OSEF100-Z1H Ventilation Zone 1 Extractor Fan
User Manual
PLEASE READ THE USER’S MANUAL CAREFULLY PRIOR TO INSTALLING, CONNECTION TO
POWER MAINS AND OPERATING THE UNIT.
**** THE MANUFACTURING COMPANY SHALL NOT BE RESPONSIBLE FOR DAMAGE TO HEALTH
AND PROPERTY OF THE CUSTOMER CAUSED BY THE CUSTOMER’S VIOLATING THE USER’S
MANUAL.
FOLLOW THE USER’S MANUAL REQUIREMENTS TO ENSURE DURABLE OPERATION OF THE UNIT,
ITS MECHANICAL AND ELECTRICAL RELIABILITY. KEEP THIS USER’S MANUAL.
SAFETY REQUIREMENTS
All user’s manual requirements as well as the provisions of all the applicable
local and national construction, electrical, and technical norms and standards
must be observed when installing and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing,
maintenance, and repair operations.
Only qualified electricians with a work permit for electrical units up to 1000
V are allowed for installation. The present user’s manual should be carefully
read before beginning works.
Check the unit for any visible damage of the impeller, the casing, and the
grille before starting installation. The casing internals must be free of any
foreign objects that can damage the impeller blades.
While mounting the unit, avoid compression of the casing! Deformation of the
casing may result in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky
substances, or fibrous materials.
Do not use the unit in a hazardous or explosive environment containing
spirits, gasoline, insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the
efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the
document’s preparation.
The Company reserves the right to modify the technical characteristics,
design, or configuration of its products at any time in order to incorporate
the latest technological developments. Never touch the unit with wet or damp
hands.
Never touch the unit when barefoot.
This unit is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
Precautions must be taken to avoid the back-flow of gases into the room from
the open flue of gas or other fuel-burning appliances. Connection to the mains
must be made through a disconnecting device, which is integrated into the
fixed wiring system in accordance with the wiring rules for design of
electrical units, and has a contact separation in all poles that allows for
full disconnection under overvoltage category III conditions.
Ensure that the unit is switched off from the supply mains before removing the
guard.
** THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
DELIVERY SET
Fan — 1 pc.
Screws and dowels — 4 pcs.
Plastic screwdriver (only for models with a timer) — 1 pc.
User’s manual — 1 pc.
Packing box — 1 pc.
Sealing gasket — 1 pc.
BRIEF DESCRIPTION
The product is an axial fan for exhaust ventilation of small and medium-sized
premises. The fan is designed for connection to ø 100 mm air ducts.
OPERATION GUIDELINES
The fan is rated for connection to single-phase AC power mains.
Power supply parameters are stated on the unit packaging and/or the label on
the unit casing. Ingress protection rating against access to hazardous parts
and water ingress is IP45, for fans with a IR option – IP42.
WARNING! The IP rating is indicated for an assembled unit.
The fan is rated for operation at ambient temperatures ranging from +1 °C to
+40 °C.
WARNING! Do not operate the fan outside the specified temperature range.
The unit is rated as a Class II (220-240 V, 50 Hz) electrical appliance and
requires no grounding.
DESIGNATION KEY**
INSTALLATION
The fan is designed for wall or ceiling mounting with direct air discharge to
the ventilation shaft or into the round air duct of matching diameter (Fig.
2). Fan installation with direct air discharge upwards is not allowed (Fig.
2). Fan installation sequence:
Step 1. Cut off power supply and make sure electricity has been turned
off (Fig. 3).
Step 2. Run the power cable to the vent hole (Fig. 4).
Step 3. Remove the front panel from the fan. Then remove the circuit
board cover (Fig. 5).
Step 4. Mark and drill holes for mounting the fan, fasten the sealing
gasket, and then install the fan (Fig. 6-8).
Step 5. Connect the fan to power mains according to the wiring diagram
(Fig. 12-15).
Step 6. Install the circuit board cover (Fig. 9) and the front panel on
the fan casing (Fig. 10).
Step 7. Supply power voltage to the fan (Fig. 11).
TERMINAL DESIGNATIONS ON WIRING DIAGRAMS
L: phase
N: neutral
S: external switch
FAN OPERATION SETUP
**** THE TIMER CIRCUIT IS LIVE. MAKE SURE THE FAN IS DISCONNECTED FROM POWER SUPPLY.
— interval timer turning on and adjustment is performed with the potentiometer
Ti. To turn the interval timer off, set the potentiometer Ti into the leftmost
position. Rotation of the potentiometer for 1/3 clockwise sets the interval
timer operation for 6 hours, rotation of the potentiometer for 2/3 clockwise
sets the interval timer operation for 12 hours, and rotation of the
potentiometer clockwise in the rightmost position sets the interval timer
operation for 24 hours.
— To adjust the fan turn-on delay time, turn the control knob Ton clockwise to
increase and counter-clockwise to decrease the turn-on delay time
respectively, adjustable from 0 up to 2 minutes.
off — To adjust the fan turn-off delay time, turn the control knob Toff
clockwise to increase and counter-clockwise to decrease the turn-off delay
time respectively, adjustable from 2 up to 30 minutes.
— To adjust the humidity set point, turn the control knob H clockwise to
increase and counter-clockwise to decrease the humidity sensor set point,
adjustable from 60 % up to 90 %.
The fan delivery set includes a specially designed plastic screwdriver for fan
settings adjustments. Use it to change the turron and turn-off delay time and
the humidity set point.
DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT OPERATIONS NOT TO
DAMAGE THE CIRCUIT BOARD.
TECHNICAL MAINTENANCE
The fan maintenance periodicity is at least once per 6 months.
Maintenance steps:
- Disconnect the fan from power supply and make sure electricity has been turned off (Fig. 16).
- Remove the front panel, wipe the fan with a dry cloth or a brush (Fig. 17).
- Clean the front panel under running water (Fig. 18).
- Wipe the fan surfaces dry.
- Cover the fan with the front panel.
- Connect power supply to the fan (Fig. 19).
WARNING! Do not allow water or liquid come into contact with electric components!
TROUBLESHOOTING
Problem | Possible reasons | Troubleshooting |
---|
When the unit is connected to power
mains, the fan does not rotate and does not respond to any controls.| No power
supply.| Make sure the power supply line is connected correctly, otherwise
troubleshoot a connection error.
Internal connection fault.| Contact the Seller.
Low air flow.| The ventilation system is clogged.| Clean the ventilation
system.
Increased noise, vibration.| The impeller is clogged.| Clean the impeller.
The fan is not secured well or is not mounted properly.| Troubleshoot the
installation error.
| The ventilation system is clogged.| Clean the ventilation system.
STORAGE AND TRANSPORTATION REGULATIONS
- Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to + 40 °C and relative humidity up to 70 %.
- Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
- Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
- Follow the handling requirements applicable for the particular type of cargo.
- The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage. The unit must be transported only in the working position.
- Avoid sharp blows, scratches, or rough handling during loading and unloading.
- Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at least 3-4 hours.
MANUFACTURER’S WARRANTY
The product is in compliance with EU norms and standards on low voltage
guidelines and electromagnetic compatibility. We hereby declare that the
product complies with the provisions of Electromagnetic Compatibility (EMC)
Directive 2014/30/ EU of the European Parliament and of the Council, Low
Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the
Council and CE-marking Council Directive 93/68/EEC. This certificate is issued
following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 60 months
after the retail sale date provided the user’s observance of the
transportation, storage, installation, and operation regulations. Should any
malfunctions occur in the course of the unit operation through the
Manufacturer’s fault during the guaranteed period of operation, the user is
entitled to get all the faults eliminated by the manufacturer by means of
warranty repair at the factory free of charge. The warranty repair includes
work specific to elimination of faults in the unit operation to ensure its
intended use by the user within the guaranteed period of operation. The faults
are eliminated by means of replacement or repair of the unit components or a
specific part of such unit component.
The warranty repair does not include:
- outline technical maintenance
- unit installation/dismantling
- unit setup
To benefit from warranty repair, the user must provide the unit, the user’s
manual with the purchase date stamp, and the payment paperwork certifying the
purchase. The unit model must comply with the one stated in the user’s manual.
Contact the Seller for warranty service.
The manufacturer’s warranty does not apply to the following cases:
- User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts previously dismounted by the user.
- Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user’s manual.
- User’s failure to ensure timely technical maintenance of the unit.
- External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.
- Redesign or engineering changes to the unit.
- Replacement and use of any assemblies, parts and components not approved by the manufacturer.
- Unit misuse.
- Violation of the unit installation regulations by the user.
- Violation of the unit control regulations by the user.
- Unit connection to power mains with a voltage different from the one stated in the user’s manual.
- Unit breakdown due to voltage surges in power mains.
- Discretionary repair of the unit by the user.
- Unit repair by any persons without the manufacturer’s authorization.
- Expiration of the unit warranty period.
- Violation of the unit transportation regulations by the user.
- Violation of the unit storage regulations by the user.
- Wrongful actions against the unit committed by third parties.
- Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
- Missing seals if provided by the user’s manual.
- Failure to submit the user’s manual with the unit purchase date stamp.
- Missing payment paperwork certifying the unit purchase.
FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND
TROUBLE-FREE OPERATION OF THE UNIT.
USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION
OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE PURCHASE DATE
STAMP.
Quality Inspector’s Stamp………..
Manufacture Date ……….
Sold by (name and stamp of the seller)
Purchase Date…….
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>