Acuity Brands EVO4 Downlight Round Shower Instruction Manual

June 10, 2024
Acuity Brands

Acuity Brands EVO4 Downlight Round Shower

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE

INSTRUCTIONS AND DEL.IVER TO OWNER AFTER INSTALLATION
  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and Instructions lnduded with and on 1he fixture box and all fixture labels.
  • Before Installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of lumlnaires should be performed by a qualified licensed electrician.
  • Maintenance of the lumlnalres should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the retractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Retractor/lens should be washed In a solution of warm water and any mild, non-abrasive household detergent. rinsed with clean water and wiped dry. Should optical assembly become dirty on the Inside, wipe retractor/lens and clean in above manner, replacing damaged gaskets as necessary.

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

WARNING RISK OF BURN

  • Allow lamp fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and resections for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all limes when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while It is on.

CAUTION RISK OF FIRE

  • Keep combustible and other materials that can bum, away from lamp/lens.
  • Do not operate In close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures In a manner that can cut the outer jacket or damage wire insulation.
  • Never connect an LED product to an unapproved dimmer pack. Contact ABL directly for any dimmers not specifically recommended for the product
  • Unless individual product specifications deem otherwise: Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Maximum ambient temperature is 90°C. Do not operate fixture at temperatures higher than this.
  • Unless individual product specifications deem otherwise: Never mount in places where fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all Installation or servicing of the unit
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • There are no user serviceable parts inside the unit. Do not rewire, reconfigure, or modify the unit or attempt any repairs yourself. Additionally, field replacement of the LED assembly or lamps is not allowed by UL standards at this time. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative.

All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with one of the following Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful I interference
  2. This device must accept any interference received, including interference that may cause undesired operation.

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be Installed near maritime safety communications equipment or other centrical  navigation or communications equipment operating between 0.45-30MHz.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acultybrands.com.

OUR BRANDS

Acuity Controls I American Electric Lighting I Antique Street Lamps I Arancini
D1stech Controls I eloped I Gotham I Healthcare L1ght1ng I Halothane I Hydrail Juno Lighting Group I Lithonia Lighting I Mark Architectural Lighting I Peerless RELOC Wiring I Sunopt1cs I Winona

NSTALLATION INSTRUCTIONS EVO, EVO LW

Mounting Frame

Upon receipt, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier.
Compare the catalog description listed on the packing slip with the label on the carton to ensure you have received the correct merchandise.
Mounting Frame

IMPORTANT SAFETY INFORMATION
For Your Protection, Read Carefully

Warning: Risk of fire. Do not install insulation within 3 inches of fixture sides or wiring compartment, nor above fixture in such a manner as to entrap heat.

Electric current can cause painful shock or serious injury unless handled properly. For your safety, always remember the following:

  • Turn off the supply power.
  • Ground the fixture to avoid potential electrical shocks.
  • Do not handle an energized fixture or energize any fixture with wet hands, when standing on a wet or damp surface, or in water

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

SAVE THESE INSTRUCTIONS

New Installation

Lay-in panel T-bar ceilings:

  1. Cut ceiling opening slightly larger than the outside diameter on the mounting frame. NOTE: For use with flangeless trims, please refer to trim instructions prior to housing installation. For flangeless installation, cut ceiling opening slightly larger than the outside of the vertical wall of the injection molded mudring. 4” Ceiling opening: 5-1/4” (13.2cm). 6” Ceiling opening: 7-1/4” (18.4cm)

  2. Position mounting frame through opening in ceiling. For EVO LW and EVO WW installations, refer to label located on mounting frame for proper orientation with respect to the wall to be illuminated as shown in Figure 1. Release clamping latch arms and adjust channel bars to the correct spacing between T-bar as shown in Figure 2. Secure channel bars to T-bar by means of wire ties, screws or by bending ends onto T-bar as shown in Figure 3.

  3. Once mounting frame has been secured in structure, adjust the mounting frame vertically to align the bottom edge to either flush or slightly above (1/8” max) the ceiling line as shown in Figure 4. Secure mounting frame into position by closing the clamping latch arm.

  4. If additional security is required, a No. 8 sheet metal screw, wire tie or wire (not supplied) may be used to tie the latch arm to the mounting frame as shown in Figure 2.

  5. Remove knockouts on junction box to feed power supply to fixture as shown in Figure 5. Supply wire must meet applicable electrical codes and be rated for a minimum of 75°C. Junction box is thru-wire rated for 8-No.
    12 AWG conductors (4in-4out). Driver is standard with 0-10V dimming capability with wires provided by others.

  6. Complete necessary splices. Snap the door/driver assembly onto the junction box as shown in Figure 5.

Non-accessible ceiling: (plaster, drywall, etc)

  1. For EVO LW and EVO WW installations, refer to label located on mounting frame for proper orientation with respect to the wall to be illuminated as shown in Figure 1. Release clamping latch arms and adjust channel bars to the correct spacing between joists as shown in Figure 2.

  2. Mounting Channel Bars – Flexible Wiring Method Bend ends of channel bars 90° and mount to joists with vertical adjustment at its lowest point on the mounting frame. Make sure bottom of the flange is flush with the bottom of the joists. Secure mounting frame into position by closing the clamping latch arm. Channel bars will accommodate up to 24” O.C. joists.
    Non-Flexible Wiring Method:

  3. If non-flexible wiring method is used, follow procedure for flexible wiring method. Then lower mounting frame equal to the thickness of the finished ceiling or slightly above as shown in Figure 4.

  4. If additional security is required, a No. 8 sheet metal screw, wire tie or wire (not supplied) may be used to tie the latch arm to the mounting frame as shown in Figure 1.

  5. Remove knockouts on junction box to feed power supply to fixture as shown in Figure 5. Supply wire must meet applicable electrical codes and be rated for a minimum for 75°C.
    Junction box is thru-wire rated for 8-No.
    12 AWG conductors (4in-4out). Driver is standard with 0-10V dimming capability with wires provided by others.

  6. Complete necessary splices. Snap the door/ driver assembly onto the junction box as shown in Figure 5.

For installation of EVO 6 XX/45 and EVO 6 XX/50 luminaires, install with minimum spacings between:

  1. Center-to-center of adjacent luminaires : 61 cm (24 in)
  2. Top of luminaire to overhead building member: 15.2 cm (6 in)
  3. Luminaire center to side building member : 30.5 cm (12 in)

For installation of EVO 4 XX/30 luminaires, install with minimum spacings between:

  1. Center-to-center of adjacent luminaires : 61 cm (24 in)
  2. Top of luminaire to overhead building member: 5.1 cm (2 in)
  3. Luminaire center to side building member : 30.5 cm (12 in)

NOTE: For use with flangeless trims, please refer to trim instructions prior to housing installation.

Emergency Battery equipped luminaires:

  1. Maximum mounting height 15.3 feet to achieve at least 1 foot-candle of illuminance in Emergency mode.
  2. Open emergency battery enclosure by removing the enclosure screws, as shown in Figure 6.
  3. If unit connector present, complete connection after installation and AC power is supplied, as shown in Figure 7. If no connector present, proceed to close the battery enclosure.

NOTE: Products labelled “ILBLP” and “ILBHI” are AC enabled and have no mating connector.

SAVE THESE INSTRUCTIONS

Save These Instructions
Save These Instructions
Save These Instructions
Save These Instructions

GOTHAM ARCHITECTURAL DOWNLIGHTING
P 800 315 4982 F 770 860 3129
www.gothamlighting.com

Documents / Resources

| Acuity Brands EVO4 Downlight Round Shower [pdf] Instruction Manual
EVO4 Downlight Round Shower, EVO4, Downlight Round Shower, Round Shower
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Acuity Brands User Manuals

Related Manuals