ENGO E901RF Wireless Controller User Manual
- June 9, 2024
- ENGO
Table of Contents
- Introduction
- Product Overview
- Receiver
- Before you start (first power on)
- Time settings
- Operation
- First type schedule programming
- Pairing with the E901RX receiver
- Installer settings
- User settings reset
- Clear settings – factory reset
- Cleaning and Maintenance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
E901RF Wireless Controller User Manual
Introduction
Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU.
Safety Information’s
- Before starting installation work and before using the product, read the entire manual.
- The information contained in the instructions is essential for proper functioning.
- To avoid accidents resulting in personal injury and material damage, please follow all safety precautions, specified in this manual.
- The device should not be used by people with limited mental, sensory or mental abilities, without experience, of insufficient knowledge as well as children.
- Do not use an unassembled device (eg without a cover).
- The device may only be opened by a qualified person.
- Keep electrical devices out of the reach of children and ensure that they do not play with it. Children should not be left unattended. If necessary, disconnect the control system for the entire room.
- Do not leave the packaging, cabinet, or any loose parts of the device unattended, as they pose a risk to children.
WARNING!
- Installation must be carried out by a qualified person with appropriate electrical qualifications in accordance with standards and regulations in force in the given country and in the EU.
- Never try to connect the device other than as described in the manual.
- Before assembly, repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live.
- The device may not be exposed to extreme temperatures, strong vibrations or subjected to mechanical shock.
- The device should not be used in unfavorable environmental conditions or in rooms where there is a concentration of flammable gases, fumes or dust.
WARNING!
- There may be additional protection requirements for the entire installation that the installer is responsible for maintaining.
**** Care for the natural environment is of paramount importance to us. The awareness that we manufacture electronic devices obliges us to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the Chief Inspector for Environmental Protection. The crossed out symbol the trash can on the product means that the product must not be disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.
Product Overview
E901RF is a weekly, surface-mounted electronic room thermostat, used for wireless control of heating devices (e.g. gas, oil boilers, heat pumps) or cooling devices. It has the function of creating your own schedules. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. Please read these instructions carefully before using the device for the first time. The thermostat should use 2xAA, 1.5V alkaline batteries. Rechargeable batteries are not allowed.
In the set:
- thermostat transmitter
- thermostat receiver
Product features:
- has 2 types of time schedules
- possibility to choose hysteresis or built-in TPI algorithm
- maximum / minimum temperature limitation
- two relay types (selectable in thermostat settings): NO (normally open) or NC (normally closed)
- has the HEATING / COOLING function
- PIN lock
- has unique transmission codes
- working range up to 60m in open space
- automatically renews the operating signal
Package content
- E901RF thermostat
- E901RX receiver
- Quick Guide
- Thermostat bracket
- Power supply wire and control wire
- 2xAA batteries
- Mounting screws
Proper thermostat location
Please note:
The ideal position to thermostat mounting is about 1,5m under floor level far
from heating or cooling sources. Thermostat can’t be exposed to sunlight or
any extreme conditions like for example draft.
Because of fire and explosion risk there is not allowed to use thermostat in
atmosphere of explosive gases and flammable liquids (eg coal dust). In case if
any of listed dangers occur you have to use additional protection measures –
anti-dust and explosive gases (tight cover) or prevent their formation.
Furthermore, thermostat can’t be used in condensation of water vapor
conditions and be exposed to water action.
Wall mounting
Remove the thermostat cover as shown in the picture. If there are batteries
inside, remove them.| Use a screwdriver to push the plastic tabs in as shown
in the figure until you feel resistance, and tilt the front part of the
housing.
Separate the front part from the back part in the direction shown above.| Then
fix the back cover to the wall using the supplied mounting screws and the
holes provided (see red arrows).
Using the hinges, fold the back and front covers by moving as shown in the
picture above.
Free-standing thermostat
With the bracket attached to the E901RF set, you can use the thermostat anywhere in the house and put it on a table, desk, etc. To use the bracket properly, see the steps below:
Mount the bracket on the back of the thermostat with use of the two designed holes.
Place the thermostat in a comfortable and accessible place (see „Please note” in chapter 2.2 page 5).
Receiver
The thermostat communicates wirelessly with the receiver. The receiver should be supplied with 230VAC, the maximum switching load of the receiver is 16A. Avoid installing the device in places directly exposed to water, moisture and air condensation. The receiver can operate in two different modes – AUTO (automatic) and MANUAL (manual). To select a specific mode, use the switches on the front of the receiver.
Receiver’s switches description
LEFT SWITCH
1 | ON – receiver ON |
---|---|
2 | OFF – receiver OFF |
RIGHT SWITCH
3| MANUAL – Receiver works in manual mode (receiver operation state depends on
the position of the left switch)
---|---
4| AUTO – Receiver works in AUTO mode (according to the thermostat’s commands)
REMEMBER!:
Thermostat (transmitter) will communicate with receiver only when both are
paired together and receiver’s switches are set to ON and AUTO position.
Receiver LED indicators
The status of the receiver is indicated by two LEDs. These are LEDs with the following colors:
- – green (upper one),
- – orange (lower one).
A detailed explanation of the meaning of the LEDs can be found in the table below:
| DESCRIPTION
---|---
The green LED lights up| The receiver is connected to the 230V power supply.
The green LED flashes| The receiver is in the pairing mode (then you must
activate the” SYNC” parameter in the thermostat).
The green LED is off| The receiver is disconnected from the 230V power supply
or the left switch is in the OFF position.
The LED lights up| In automatic mode, the receiver received a heating /
cooling signal from the thermostat.
The receiver was started in manual mode (left switch is set to ON and right
switch is set to MANUAL)
The LED flashes| The receiver was paired but lost communication with the
thermostat due to out of range or low battery in the thermostat. The receiver
starts flashing after 40 minutes of time when it does not receive a signal
from the thermostat.
The LED is off| In automatic mode, the receiver didn’t get a heating / cooling
signal from the thermostat.
The receiver is OFF in manual mode (left switch is set to OFF and right switch
is set to MANUAL).
Connection description
**Legend:
Boiler – Boiler connection***
– Boiler’s contacts for ON/OFF thermostat (according to the boiler’s
instructions)
Pump
Valve actuator
Symbols explanation:
L, N – power supply 230V
COM, NO – voltage-free output
– fuse
– batteries
Before you start (first power on)
The thermostat is powered by two 1.5V AA alkaline batteries. Insert the batteries into the compartment under the front housing, paying attention to their polarity. The thermostat will start up showing the current software version and then go to the main screen.
LCD icon description
1. Program timeline indicator
2. AM/PM
3. Clock
4. Day of the week indicator
5. Settings icon
6. Key lock function
7. Send a signal (pairing)* only E901RF
8. Holiday Mode
9. Low battery indicator| 10. Frost Protection Mode
11. Comfort Mode
12. Economic Mode
13. Cooling status
14. Heating status
15. Temperature unit
16. Room / setpoint temperature
17. Temporary override
18. Program number
---|---
Button description
Button | Function |
---|---|
Change the parameter value down | |
Change the parameter value up | |
D | Set the day of the week |
H | Set the hour |
M | Set the minutes |
Comfort temperature | |
Economic temperature / Holiday mode | |
AUTO mode / Back button | |
Programming schedule / schedule type selection | |
Confirm button | |
•Reset | Factory Reset |
Time settings
Day/time settings are set using the D, H and M buttons. Please see steps below how to set time/day:
Press any button to highlight the display.| Pressing D button set the day.
Pressing H button set the hour.| Pressing M button set the minutes.
Operation
Manual mode
There are two temperature setpoint levels at our disposal. In manual mode
chosen setpoint temperature level is maintained permanently until user changes
operation mode or set a different temperature for each level.
– Comfort Mode – in this mode, the thermostat is to maintain a constant day
temperature. When the temperature is set manually, e.g. 23°C, the thermostat
maintains it until user switches to another operating mode or set a different
temperature, e.g. 21°C.
– Economic Mode – in this mode, the thermostat is to maintain the reduced
(night) temperature. When the temperature is set manually, e.g. 17°C, the
thermostat maintains it until user switches to another mode or set a different
temperature, e.g. 19°C.
Comfort mode
In the comfort temperature mode, the thermostat is to maintain a constant day
temperature. The comfort temperature level is indicated by sun icon.
To set the comfort temperature, see the steps below:
Press any button to highlight the display.| Press button to enter comfort
temperature mode.
The sun icon should be visible on the display.
Using or buttons set new comfort temperature value.| Confirm by button or wait
until the thermostat will approve your choice itself and display the main
screen.
The thermostat will return to the main screen and display the actual room
temperature.
Economic mode
In the economic temperature mode, the thermostat is to maintain a reduced (night) temperature. This is to ensure a more economical operation of the heating system when, for example, you are away from home. The economic temperature level is indicated by the moon icon. To set the economic (night) temperature, see the steps below:
Press any button to highlight the display.| Press button to enter economic
temperature mode.
The moon icon should be visible on the display.
Using or buttons set new economic temperature value.| Confirm by button or
wait until the thermostat will approve your choice itself and display the main
screen.
The thermostat will return to the main screen and display the actual room
temperature.
AUTO mode – two schedule types
– AUTO Mode – In the automatic mode, the thermostat maintains the set temperature according to the schedule selected by the user. You can choose from 2 types of schedule to manage the temperature during the week.
First type schedule
First type schedule mode is represented by timeline – 24 hours of a day. Empty
„boxes” means hours where Economic (Moon) setpoint temperature will be
maintained, black „boxes” means hours where Comfort (Sun) setpoint
temperature will be maintained.
There are three different configurations in a schedule type 1:
- Two different programs (timelines), separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday)
- Individual programs (timelines) for each day of the week
- Same program (timeline) for the whole week
Second type schedule
Schedule type 2 enables the programming of 6 time intervals per day, with
precision up to 10 minutes. Each of the 6 time intervals allows you to set a
different temperature (schedule type 1 is limited to switching between two
setpoint temperatures (SUN/MOON) at full hours time periods).
When creating a schedule type 2, you must define time and temperature setpoint
(thermostat will start to maintain given setpoint temperature from given time
setting). There are three different schedule configurations:
- Two different programs, separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday)
- Individual programs for each day of the week
- Same program for the whole week
Schedule of the second type example
TIME INTERVAL| DAYS OF THE WEEK (1 TO 5) MON-FRI| DAYS OF THE
WEEK (6 TO 7) SAT-SUN
---|---|---
P1| Time 6:00 Temp. setpoint 21 ° C| Time 6:00 Temp. setpoint 18°C
P2| Time 8:00 Temp. setpoint 14°C| Time 8:00 Temp. setpoint 20°C
P3| Time 11:00 Temp. setpoint 21°C| Time 11:00 Temp. setpoint 22°C
P4| Time 13:00 Temp. setpoint 14°C| Time 11:00 Temp. setpoint 22°C
P5| Time 16:00 Temp. setpoint 21°C| Time 16:00 Temp. setpoint 18°C
P6| Time 21:00 Temp. setpoint 14°C| Time 21:00 Temp. setpoint 14°C
Switching between schedules (AUTO Mode) type 1 and 2
Press any button to highlight the display.| Press and hold PROG button for 5
seconds to enter to the schedule type selection.
Using or buttons choose type of schedule.| Confirm by button. Thermostat will
return to the main screen saving chosen type of schedule (timeline will
disappear if schedule type 2 is chosen).
First type schedule programming
Default program settings (1-3)
Within first type schedule mode there are 9 programs available. Programs 0 to 3 are factory-defined programs that cannot be changed. In this chapter you will find detailed information on the built-in factory programs (1-3) in the E901. These are pre-programmed time settings for the comfort and economy temperature that can be assigned to a selected day. To set up the program, see the steps below. The black squares on the timeline indicate the operating time for the comfort temperature mode, while the absence of them – for the economy temperature mode. Under the chart of each program, there is time (hour) when each mode is active. By default, program 1 is set for each day of the week.
Press any button to highlight the display.| Press PROG button to enter the
programming mode.
Select the week period using or buttons.
Confirm by button.| Using or buttons choose program number (0-3).
Confirm by button. The thermostat will proceed to program selection for the
next day/days.
The thermostat will return to the main screen saving the set program.| At the
bottom of the display you can see the time line, i.e.
the program sequence. Comfortable temperature mode (sun) is set from 6 to 8
and from 16 to 23 o’clock.
PLEASE NOTE!
Programs should be set for all days of the week.
Choosing and programming user programs (4-9)
In order to program your own schedule its necessary to choose user program
(4-9), because only user programs are editable. Then we must draw our own
timeline using Sun/Moon buttons. Thermostat will be switching between two
setpoint temperatures (Comfort and Economy) which are represented by Sun and
Moon icons. Switching time is represented by timeline. See steps below how to
programm your own schedule:
Example: below, program 4 will be defined for the MON – FR period with a
comfort temperature from 8:00 to 16:00 and economic from 0:00 to 8:00 and
16:00 to 0:00. Programming starts from 0:00.
Press any button to highlight the display.| Press PROG button to enter the
programming mode.
Select the week period (MON-FR) using or buttons.
Confirm by button.| Using or buttons choose program number 4.
Use the button several times to set the economic temperature until 8:00.| From
8:00 to 16:00 set comfort temperature by pressing several times button.
Then from 16:00 to 0:00 use the button several times to set the economic
temperature.| Confirm by button.
The thermostat will proceed to program selection/editing for the next day/days
period. Repeat steps 4-8. The thermostat will save changes and return to the
main screen.
Please note!
Programs 0, 1, 2, 3 are factory set and cannot be edited.
Programs 4 to 9 are user defined (editable). One program (e.g. program 4) can
be assigned to several days of the week. If this program is edited, the change
affects all days to which given program is assigned to.
Frost Protection program setting
Frost protection mode (program 0) protects heating system against freezing. It is recommended to set this program if you are planning a long winter trip or if you do not heat up for a long time. The thermostat will maintain a constant temperature of 7˚C, thus reducing energy consumption to a minimum.
Press any button to highlight the display.| Press button to enter the
programming mode.
Select the week period using or buttonsConfirm by button.| Using or buttons
choose program number 0.
Confirm by button. The thermostat will proceed to program selection for the
next day / days.
The thermostat will return to the main screen saving the set program.
Snowflake – icon will appear on the display.c
PLEASE NOTE!
In the frost protection mode, the temperature setpoint can’t be changed and it
is maintained constantly at 7°C.
Temporary override mode
When thermostat is running schedule (automatic mode) we can temporarily override it by new setpoint temperature:
Press any button to highlight the display.| Use or buttons to set the
temperature.
Confirm by button.
The display will show the „hand” symbol.| The overwritten temperature is
maintained until the next change forced by schedule.
Then the „hand” symbol will disappear from the display and the thermostat will
return to the automatic mode.
Second type schedule programming
There are three different configurations in a schedule type 1:
- Two different programs (timelines), separate program for working days (Monday to Friday) and separate program for weekends (Saturday to Sunday)
- Individual programs (timelines) for each day of the week
- Same program (timeline) for the whole week
Exemplary schedule setting for working days and weekend:
Press PROG button to enter the programming mode.| Select the week period using
or buttons.
Confirm by button.
Using or buttons set the hour for the time period and then confirm by button.|
Using or buttons set the minutes for the time period
and then confirm by button.
Use or buttons to set temperature setpoint.
Confirm by button. The thermostat will proceed to program selection for the
next time period (a maximum of 6 time periods/switching points can be set).
Temporary override mode
When thermostat is running schedule mode we can temporarily override it by setting new work mode or setpoint temperature:
Press any button to highlight the display.| Using or buttons set temperature
setpoint during
active AUTO mode.
Confirm by button.| The hand icon will be displayed.
The temperature will be maintained until the next change forced by schedule.
Party mode
In the party mode, the user can override schedule with comfort setpoint temperature by defined number of hours. To do this, follow the steps below:
Hold the button for 3 seconds.| Use or buttons to select the number of hours.
Confirm by button.| Comfort setpoint temperature will be maintained for
defined number of hours. After that thermostat will go back to AUTO mode
(schedule).
The maximum duration of party mode is 9 hours. The temperature setpoint does not change during this mode. When party mode is enabled, pressing SUN, MOON or AUTO button twice (or 3 times if backlight is OFF) will disable it and thermostat will go back to appropriate mode.
To cancel active party mode (example):
To cancel the function, press any button to turn on backlight and then press 2 times button.| The thermostat will stop party mode and will return to schedule (Auto mode).
Holiday mode
Holiday mode is a special program temperature setpoint which thermostat will maintain for specified days. During holiday mode thermostat is maintaining frost protection setpoint temperature. To set holiday mode, follow the steps below:
Press any button to highlight the display.| Press and hold button for 3
seconds.
Use or buttons to select duration of the holiday mode (in days).| Confirm by
button.
Use or buttons to set temperature setpoint which thermostat will maintain for
defined number of days.
Confirm by button.| The thermostat is working in holiday mode. Plane icon is
on the display.
TO STOP HOLIDAY MODE:
Key lock function
To LOCK the thermostat keys, follow the steps below:
Press and hold and buttons for 3 seconds.| A lock icon will appear on the
screen.
The buttons on the thermostat have been locked.
To UNLOCK the thermostat keys, follow these steps:
Press and hold and buttons again for 3 seconds.| The lock icon will disappear
from the screen.
The buttons on the thermostat have been unlocked.
The user has the option to set a PIN code, which he will have to enter each time he wants to unlock the buttons of the thermostat. To set a PIN code, go to parameter P12 (please refer to „Installer settings” section).
Pairing with the E901RX receiver
PLEASE NOTE!
E901RF thermostat is already paired with the receiver!
In order to pair the devices correctly, you must first prepare the receiver
for synchronization!
If you want to re-pair the devices with each other, make sure that the receiver is disconnected from the power supply and the switches on it are in the AUTO and ON positions. Then connect the receiver to the power supply and wait for the green diode to glow continuously.| Move the left switch to the OFF position and back to the ON position with a quick motion.| The green LED will start blinking to confirm that the receiver has entered the pairing mode.
Press and hold button for 5 seconds.| Use button to select SYNC parameter.
Confirm by button.| Using or buttons choose YES and start the pairing process
on a new frequency by pressing the button.
The thermostat started to send a signal to find the receiver (the symbol of
the blinking antenna) and started the countdown with the number 10 (min). The
pairing process may take up to 10 minutes.| When the green diode on the
receiver lights up continuously, the devices have been paired on a new
frequency.
The thermostat will display the message „good”, which means that the devices
are successfully paired with each other.| The thermostat will return to the
main screen.
WARNING! If the green diode on the receiver has not stopped blinking after 10 minutes, repeat the pairing process taking into account the distance between devices, obstacles and interference.
Transmission test
It is important to place the receiver and transmitter in places where nothing is interfering with the radio signal. The range of communication between the transmitter and the receiver in an open area is up to 60m. The radio transmission is influenced by many factors that can shorten the working distance, such as thick walls, drywall covered with aluminum foil, metal objects such as cabinets, general radio interference, etc. However, the range is sufficient for most domestic applications. It is recommended that the radio transmission between devices has to be tested before mounting the thermostat to the wall. The test can be performed by changing the set temperature, i.e. by activating or deactivating the heating.
Check that the thermostat is not sending a signal to heat.
Press any button to highlight the display.| Press button to enter comfort
temperature mode.
The sun icon should be visible on the display.
Using or buttons set new comfort temperature value.| Confirm by button or wait
until the thermostat will approve your choice itself and display the main
screen.
The thermostat started sending a heating signal when the screen went blank,
which was signaled by the antenna symbol.
The flame icon will start to animate, which means that the thermostat is
sending a signal to heat.| Check that the orange LED on the receiver is on. If
so, it means that the communication between the devices is correct.
Set the temperature setpoint a few degrees lower than the room temperature by
repeating steps 1 to 5. Wait a few seconds. The flames icon should stop
animating…| …and the orange LED on the receiver should go out.
Please note:
If the orange LED does not turn on / off as indicated by the transmitter
flame icon, try moving the transmitter closer to the receiver and repeat all
steps from the beginning.
If it still doesn’t work, try the pairing process again.
Installer settings
Press and hold button for 5 seconds.| You are in the installer mode.
Use or buttons to move between parameters. Enter the parameter by button. Edit
the parameter using or button. Confirm the new parameter value with the
button.
INSTALLER PARAMETERS:
Port | Function | Value | Description | Default value |
---|---|---|---|---|
P01 | Heating/Cooling mode selection | **** | Cooling | **** |
**** | Heating | |||
P02 | Control method temperature | 1 | SPAN ±0,25°C | 1 |
2 | SPAN ±0,5°C | |||
3 | TPI for Underfloor Heating | |||
4 | TPI for Radiators | |||
5 | TPI for Electrical Heating | |||
P03 | Display temperature resolution | ,5°C | This parameter specifies the | |
accuracy of the displayed (measured) temperature. | 0,5°C |
0,1°C
PC,| Offset temperature| -3.5°C to -F 3.5°C| If the thermostat indicates wrong
temperature,
you can correct it by ± 3.5°C| 0°C
P05| Relay type| NO| Normally Open type of relay| NO
NC| Normally Closed type of relay
P06| Clock format| 24h| 24 hour| 24h
12h| 12 hour
P07| Temperature Scale| °C| Celsius| °C
°F| Fahrenheit
P08| Minimum setpoint| 5°C – 34,5°C| Minimum heating / cooling temperature
that can be set| 5°C
P09| Maximum setpoint| 5,5°C – 35°C| Maximum heating / cooling temperature
that can be set| 35°C
Pax| Function| Value| Description| Default value
---|---|---|---|---
P10| Key sound| NO| Off| YES
YES| On
P11| PIN Code| NO| Disabled| NO
PIN| Enabled
P12| Require a PIN to unlock
the keys every time| NO| Function disabled| NO
YES| Function enabled
CLR| Clear settings factory reset| NO| No action| NO
YES| Factory Reset
*Only for E901RF thermostat
SYNC| Pairing function with
RXRT510 receiver (SYNC)| NO| Pairing disabled| NO
YES| Pairing enabled
User settings reset
There is a small hole to the right of the OK button. This is the reset button. Pressing the reset button will restore the default values in the user settings (i.e. time, schedule).
Please note:
Do not use a pencil to press the reset button as the graphite build-up on the stylus can short-circuit and damage the thermostat. In environments with very strong electrostatic discharge (+/- 8KV), the product may not function as under normal conditions. So the device may need to be reset.
Clear settings – factory reset
To perform factory reset (which will remove all user/installer settings), use the CLR parameter from installer parameters menu. After confirming the parameter, the thermostat will restore the default settings.
Press any button to highlight the display.| Press and hold button for 5 seconds.
Use or buttons to move to CLR parameter.| Confirm the new parameter value with the button.
Cleaning and Maintenance
The E901RF thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or repairs could only be carried out by ENGO Controls or their appointed agents.
Transmitter’s power supply | 2 x AA batteries |
---|---|
Receiver’s power supply | 230V AC 50 Hz |
Rating max | 16 (5) A |
Output signal | NO/COM relay |
Temperature range | 5 – 35°C |
Display temperature accuracy | 0.1°C or 0.5°C |
Control algorithm | TPI or Hysteresis: ±0.25°C and ±0.5°C |
Communication | Wireless, 868Mhz |
Dimension [mm] | transmitter: 150 x 84 x 22 receiver: 96 x 96 x 27 |
Warranty
ENGO Controls warrants this product to be free from any defects in material
or workmanship and to perform as specified for a period of five years from the
date of installation. ENGO Controls reserves the sole responsibility for
breach of this warranty by repairing or replacing the defective product. This
product includes software that matches the distributor’s identification at the
time of sale. The manufacturer / distributor provides a guarantee covering all
functions and specifics of the product in accordance with this marking. The
distributor’s warranty does not cover the correct operation of the functions
and features available as a result of a product software update.
Customer Name:…………..
Customer Address:………………
Post Code:………………..
Tel No: Email:……………………
Company Name: …………….
Tel No:……………. Email:…………………..
Installation Date:………………
Installer Name:………..
Installer Signature:……….
Distributor:
QL CONTROLS Spa oxo. Sp. k.
43-262 Kobellite
4 Rona St.
Ver. 1
Date of issue: II 2022
Power supply: 2xAA batteries
www.engocontrols.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>