ventilation.
- Switch off the product.
- Inform a competent person
Risk of death due to explosive and flammable materials
- Do not use or store explosive or flammable materials (e.g. petrol, paper, paint) in the installation room of the product.
Risk of death due to changes to the product or the product environment
-
Never remove, bridge or block the safety
devices. -
Do not tamper with any of the safety
devices. -
Do not damage or remove any seals on
components. -
Do not make any changes:
– The product itself
– to the gas, air, water and electricity supplies
– to the entire flue gas installation
– to the entire condensate drain system
– to the expansion relief valve
– to the drain pipework
– to constructional conditions that may affect the operational reliability of the product
Risk of poisoning caused by insufficient supply of combustion air
Conditions: Open-flued operation
- Ensure that there is a sufficient supply of combustion air.
Risk of corrosion damage due to unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning agents, paint, adhesives, ammonia compounds, dust or similar substances may lead to corrosion on the product and in the air/flue pipe.
- Ensure that the supply of combustion air is always free of fluorine, chlorine, sulphur, dust, etc.
- Ensure that no chemical substances are
stored at the installation site.
Risk of material damage caused by frost
- Ensure that the heating installation always remains in operation during freezing conditions and that all rooms are sufficiently heated.
- If you cannot ensure the operation, have a competent person drain the heating installation.
Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all
- Never attempt to carry out maintenance work or repairs on your product yourself.
- Faults and damage should be immediately rectified by a competent person.
- Adhere to the maintenance intervals specified.
Notes on the documentation
Observing other applicable documents
- You must observe all operating instructions enclosed with the system components.
Storing documents
- Keep this manual and all other applicable documents safe for future use.
Applicability of the instructions
These instructions apply only to:
Product article number
| Article number| Gas Council Number
---|---|---
VU 126/5-5 (H-GB)
ecoTEC plus 612| 0010021828| 41-694-20
VU 156/5-5 (H-GB)
ecoTEC plus 615| 0010021829| 41-694-21
VU 186/5-5 (H-GB)
ecoTEC plus 618| 0010021830| 41-694-22
VU 186/5-5 (P-GB)
ecoTEC plus 618| 0010021831| 41-694-23
VU 246/5-5 (H-GB)
ecoTEC plus 624| 0010021832| 41-694-24
VU 306/5-5 (H-GB)
ecoTEC plus 630| 0010021833| 41-694-25
VU 306/5-5 (P-GB)
ecoTEC plus 630| 0010021834| 41-694-26
VU 386/5-5 (H-GB)
ecoTEC plus 637| 0010021835| 41-694-27
VUW 196/5-5 (H-GB)
ecoTEC plus 825| 0010021823| 47-044-83
VUW 246/5-5 (H-GB)
ecoTEC plus 832| 0010021824| 47-044-84
VUW 246/5-5 (P-GB)
ecoTEC plus 832| 0010021825| 47-044-85
VUW 286/5-5 (H-GB)
ecoTEC plus 838| 0010021826| 47-044-86
VUW 306/5-5 (H-GB)
ecoTEC plus 835| 0010021822| 47-044-82
VUI 286/5-5 (H-GB)
ecoTEC plus 938| 0010021827| 47-044-87
Product description
Product design
- Control elements
- Plate with serial number on the rear
- Front flap
Control elements
- On/off button
- Built-in controller (accessory)
- Fault clearance button
- Operating buttons
- Display
Operator control panel
- Current heating flow temperature, filling pressure of the heating installation, operating mode, fault code or additional information
- Current assignment of the right-hand selection button
- Left- and right-hand selection buttons
- and button
- Maximum output operation (for chimney sweeps only)
- Access to the menu for additional information
- Current assignment of the left-hand selection button
- Active operating status
Displayed symbols
Symbol | Meaning | Explanation |
---|---|---|
Burner operating correctly | Burner on |
**bar
**
| Current filling pressure of the heating system
The dashed lines show the permitted range|
-
Permanently on:
Filling pressure in the permitted range -
Flashing: Filling pressure outside the permitted range
| Hot water generation
active|
- Permanently on: Draw-off mode before burner is on
- Flashing: Burner on in draw-off mode
| Heating mode active|
-
Permanently on:
Heating mode heat requirement -
Flashing: Burner on in heating mode
| Comfort mode active|
- Permanently on: Comfort mode active
- Flashing: Comfort mode active, burner on
| Maintenance required| Information on the maintenance message in the “Live
Monitor”
| Summer mode active
Heating mode is switched off|
| Burner anti-cycling time is active| To avoid the need for frequent switching
on and off (increases the product’s working life).
F.XX
| Fault in the product| Appears instead of the basic display, may be an explanatory plain text display.
Information on the identification plate
The identification plate is mounted on the underside of the product in the factory.
Information on the identification plate | Meaning |
---|---|
Read the instructions. | |
VU… | Vaillant gas-fired wall-hung boiler for heating |
VUW…, VUI… | Vaillant gas-fired wall-hung boiler for heating and hot |
water generation
..6/5-5| Calorific value power/product generation equipment
ecoTEC plus| Product designation
2H, G20 – 20 mbar (2.0 kPa)| Gas group and gas connection pressure as set at
the factory
ww/yyyy| Date of manufacture: Week/year
Cat.| Approved gas boiler category
Types| Approved units of type
PMS| Permissible total overpressure in heating mode
PMW| Permissible total overpressure during hot water generation
Tmax.| Max. flow temperature
ED 92/42| Current efficiency directive fulfilled with 4* rating
V Hz| Mains voltage and mains frequency
W| Max. electrical power consumption
IP| Level of protection
| Heating mode
| Hot water generation
P| Nominal heat output range
Q| Heat input range
D| Nominal hot water draw-off rate
| Bar code with
serial number,
7th to 16th digit = product article number
Serial number
The serial number is located on a plastic plate behind the front flap.
CE label
The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the identification plate.
The declaration of conformity can be viewed at the manufacturer’s site.
Energy Saving Trust Endorsed Products
Only the most energy efficient products can carry the ‘Energy Saving Trust Endorsed Product’ brandmark making it easy for consumers to choose products that have met strict energy performance criteria.
Available for: Boilers, Heating controls and chemical inhibitors, the Energy Saving Trust endorsed product brandmark gives consumers confidence that a product will cost less to run, help lower energy bills and reduce carbon emissions.
About the Energy Saving Trust
Energy Saving Trust is an independent and impartial organisation that provides trusted energy saving advice to empower millions of people to lead affordable, low energy lifestyles. For more information visit energysavingtrust.org.uk
Hot Water Association
Vaillant is a full member of the Hot Water Association and promotes the scheme in association with its cylinder range. Details are available on the web site www.vaillant.co.uk
hot water association
Benchmark
Vaillant is a licensed member of the Benchmark Scheme. Benchmark places
responsibilities on both manufactures and installers.
The purpose is to ensure that customers are provided with the correct
equipment for their needs, that it is installed, commissioned and serviced in
accordance with the manufacturer’s instructions by a competent person approved
at the time by the Health and Safety Executive and that it meets the
requirements of the appropriate Building Regulations.
The Benchmark Checklist can be used to demonstrate compliance with Building
Regulations and should be provided to the customer for future reference.
Installers are required to carry out installation, commissioning and servicing
work in accordance with the Benchmark Code of Practice which is available from
the Heating and Hot water Industry Council who manage and promote the Scheme.
Benchmark is managed and promoted by the Heating and Hot water Industry
Council.
For more information visit
www.centralheating.co.uk
Operation
Operating concept
Operator control element | Function |
---|---|
- Setting the hot water temperature
- Cancelling the activation of an operating mode
- Cancelling a change to a set value
- Going one selection level higher
|
- Setting the heating flow temperature
- Reading the system pressure
- Activating the comfort mode
- Activating the operating mode
- Confirm setting
- Going one selection level lower
+ at the same time|
- Calling up the menu
or |
- Reducing or increasing the set value
- Scrolling through menu entries
The current function of the and buttons is shown on the display.
Adjustable values are always displayed as flashing.
You must always confirm a change to a value. Only then is the new setting saved. You can press ****to cancel an operation at any time.
Basic display
The basic display shows the current condition of the product. If you press a selection button, the activated function is displayed in the display.
The functions that are available depend on whether a controller is connected to the product.
You can switch back to the basic display by:
- Pressing ****to exit the selection levels
- Not pressing any button for longer than 15 minutes.
If there is an error message present, the basic displays switches to the error message.
Menu display
- Scroll bar
- Current assignment of the and buttons.
- Selection level list entries
- Name of the selection level
You can find an overview of the menu structure in the appendix. Operator level – overview (→ Page 13)
Adjustment and display levels
The product has two adjustment and display levels.
The end user level contains information and setting options that you require as the end user.
The installer level is reserved for the competent person. It is protected by a code. Only competent persons may change any settings in the installer level.
Operator level – overview (→ Page 13)
Cabinet-type casing
Enclosing the product in cabinet-type casing requires compliance with the applicable design instructions.
If you require cabinet-type casing for your product, consult a heating specialist company. Never, under any circumstances, enclose the product yourself.
Opening the isolator devices
- Ask the competent person who installed the product to explain to you where these isolator devices are located and how to handle them.
- Open the gas isolator cock fully.
- Open the service valves in the heating installation’s flow and return.
Conditions: Product with integrated hot water generation or connected domestic hot water cylinder
- Open the cold water stop valve.
Starting up the product
- Only start up the product once the casing has been completely closed.
Switching on the product
- press the on/off button (1).
◁ The “Basic display” (→ Page 8) (2) appears on the display.
Setting the language
- Press and hold and **at the same time.**
- Also briefly press .
- Press and hold and **** until the display shows the language setting.
- Select the required language by pressing or .
- Confirm by pressing ****.
- Once you have set the correct language, press **** again to confirm this.
Setting the heating flow temperature
- Press ( ).
◁ The target value of the heating flow temperature appears on the display.
Note
The competent person may have adjusted the maximum possible temperature.
Conditions: No controller connected
- Use or to set the required heating flow temperature.
- Confirm by pressing ****.
Conditions: Controller connected
- Set the maximum possible heating flow temperature on the product.
- Confirm by pressing ****.
- Set the required heating flow temperature on the controller (→ Controller operating instructions).
Setting the hot water temperature
Warning.
Risk of being scalded by hot water.
To protect against Legionella, the hot water can be heated up to above 60 °C at predefined times.
- Have a competent person inform you about the measures that should be taken to protect against Legionella in your system.
- Press ( ).
◁ The set hot water temperature flashes in the display.
Conditions: No controller connected
- Change the hot water temperature by pressing ** o r .**
- Confirm by pressing ****.
Conditions: Controller connected
- Use **** to set the maximum possible hot water temperature on the product.
- Confirm by pressing ****.
- Set the required hot water temperature on the controller (→ Controller operating instructions).
Switching Comfort mode on and off
Note
Comfort mode immediately supplies hot water at the required temperature, without you having to wait for the water to heat up.
-
Press ( ).
-
Press ( ).
◁ Comfort on or Comfort off are shown flashing in the display. -
Activate or deactivate Comfort mode by pressing or respectively.
-
Press to confirm this change.
◁ When you have activated Comfort mode, the “ ” symbol appears on the basic display. When you have deactivated Comfort mode, the “ ****” symbol goes out on the basic display.
Activating the shift-load cylinder
Applicability: Product with integrated hot water generation and shift- load cylinder
To activate an actoSTOR shift-load cylinder which is also connected, you must switch on cylinder charging on your product.
-
To do this, activate Comfort mode (Comfort mode (→ Page 9)).
◁ The symbol “ ****” appears in the display. -
Set the hot water temperature.
Conditions: Cylinder charging switched on
– Hot water temperature: 50 … 65 ℃
Danger!
Risk of scalding!
The products are equipped with an automatic anti-legionella function: If the temperature in the shift-load cylinder falls below 50 °C for 24 hours, the cylinder is heated up to 70 °C once.
▶ Please note when drawing water that it can be very hot. -
If you want to switch off the “Anti-legionella function”, you
should ask a competent person. -
If you want to switch off cylinder charging, deactivate Comfort mode “Switching Comfort mode on and off (→ Page 9)”.
Conditions: Cylinder charging switched off
– Hot water temperature: 35 … 65 ℃
◁ The cylinder is not maintained at a specific temperature. If you draw off the water, the product switches on and, in this case, only operates as an instantaneous water heater.
Setting the target cylinder temperature
Applicability: Product with integrated hot water generation and shift- load cylinder
Conditions: Water hardness: > 3.57 mol/m³
- Have a competent person take appropriate measures to protect against Legionella.
- Set the target cylinder temperature to a maximum of 50 °C.
Switching off the product’s functions
Switching off heating mode (Summer mode)
-
To switch off heating mode without switching off hot water generation, press ( ).
◁ The value of the heating flow temperature appears in the display. -
Use the **button to set the heating flow temperature to Heating off.**
-
Confirm by pressing ****.
◁ Heating mode is switched off.
◁ The symbol appears on the display.
Switching off hot water generation
Applicability: Product with hot water generation through external domestic hot water cylinder
-
To switch off cylinder charging without switching off heating mode, press ( ).
◁ The set hot water temperature flashes in the display. -
Use the ** button to set the hot water temperature to Heating off.**
-
Confirm by pressing ****.
◁ Cylinder charging is switched off.
◁ Only the frost protection function for the cylinder remains active.
Guaranteeing the correct filling pressure of the heating system
Checking the filling pressure of the heating installation
Note
To ensure that the heating installation operates smoothly, the filling
pressure when the heating installation is cold must be between 0.1 MPa and 0.2
MPa (1.0 bar and 2.0 bar) or lie between the two dashed lines in the bar graph
display.
If the heating installation extends over several storeys, a higher filling pressure may be required for the heating installation. Ask a competent person for details.
In addition, the symbol appears after approx. one minute.
If the filling pressure in the heating installation falls below 0.05 MPa (0.5 bar), then the product switches off. The display alternates between the fault message F.22 and the current filling pressure.
-
Press **** twice.
◁ The values for the current filling pressure and for the minimum and maximum filling pressures appear in the display. -
Check the filling pressure in the display.
1 / 2
System pressure: 0.1 … 0.2 MPa (1.0 … 2.0 bar)
The filling pressure is in the intended pressure range.
2 / 2
Filling pressure: < 0.08 MPa (< 0.80 bar)
▶ Fill the heating installation. (→ Page 10)
◁ If you have topped up the installation with sufficient heating water, the display automatically disappears after 20 seconds.
Filling the heating installation
Caution.
Risk of material damage due to heating
water that is extremely calciferous or corrosive or contaminated by
chemicals.
Unsuitable tap water damages the seals and diaphragms, blocks components in the product and heating installation through which the water flows and causes noise.
- Only fill the heating installation with suitable heating water.
- Ask a competent person where the filling cock is located.
- Connect the filling tap to a heating water supply in the way you were told by the competent person.
- Open all radiator valves (thermostatic radiator valves) of the heating installation.
- Open the heating water supply.
- Turn the filling cock on slowly and allow water to flow in until the required filling pressure has been reached.
- Close the heating water supply.
- Purge all radiators.
- Check the filling pressure in the display.
- Top up with more water if necessary.
- Close the filling cock.
- Return to the basic display. (→ Page 8)
Protecting the heating installation against frost
Frost protection function
Caution.
Risk of material damage due to frost.
The frost protection function cannot guarantee flow through the entire heating installation, which means that parts of the heating installation may freeze and therefore become damaged.
- During a period of frost, ensure that the heating installation remains in operation and that all rooms are sufficiently heated, even when you are away.
Note
To keep the frost protection devices active, you should switch your product on and off using the controller, if one is provided.
If the heating flow temperature falls below 5 °C when the on/off button is on, the product comes into operation and heats the circulating water to approx. 30 °C on both the heating side and the hot water side (if available).
Draining the heating installation
You can guarantee frost protection during very long switch off times by draining the heating installation and the product completely.
- Consult a competent person about this.
Troubleshooting
Detecting and rectifying faults
▶ If faults occur, proceed in accordance with the table in the appendix.
Troubleshooting (→ Page 14)
▶ If you have been unable to eliminate the fault using the measures specified,
or fault messages (F.xx) appear, consult a competent person.
Calling up (Live monitor) status codes
▶ Press and at the same time.
Status codes – Overview (→ Page 13)
◁ The current operating status (status code) is shown on the display.
Care and maintenance
Maintenance
An annual inspection of the product carried out by a competent person is a
prerequisite for ensuring that the product is permanently ready and safe for
operation, reliable, and has a long working life.
After servicing, complete the relevant service interval record section of the
benchmark checklist, located at the rear of the installation manual.
Caring for the product
Caution.
Risk of material damage caused by unsuitable cleaning agents.
▶ Do not use sprays, scouring agents, detergents, solvents or cleaning agents
that
contain chlorine.
- Clean the casing with a damp cloth and a little solvent free soap.
Reading maintenance messages
If the symbol is shown on the display, the product requires maintenance work.
The product is not in fault mode but continues to operate.
- Consult a competent person about this.
- If the water pressure is flashing at the same time, simply add more heating water.
Checking the condensate drain pipework and tundish
The condensate drain pipework and tundish must always be penetrable.
- Regularly check the condensate drain pipework and tundish for faults and, particularly, for blockages.
You must not be able to see or feel any obstructions in the condensate drain pipework and tundish.
- If you notice a fault, have it rectified by a competent person.
Decommissioning
Temporarily decommissioning the product
Caution.
Risk of material damage due to frost.
The frost protection and monitoring devices are only active while the unit is connected to the power mains and switched on via the on/off button, and when the gas isolator cock is open.
▶ Temporarily decommission the product only if no frost is expected.
- Temporarily decommission the product only if no frost is expected.
- Press the on/off button. ◁ The display goes out.
- When decommissioning the product for a prolonged period (e.g. holiday), close the gas isolator cock and also, for combination products, the cold water stop valve.
Permanently decommissioning the product
- Have a competent person permanently decommission the product.
Recycling and disposal
-
The competent person who installed your product is responsible for the disposal of the packaging.
If the product is identified with this symbol: -
In this case, do not dispose of the product with the household waste.
-
Instead, hand in the product to a collection centre for old electrical or electronic appliances
If the product contains batteries that are marked with this symbol, these batteries may contain substances that are hazardous to human health and the environment.
▶ In this case, dispose of the batteries at a collection point
for batteries.
Guarantee and customer service
Guarantee
– Two year guarantee for ecoTEC plus appliances
Vaillant provides this appliance with a parts and labour guarantee against defects that may occur within twenty four months of the installation date. For the 2nd year of the guarantee to be valid an annual service must be carried out by a competent person approved at the time by the Health and Safety Executive one year after installation. The cost of this annual service is not included in the guarantee.
– Registering with us
Registration is simple. Just complete the Guarantee Registration Card and return to Vaillant within 30 days of installation. Your details will then be automatically registered within the Vaillant scheme.
– Immediate help
If your Vaillant boiler develops a fault your first action should be to contact your installer, as his professional assessment is needed under the terms of our Guarantee. If you are unable to contact your installer, phone Vaillant Service Solutions:
Telephone: 0330 100 3461
Customer service
To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions for further details:
Telephone: 0330 100 3461
Appendix
A Operator level – overview
Setting level| Values| Unit| Increment, select| Default
setting
---|---|---|---|---
Min.| Max.
Water pressure →
Water pressure| Current value| bar| |
Live monitor →
Status| Current value| | |
Information →
Contact details| Phone number| | |
Serial number| Permanent value| | |
Display contrast| Current value| | 1| 25
15| 40
Basic settings →
Language| Current language| | Languages available for selection|
Country- specific
Resets →
Reset anti-cycl. time| Current value| min| |
B Status codes – Overview
Status codes that are not listed here can be viewed in the installation instructions.
Status code | Parameter | Meaning |
---|
Displays in heating mode
S.00| Heating: No heat demand| Heating: No heat demand
S.02| Heating mode: Pump pre-run| Heating mode: Pump pre-run
S.03| Heating mode: Ignition| Heating mode: Ignition
S.04| Heating mode: Burner on| Heating mode: Burner on
S.06| Heating mode: Fan overrun| Heating mode: Fan overrun
S.07| Heating mode: Pump overrun| Heating mode: Pump overrun
S.08| Heating mode: Anti-cycling time| Heating, remaining anti-
cycling time xx mins
Displays in hot water handling mode
S.10| DHW demand| Hot water requirement via flow sensor
S.14| DHW mode: Burner on| DHW mode: Burner on
Displays in Comfort mode with warm start or hot water handling mode with
cylinder
S.20| DHW demand| Hot water requirement
S.22| DHW mode: Pump pre-run| DHW mode: Pump pre-run
S.24| DHW mode: Burner on| DHW mode: Burner on
Others
S.31| No heat demand: Summer mode| Summer mode active
S.34| Heating mode: Frost protection| Frost protection mode, frost
protection
S.46| Waiting time: Measuring program| Comfort protection mode,
flame loss at minimum load
Troubleshooting
Fault | Cause | Measure |
---|
Product does not start up:
- No hot water
- Heating remains cold
| The gas isolator cock installed on-site and/or the gas isolator cock on the
product is closed.| Open both gas isolator cocks.
The power supply in the building is disconnected.| Check the fuse in the
building. The product switches on automatically when the power is restored.
The product is switched off.| Switch on the product (→ “Switching on the
product” section).
The heating flow temperature is set too low or to the Heating off
position, and/or the hot water temperature is set too low.| Set the heating
flow temperature and hot water temperature (→ “Setting the heating flow
temper- ature” section/→ “Setting the hot water temperat- ure” section).
The system pressure is insufficient.
Low water pressure in the heating installation (fault mes- sage: F.22 ).
| Fill the heating installation (→ “Filling the heating installation”
section).
There is air in the heating installation.| Have your competent person purge
the heating installation.
After three unsuccessful attempts to ignite the flame, the product switches to
fault mode (fault message: F.28 ).| Press the fault clearance key for one
second. The product makes another attempt to ignite the flame.
If you have been unable to eliminate the ignition fault after three fault clearance attempts, consult a competent person.
Hot water generation functioning correctly; heating does not start up.| The external controller is not set correctly.| Set the external controller correctly (→ Controller operating instructions).
0020245033_02
Supplier
Vaillant Ltd.
Nottingham Road Belper Derbyshire DE56 1JT
Telephone 0330 100 3461
info@vaillant.co.uk www.vaillant.co.uk
© These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer’s written consent.
We reserve the right to make technical changes.