Acuity Brands FML4W Low Profile Wide Housing LED Wrap Instruction Manual
- June 10, 2024
- Acuity Brands
Table of Contents
FML4W Low Profile Wide Housing LED Wrap
Product Information
The LED luminaire is a lighting fixture that contains electronic devices that
generate frequencies above 9kHz. The product complies with Part 15 of the FCC
Rules and operates subject to two conditions. The device may not cause harmful
interference, and it must accept any interference received, including
interference that may cause undesired operation. The product comes with
important safety instructions, and failure to follow them could void product
warranties. For a complete listing of product Terms and Conditions, please
visit
www.acuitybrands.com.
The product contains a LED luminaire housing and a LED diffusion lens. It also
comes with a hardware kit that includes wire nuts and Screws. Additional
supplies may be needed depending on the type of ceiling fixture being mounted
to, including drywall or masonry anchors and screws, wood screws, and toggle
bolts.
Product Usage Instructions
-
TURN OFF THE POWER! Before starting the installation process, turn off the power to avoid the risk of electric shock.
-
Remove lens and hardware kit from fixture.
Press in the middle of the lens on one end to lower the lens below the locating feature in the endcap. Slide the lens into the endcap to create a gap between the lens and endcap on the opposite end of the fixture. Use the exposed gap to gently reach under the lens and pull it away from the fixture to remove it. Set the lens aside in a location where it will not fall or become damaged. Remove the bag with the hardware kit from inside of the fixture. -
Prepare for fixture mounting. The fixture must be centered over and mounted to the electrical junction box. If additional support is required, mounting locations at ends of fixture are provided. Have someone assist in holding the fixture against the ceiling. With fixture junction box mounting holes lined up with junction box, mark the end mounting locations on the ceiling. Use appropriate hardware for the ceiling type that fixture is being mounted to. Typical installation onto a drywall ceiling will use drywall anchors rated to hold at least 20 lbs.
-
For 2-3/4 electrical box only: Use a screwdriver to knock out covers in housing for additional mounting slots. Pliers may be necessary to bend knockout several times to remove.
-
Partially thread screws (provided with junction box or 2x 8-32×1 screws provided in hardware kit) into the junction box. Leave the head of the screw approximately 1/4 away from the box (do not tighten).
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information
be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product to dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
- Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
REQUIRED TOOLS:
INCLUDED FIXTURE COMPONENTS:
PART | DESCRIPTION | QUANTITY |
---|---|---|
A | LED LUMINAIRE HOUSING | 1 |
B | LED DIFFUSION LENS | 1 |
SUPPLIED HARDWARE KIT COMPONENTS
DESCRIPTION | QUANTITY |
---|---|
WIRE NUT | 3 |
8-32 x 1” SCREW | 2 |
Scan QR code for product page and additional information https://www.acuitybrands.com/products/detail/1098952
ADDITIONAL SUPPLIES MAY BE NEEDED
DEPENDING ON THE TYPE OF CEILING FIXTURE IS BEING MOUNTED TO:
- Drywall or Masonry Anchors and Screws
- Wood Screws
- Toggle Bolts
INSTALLATION
Step One:
TURN OFF THE POWER!
Step Two:
Remove lens and hardware kit from fixture –
Press in middle of lens (A) on one end to lower lens below locating feature in
endcap.
Slide lens into endcap (B) to create gap between lens and endcap on opposite
end of fixture (C)
Use exposed gap to gently reach under lens and pull away from fixture to
remove (D).
Set lens aside in a location where it will not fall or become damaged.
Remove bag with hardware kit from inside of fixture.
Step Three:
Prepare for fixture mounting –
The fixture must be centered over, and mounted to, the electrical junction
box.
If additional support is required, mounting locations at ends of fixture are
provided.
Have someone assist in holding the fixture against the ceiling.
With fixture junction box mounting holes lined up with junction box, mark the
end mounting locations on the ceiling.
Use appropriate hardware for the ceiling type that fixture is being mounted
to.
Typical installation onto a drywall ceiling will use drywall anchors rated to
hold at least 20 lbs.
For 2-3/4” electrical box only:
Use screwdriver to knock out covers in housing for additional mounting slots.
Pliers may be necessary to bend knockout several times to remove. For all installs – partially thread screws (provided with junction
box or 2x 8-32×1” screws provided in hardware kit) into junction box. Leave
head of screw approximately 1/4″ away from box (do not tighten).
Step Four:
Make electrical connections in junction box –
DO NOT MAKE CONNECTIONS IN FIXTURE
Connect the hot and neutral (black and white) wires from the junction box to the corresponding wire colors from the fixture, using the provided wire nuts.
Also, connect the ground wire (green) from the fixture to the circuit ground using a wire nut.
Step Five:
Attach fixture to junction box –
Position wires and connections up into junction box.
Lift fixture up and align larger opening of keyhole with heads of partially
threaded screws from Step Three. Rotate fixture clockwise and tighten screws
to secure housing to junction box.
Use appropriate fasteners at ends of fixture if required.
Step Six:
Reassemble lens to housing –
Start with lens parallel to fixture as shown below. With the end of lens 3-4
inches away from the endcap. Support middle of lens up against fixture with
one hand.
– Begin at the end of fixture with lens-endcap gap, place lens groove around
flange of housing (A).
Apply pressure to keep this edge pressed against flange.
- Next, flex first 1-2 feet of the other long edge of lens under flange and inside the housing (B). Lens can withstand significant bending without breaking.
- Then, pull gently on lens (C) to clip lens groove around flange of housing (D). If lens pops out, please repeat this step from the beginning.
- Finally; slide lens towards, and under, endcap (E).
This should seat the lens groove around the housing flange down the length of the lens.
Adjust any un-seated sections of lens groove to housing along the length of the fixture on both sides of lens. Center lens under endcaps so that no gaps exist.
Scan QR code for lens installation video http://lithonia.com/FML4Winstall
DIFFUSION LENS CLEANING:
Use a soft cloth and water to clean the lens. Avoid strong chemicals.
Mild soap or detergent combined with water may also be used, be sure to fully
rinse lens with clean water. Allow lens to air dry before reinstalling.
120V Dimmable:
Compatible with most dimming wall switches that work with LED dimmable
drivers.
Follow installation and use instructions that are provided with the dimming
wall switch.
These wall switches provide dimming control by using the hot and neutral circuit conductors that power the fixture. No additional wiring is required.
PLEASE RETAIN THESE INSTRUCTIONS !
Documents / Resources
|
Acuity Brands FML4W Low Profile Wide Housing LED
Wrap
[pdf] Instruction Manual
FML4W Low Profile Wide Housing LED Wrap, FML4W, Low Profile Wide Housing LED
Wrap, Wide Housing LED Wrap, Housing LED Wrap, LED Wrap, Wrap
---|---
References
- YouTube
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>