Fulham TJTUNV023ACXXXB LED Light Engines Modules Retrofit Kits Owner’s Manual
- June 9, 2024
- FULHAM
Table of Contents
- DirectAC UNV Retrofit Kit Engines
- General Specifications
- Electrical and Optical Specifications
- Thermal Specifications
- Thermal De-Rating: Tc vs. Luminous Flux
- Certification Chart
- Energy Star™ TM-21 Calculator Data
- Compatible Tested Dimmers
- DirectAC Engine Equivalency Chart
- Flicker Test Data Summary
- Battery Backup Option
- Mechanical Drawing
- Wiring Diagram
- Mechanical Drawings
- Color and Binning
- Optical Spectrum
- Guidelines
- Part Number Matrix
- Product Image: 23W DirectAC UNV Round Engine Kit
- Packaging
- Customer Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fulham TJTUNV023ACXXXB LED Light Engines Modules Retrofit Kits
DirectAC UNV Retrofit Kit Engines
- Integrated AC Direct Drive (No DC Driver)
- Universal Voltage (120~277) AC Engine
- Suitable for open or fully enclosed luminaires
- Suitable for luminaires with plastic and glass lenses
- All 90CRI product meets CEC Title 24 requirement
- cULus Classified 1598C
- cULus Recognized 8750
- Energy Star Luminaire 2.1 Listed (for rebate programs)
- Energy Star Luminaire CSD
General Specifications
Input Voltage / Frequency ® | 120-277VAC (+/- 10%) / 50-60Hertz |
---|---|
Input Current® | —0.192A @120V —0.100A @230V —0.083A |
@277V
Input Power ®| 23W (+/- 1W)
Input PF| >0.98
THD| <20%
Operating Frequency per Energy Star @120V/60Hz| 120Hz
Max Lumen Output @ Full Power®| 2159 lumens @ 4000K / 90 CRI
Dimming Type/Range @120V ONLY| Leading Edge (TRIAC) or Trailing Edge (ELV)
/100% — 10%
Beam Angle| 120°
CRI / CCT| 90 / 2700K, 3000K, 3500K, 4000K; 5000K is made to order (MTO)
Operating Temperature Range (ta)| -35 to 50°C / -31°F to 122°F
Maximum Engine Case Temperature (Tc)| L70: Tc max=85°C (185°F) / L90: Tc
max=85°C (185°F)
Maximum Lens Temperature| Lens: 90°C (194°F)
Estimated Lumen Maintenance (at Max Tc)| L70= >54,000 hours / L90= >21,000
hours
Color Consistency| Binning per ANSI C78.377-2015 @85°C; 3 SDCM
Overall Size| 6.97″ diameter x 0.71″ H (177.04mm Dia. x 18.03mm H)
Wire Type/ Length| 18AWG / 12″ Black and White wires
LED Quantity| 64 Pcs.
Weight| 195.5g / 0.43Ibs.
Packaging: Master Carton| 24pcs
Maximum Screw Installation Torque| 60in-lb (960in-ozf)
Safety/Compliance| DirectAC Engines: cURus (File # E486778) TATUNV023AxxxxA
DirectAC Retrofit Kits: cULus (File # E486779) TJTUNV023AxxxxB
RoHS Compliant
Dry and Damp Location
IC Over Temperature Control
Energy Star Luminaire 2.1 Listed°
Energy Star Luminaire CSD 0
CEC JA8-2016
RFI/EMI| FCC Part 15B Consumer, EN55015
Input Surge Test| 2.5kV Common and Differential mode (Per ES Ring Wave Test)
Sound Rating / Noise| A / <24 dBA
Percent Flicker / Flicker Index| <25%/ <0.0706
Protective Lens/Enclosure| High Voltage Barrier / 2.5mm Clear Polycarbonate
5VA Flame rated
Lens Transmittance| >92.5%
PCB Material| MCPCB
Warranty| 5 years @85°C (185°F) Tc from the date of manufacture
Electrolytic Capacitor Rating| _ >60,000 hours
- See page #4 “Certification Chart” for exact models.
- Measured electrical data per UL file
Electrical and Optical Specifications
Color Temperature| DirectAC Engine Part Number| Input Power|
Nominal Luminous Flux @ 90 CRI| Engine Efficacy @ 90 CRI
---|---|---|---|---
2700K| TJTUNV023AC927B| 23W| 1981 lumens| 86 lm/W
3000K| TJTUNV023AC930B| 23W| 2057 lumens| 89 lm/W
3500K| TJTUNV023AC935B| 23W| 2083 lumens| 91 lm/W
4000K| TJTUNV023AC940B| 23W| 2159 lumens| 94 lm/W
5000K| TJTUNV023AC950B| 23W| 2210 lumens| 96 lm/W
NOTES:
- Nominal luminous flux includes a 7.5% loss due to lens. Use a 1.075 multiplier when lens is removed.
- Electrical and optical specifications are based on Tc mod = 25ºC @120V. Reference Amb. Temp. vs Rel. Lum. Flux for other temperatures.
- Specifications are subject to change without notice.
- Meets CEC Title 24 requirement.
- ~10% lumen depreciation @277V input.
Thermal Specifications
DirectAC Engine Retrofit Kit (B)
Storage Temperature Range | -40°C (-40°F) to 80°C (176°F) |
---|---|
Operating Ambient Temperature Range (ta) | -35°C (-31°F) to 50°C (122°F) |
Maximum Engine Case Temperature (Tc) | L70: Tc max=85°C (185°F)/ L90: Tc |
max=85°C (185°F)
Maximum Lens Temperature| 90°C (194°F)
Thermal De-Rating: Tc vs. Luminous Flux
Module Case Temperature (Tc) | Luminous Flux Multiplier |
---|---|
25ºC | 1.000 |
30ºC | 0.988 |
35ºC | 0.975 |
40ºC | 0.963 |
45ºC | 0.951 |
50ºC | 0.938 |
55ºC | 0.926 |
60ºC | 0.914 |
65ºC | 0.901 |
70ºC | 0.889 |
75ºC | 0.877 |
80ºC | 0.864 |
85ºC | 0.852 |
90ºC | 0.840 |
95ºC | 0.827 |
100ºC | 0.815 |
NOTES:
- Refer to LED Engine Retrofit Kit Installation Instructions for further detail.
- This LED Engine Kit can retrofit any luminaire with a dimension/volume greater or equal to the minimum dimensions shown below and on the Installation Instructions.
- This LED Engine Kit can be used with luminaires similar to the one illustrated on the Installation Instructions.
Suitable for surface mounted luminaire with minimum dimensions or volume: 8.5” Dia. x 4.75” H or 173.92 cubic inches
Certification Chart
Energy Star™ TM-21 Calculator Data
Tc Module | Reported L70 | Reported L90 |
---|---|---|
50°C | >54,000 Hrs | >54,000 Hrs |
100°C | >54,000 Hrs | 35,000 Hrs |
110°C | >54,000 Hrs | 30,000 Hrs |
Tc Module | Calculated L70 | Calculated L90 |
--- | --- | --- |
50°C | 180,000 Hrs | 55,000 Hrs |
100°C | 116,000 Hrs | 35,000 Hrs |
110°C | 99,000 Hrs | 30,000 Hrs |
Compatible Tested Dimmers
(Contact Fulham for other alternatives)
(TRIAC or ELV Dimmers)
Manufacture | Model | Type |
---|---|---|
Core | SI061BR-PTA | TRIAC (Leading Edge) Incandescent Analog |
Legrand | ADTP703TUM4 | Universal |
Legrand | RH703PTC | TRIAC (Leading Edge) Incandescent Analog |
Legrand | RH703PTUTC | TRIAC (Leading Edge) Incandescent Analog |
Leviton
| ****
002-6633-PLW
| TRIAC (Leading Edge) Incandescent Analog
Leviton| DDE06-BLZ| ELV (Trailing Edge)
Leviton
| ****
IPL06-10Z
| TRIAC (Leading Edge)
Leviton| R62-6674-P0W| CFL / LED
Leviton| R70-6631-1LW| TRIAC (Leading Edge) Incandescent Analog
Leviton| RDL06-10Z| TRIAC (Leading Edge)
Lutron| CT-600P| TRIAC (Leading Edge)
Lutron| DV-600P| TRIAC (Leading Edge)
Lutron| LG-600P| TRIAC (Leading Edge)
Lutron| NTLV-600| TRIAC (Leading Edge)
Lutron| D-600R| TRIAC (Leading Edge) Incandescent Analog
Lutron| SELV-303P| ELV (Trailing Edge)
Lutron| S-600| TRIAC (Leading Edge)
Lutron| S-603P| TRIAC (Leading Edge) Incandescent Analog
DirectAC Engine Equivalency Chart
DirectAC Engine/Kit (23W) | CFL |
---|---|
Engine/Kit Part Number | System Wattage |
Efficacy | CFL Style |
Wattage** | Lumen Output |
TJTUNV023AC9xxB | 23W |
2 | 39W 36W |
2150 lm
| 59 lm/W
Triple| 13W| 3| 39W| 2535 lm| 59 lm/W
18W| 2| 36W| 2040 lm| 56 lm/W
32W| 1| 32W| 2040 lm| 63 lm/W
42W| 1| 42W| 2720 lm| 64 lm/W
Circline T9| ****
32W
| ****
1
| ****
32W
| ****
1500 lm
| ****
46 lm/W
40W| 1| 40W| 1975 lm| 49 lm/W
NOTES:
- For reference only, several factors apply.
- Emergency systems are not UL classified for field installation.
Flicker Test Data Summary
(Test performed by third party lab using, Lutron S-600P dimmer)
With Dimmer at 100%
100% Light Output Percent Amplitude Modulation
No Filter| 40 Hz| 90 Hz| 200 Hz| 400 Hz| 1000 Hz
24.65%| 0.29%| 1.78%| 23.07%| 23.76%| 23.92%
Measurement Period:| 2.000 sec| Noise:| 20.4 dBA
Recording Interval:| 4.00E-05| Fraction of rated light output:| 100%
Flicker Index:| 0.0706|
With Dimmer at 20%
20% Light Output Percent Amplitude Modulation
No Filter| 40 Hz| 90 Hz| 200 Hz| 400 Hz| 1000 Hz
24.17%| 0.92%| 2.65%| 17.35%| 21.53%| 23.08%
Measurement Period:| 2.000 sec| Noise:| 19.9 dBA
Recording Interval:| 4.00E-05 sec| Fraction of rated light output:| 19%
Flicker Index:| 0.0571|
With Dimmer at Minimum Light Output
Minimum Light Output Percent Amplitude Modulation
No Filter| 40 Hz| 90 Hz| 200 Hz| 400 Hz| 1000 Hz
20.18%| 0.80%| 1.65%| 13.20%| 16.88%| 17.58%
Measurement Period:| 2.000 sec| Noise:| 20.5 dBA
Recording Interval:| 4.00E-05 sec| Fraction of rated light output:| 9%
Flicker Index:| 0.0411|
Battery Backup Option
- FHSCP-UNV-6W-L-SD: Emergency LED Driver for Direct AC Engines
Mechanical Drawing
Overall Dimensions
Length| 9.49″ (241.2mm)
Width| 2.43″ (61.9mm)
Height| 1.49″ (37.9mm)
Wiring Diagram
Specification Sheet:
Mechanical Drawings
(Scale 13 : 20)
Exploded View
Overall Dimensions
Diameter| 6.97” [177.04mm]
Height| 0.71” [18.03mm]
Wire Length
AC Input (Black / White)
| 12” [304.8mm]
Top View
**Side View
**
Color and Binning
Optical Spectrum
NOTES:
- The Color and Binning and Optical Spectrum charts are for reference only. For more detailed info, contact factory.
- Binning per ANSI C78.377-2015 @ 85°C; 3 SDCM.
- The Optical Spectrum values vary depending on product type and color rank.
Guidelines
Reduced Flicker Operation Feature
- DirectAC Engine models have added circuitry to help reduce the Flicker when operated on the 50/60Hz power lines.
The Flicker percentage on these models is below 30% when operated at line voltage, per CEC requirement.
Dimming by line voltage devices may increase the Flicker percentage as the power levels are reduced.
Hi-Pot Testing (Caution)
- All DirectAC Engine models are Hi-Pot tested on the Fulham production line. We advise NOT to apply AC high voltage Dielectric test to LED products as this may damage the sensitive electronic components as well as the LEDs. Please inspect the connection wires for any nicks or cuts in the insulation during and after installation.
Termination Notes
- A luminaire disconnect UL listed connector is included, as part of Fulham’s retrofit kit only, to meet Energy Star requirements.
- Use solid wire size 18AWG/12” per pole, rated at max 600V load and 105°C operating temperature.
- Strip wires to 11-13mm (0.47in.).
- Connector not for multiple use.
For additional information on Wago’s 873 Series Lumi-Nuts® and IDEAL’s 102X
connector, please visit:
http://www.wago.com/infomaterial/wago_ebook/51261593/flipviewerxpress.html
https://idealind.com/shop/30-102x.html
Environmental Rating
- DirectAC Engines are rated for dry and damp locations.
IC Over Temperature Control
- DirectAC Engine models have built in Thermal management, if the unit experiences higher than normal ambient temperatures the circuit by design will reduce the drive current to the LED there by reducing the thermal impact on the LED’s.
Fastening to Luminaire
-
When installing this LED Engine use screws with a diameter less than 0.13in. [3.4mm]. The LED Engine must be mounted on a flat surface and all mounting holes must be used to ensure good contact between the back side of the LED Engine and the mounting surface. Refer to max specified torque for installation. Suggested screw sizes: #5 or M3 Pan Head screw.
Fulham provides four 6-20 X 5/8” Flat Head Self Drilling Screws, see instruction sheets for further details -
During installation process do not remove plastic film backing.
Electrostatic Sensitive Product (ESD)
- Fulham LED products should be handled with proper measures to protect against any potential ESD damage.
- When servicing, personnel should be ground and direct contact with LED should be avoided.
Thermal Management
- Proper thermal management should be employed to ensure life and reliability of product.
Wiring
- Intended for 120~277V application ONLY.
- Connect the Black wire from the DirectAC Engine to the building/source Line by using the proper connectors or wire nuts.
- Connect the White wire from the DirectAC Engine to the building/source Neutral by using the proper connectors or wire nuts.
- DirectAC Engine does not need grounding, but the luminaire must be grounded.
- Intended to be wired on dedicated lighting branch circuit.
- Do not wire on same branch circuit as motors, inductive type loads or heavy machinery which may introduce spikes, noise and other abnormalities onto the Line. Doing so may result in damage to the unit or abnormal lighting conditions.
Part Number Matrix
NOTES:
- DirectAC Engines standard model “B” comes with engine and lens.
- Specifications are subject to change without notice.
- All 90CRI product meets CEC Title 24 requirement
- Standard Product offering. (90CRI / 5000K option is made to order with MOQ and lead time.)
- LED Engine Retrofit Kit includes mounting hardware, retrofit labels, and installation instructions.
Product Image: 23W DirectAC UNV Round Engine Kit
TJTUNV023AC9xxB
WARNING: Risk of fire and electrical shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.
WARNING: Cancer and Reproductive Harm.
www.P65warnings.ca.gov
DirectAC UNV Retrofit Kit Engines:
Hardware, Quick disconnect, Labels & Installation Instructions
Packaging
Master Carton
Twenty-Four (24) Individual DirectAC LED Engine bags inside each Master Carton.
OUTER DIMENSION
L| W| H
16.92”(430mm)| 16.92”(430mm)| 8.07”(205mm)
Net Weight| Gross Weight| QUANTITY
11.02 lbs. (5.00kg)| 13.22 lbs. (6.00kg)| 24pcs.
Customer Service
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.
Specifications subject to change without notice.
order@fulham.com
www.fulham.com
References
- Fulham: Lighting Solutions | LED Drivers | Ballasts | Emergency | Modules
- 51261593
- IDEAL Electrical - Wire Connectors & Hand Tool Kits for the Professional Electrician
- ENERGY STAR Certified Light Fixtures | EPA ENERGY STAR
- The Certified Lighting Subcomponent Database (CSD) | ENERGY STAR
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>