Universal dimmer (flush mounted) Instruction Manual
WARNING
Newly produced drivers work in the RFIO² data protocol mode.
These drivers are loaded in the actuators in a different way than before.
Among other things, it eliminates the risk of inadvertently loading another
randomly occurring controller within range.
Drivers can still be switched to so-called compatibility mode, and loaded in a
simpler (older way).
The mode in which the controllers are working is changed and indicated after
8-second pressing of the ‘Prog’ button.
The LED diode under the pushbutton is on when the button is kept pressed;
after 8 seconds it indicates the chosen mode by different flashing intervals.
The mode changes to the inverse mode after each pressing of the button.
RFIO2 mode
= Double flash (flash, flash, gap, flash, flash)
Compatibility mode
= Flash fast (flash, flash, flash, flash, flash)
Update the controller actuators in RFIO² mode
If the controller is used in RFIO² mode, then to update the controller
actuators, it is necessary to switch not only the actuator to the update mode
(according to the instructions for the actuator), but also the controller in
the following way:
- Press the programming button on the controller, converter for more than 1 second and release it.
- The LED diode starts flashing in second intervals. Leave the LED flashing
- activate the programming mode on the actuator by pressing the programming button for more than 1 second. The actuator is also put into the programming mode.
- The desired function can be selected by the respective number of pressing of the control pushbuttons or inputs (of the converter).
- The programming modes on the controller and actuator can be closed by pressing the programming button for less than 1 second. The LEDs stop flashing.
Use a suitable tool (paper clip, screwdriver) to push on the control pin.
The batteries are raised and the programming button is released.| After
removing the control flaps, the programming button is accessible.
---|---
|
The programming button is operated with a suitable thin tool.|
|
Characteristics
-
The universal built-in dimmer is used to regulate light sources:
R – classic lamps.
L – halogen lamps with wound transformer.
C – halogen lamps with electronic transformer.
ESL – dimmable energy-efficient fluorescent lamps.
LED – LED light sources (230V). -
They can be combined with detectors, controllers, iNELS RF Control or system components.
-
The BOX design lets you mount it right in an installation box, a ceiling or light cover.
7 light functions – smooth starting up or running out with time setting 2 sec to 30 min + additional function SWITCH OFF -
Setting of minimum brightness eliminates blinking of LED and ESL light sources
-
Universal dimmer may be controlled by up to 25 channels
-
Control input “S” for connection of the existing wired pushbutton
-
Programming pushbutton on the element can also be used as manual control of the output
-
For the elements marked as iNELS RF Control2 (RFIO2), it is possible to set the function
-
For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
-
Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
-
Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2 ).
Assembly
mounting in an installation box (even under the existing
button / switch)| mounting into a light cover| ceiling mounted
---|---|---
Connection
Screwless terminals
![inELs RFDEL 71B SL Universal Dimmer
- coil transformer](https://manuals.plus/wp-content/uploads/2022/12/inELs- RFDEL-71B-SL-Universal-Dimmer-coil-transformer.png)
Radio frequency signal penetration through various construction materials
For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures
60 – 90 % | 80 – 95 % | 20 – 60 % | 0 – 10 % | 80- 90 % |
---|---|---|---|---|
brick walls | wooden structures with plaster boards | reinforced concrete | metal | |
partitions | common glass |
Indication, manual control
type of source | symbol | description |
---|---|---|
R, Cresistive / capacitive | ordinary light bulb, halogen lamp /electronic |
transformer for low-vol-tage halogen lamps
Linductive| | coiled transformer for low-voltage halogen lamps
- LED STATUS – indication of the device status.
- Manual control is performed by pressing the PROG button for less than 1s.
- Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.
Compatibility
The device can be combined with all system components, controls and devices of
iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication
protocol.
Programming with RF control units
The address listed on the front of the actuator is used for programming and controlling actuators by RF control units.
SETUP mode (load type selection and minimumbrightness setting)
Load type setting and minimum brightness setting
Switching over to the SETUP mode can be carried out by quick fourfold click on
the programming pushbutton. (4x PROG < 1s) The choice of the load type is the
first function of the SETUP mode. In this mode the output brightness changes
automatically between 0% and 100% and the LED on the instrument indicates the
actually chosen load type:
– R, C mode – fourfold flash
– L mode – double flash The mode can be changed to the inverse mode by pressing
the pushbutton on any controller that is already learned. Setting of minimum
brightness is the other function of the SETUP mode.
This function can be chosen by short pressing the PROG pushbutton. This mode
is indicated by the same blinking mode as the learning mode (LED blinking 1x
per second). Minimum brightness can be set using any already learned
controlled. Another short pressing the PROG pushbutton closes the SETUP mode
and the preset type of the load and minimum brightness are saved into memory.
Functions and programming with RF transmitters
Light scene function 1
Description of light scene 1
a) By pressing the programmed button for less than 0.5s, the light
illuminates; it goes out by pressing again.
b) By pressing the programmed button for more than 0.5s, fluid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on /off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button. The actuator remembers the adjusted value even
after disconnecting from the power supply.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is flashing in 1s interval.| A
press of your selected button on the RF transmitter assigns the function light
scene 1.| Press of programming button on actuator RFDEL-71B-SL shorter then 1
second will finish programming mode.
The LED lights up according to the pre-set memory function.
---|---|---
| |
Light scene function 2
Description of light scene 2
a) By pressing the programmed button for less than 3s, the light illuminates;
it goes out by pressing again.
b) In order to limit undesirable control of brightness, fluid brightness
control occurs only by pressing a programmed button for over 3s. After
releasing the button, the brightness level is saved in the memory, and
pressing the button shortly later will switch the light on / off to this
intensity.
c) It is possible to readjust the change in intensity at any time by pressing
the programmed button for over 3s. The actuator remembers the adjusted value
even after disconnecting from the power supply.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is flashing in 1s interval.|
Two presses of your selected button on the RF transmitter assigns the function
light scene 2 (must be a lapse of 1s between individual presses).| Press of
programming button on actuator RFDEL-71B-SL shorter then 1 second will fi nish
programming mode. The LED lights up according to the pre-set memory function.
---|---|---
| |
Light scene function 3
Description of light scene 3
a) By pressing the programmed button for less than 0.5s, the light fluidly
illuminates for a period of 3s (at 100% brightness). By pressing the button
shortly again, the light will continuously switch off for 3 seconds.
b) By pressing the programmed button for more than 0.5s, fl uid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on /off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button. The actuator remembers the adjusted value even
after disconnecting from the power supply.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL intoprogramming mode. LED is flashing in 1s interval.|
Three presses of your selected button on the RF transmitter assigns the
function light scene 3 (must be a lapse of 1s between individual presses).|
Press of programming button on actuator RFDEL-71B-SL shorter then 1 second
will fi nish programming mode. The LED lights up according to the pre-set
memory function.
---|---|---
| |
Light scene function 4
Description of light scene
a) By pressing the programmed button for less than 0.5s, the light
illuminates. By pressing the button shortly again, the light will continuously
switch off for 3 seconds (at 100% brightness).
b) By pressing the programmed button for more than 0.5s, fluid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on/off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button. The actuator remembers the adjusted value even
after disconnecting from the power supply.
Programming
Press of programming but- ton on actuator RFDEL-71BSL for 1 second will
activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s
interval.| Four presses of your selected button on the RF transmitter assigns
the function light scene 4 (must be a lapse of 1s between individual
presses).| Press of programming but- ton on actuator RFDEL-71B-SL shorter then
1 second will fi nish programming mode. The LED lights up according to the pre-
set memory function.
---|---|---
| |
Function sunrise
Description of sunrise function
After pressing the programmed button, the light begins to illuminate in the programmed time interval in a range of 2 seconds to 30 minutes.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.|
Assignment of the sunrise function is performed by fi ve presses of the
selected button on the RF transmitter (must be a lapse of 1s between
individual presses).
---|---
|
Press of programming button longer then 5 seconds, will activate actuator into
timing mode. LED fl ashs 2x in each 1s interval. After releasing the button,
the time of the sunrise function begins to count down (period of complete
illumination of the light).| After the desired time has elapsed, the timing
mode ends by pressing the button on the RF transmitter, to which the sunrise
function is assigned. This stores the set time interval into the actuator
memory.
|
Press of programming button on actuator RFDEL-71B-SL shorter then 1 second
will fi nish programming mode. The LED lights up according to the preset memory
function.|
Function sunset
Description of sunset function
After pressing the programmed button, the light begins to dim in the programmed time interval in a range of 2 seconds to 30 minutes.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.|
Assignment of the sunset function is performed by six presses of the selected
button on the RF transmitter (must be a lapse of 1s between individual
presses).
---|---
|
Press of programming button longer then 5 seconds, will activate actuator into
timing mode. LED fl ashs 2x in each 1s interval. After releasing the button,
the time of the sunset function begins to count down (period of complete
dimming of the light).| After the desired time has elapsed, the timing mode
ends by pressing the button on the RF transmitter, to which the sunset
function is assigned. This stores the set time interval into the actuator
memory.
|
Press of programming button on actuator RFDEL-71B-SL shorter then 1 second
will fi nish programming mode. The LED lights up according to the preset memory
function.|
Function ON/OFF
Description of ON/OFF
If the light is switched off , pressing the programmed button will switch it on. If the light is switched on, pressing the programmed button will switch it off .
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.|
Seven presses of your selected button on the RF transmitter assigns the
function ON/OFF (must be a lapse of 1s between individual presses).| Press of
programming button on actuator RFDEL-71B-SL shorter then 1 second will fi nish
programming mode. The LED lights up according to the pre-set memory function.
---|---|---
| |
Function switch off
Description of switch off
The dimmer output switches off by pressing the button.
Programming
Press of programming button on actuator RFDEL-71BSL for 1 second will activate
actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.|
Eight presses of selected button on the RF transmitter assigns the function
OFF (must be a lapse of 1s between individual presses).| Press of programming
button on actuator RFDEL-71B-SL shorter then 1 second will fi nish programming
mode. The LED lights up according to the pre-set memory function.
---|---|---
| |
Delete actuator
Deleting one position of the transmitter
By pressing the programming button on the actuator for 5 seconds, deletion of one transmitter activates. LED fl ashs 4x in each 1s interval. Pressing the required button on the transmitter deletes it from the actuator’s memory. To confi rm deletion, the LED will confi rm with a fl ash long and the component returns to the operating mode.
Deleting the entire memory
By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED fl ashs 4x in each 1s interval. The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.). You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode.
Control with external button
The function for the external “wired” pushbutton can be assigned in the
same way as for the wireless pushbutton, i.e. by pressing the programming
pushbutton on the actor and respective number of control pushbutton pressings.
Additional information
Do not mix more types of light sources!
Do not try to use energy saving bulbs that are not labeled as dimmable!
Incorrect setting of the type of light source aff ects the extent and dimming
(but no damage to the dimmer or load).
Incorrect setting of the type of load can cause overheating of dimmer.
Maximum number of light sources depends on their internal structure.
Warning
Instruction manual is designated for mounting and also for user of the device.
It is always a part of its packing. Installation and connection can be carried
out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while
observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing
and handling.
In case you notice any sign of damage, deformation, malfunction or missing
part, do not install this device and return it to its seller.
It is necessary to treat this product and its parts as electronic waste after
its lifetime is terminated.
Before starting installation, make sure that all wires, connected parts or
terminals are de-energized.
While mounting and servicing observe safety regulations, norms, directives and
professional, and export regulations for working with electrical devices.
Do not touch parts of the device that are energized –life threat. Due to
transmissivity of RF signal, observe correct location of RF components in a
building where the installation is taking place. RF Control is designated only
for mounting in interiors.
Devices are not designated for installation into exteriors and humid spaces.
The must not be installed into metal switchboards and into plastic
switchboards with metal door – transmissivity of RF signal is then impossible.
RF Control is not recommended for pulleys etc. –radiofrequency signal can be
shielded by an obstruction, interfered, battery of the transceiver can get flat
etc. and thus disable remote control
ELKO EP declares that the RFSG type of equipment complies with Directives
2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU
Declaration of Conformity is at: https://www.elkoep.com/wireless-contact-
converter-230v—rfsg-1m
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211, e-mail: elko@elkoep.com,
www.elkoep.com
Technical parameters
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent power: | 5 VA / cos φ = 0.1 |
Dissipated power: | 0.5 W |
Supply voltage tolerance: | +10/ -15 % |
Connection: | 4 – wire, with NEUTRAL |
Output | |
Dimmed load: | R, L, C, LED, ESL |
Contactless: | 2 x MOSFET |
Load capacity:* | max. 300 W* |
Control | |
Wireless: | up to |
Communication protocol: | RFIO2 |
Frequency: | 866-922 MHz |
Repeater function: | yes |
Range: | až 200 m |
Manual control: | tlačidlo PROG (ON/OFF) |
External button / switch: | yes |
Other data | |
Operating temperature: | -15 až + 45 °C |
Working position: | any /ľubovoľná |
Mounting: | free at lead-in wires |
Protection: | IP40 |
Overvoltage category: | III. |
Contamination degree: | 2 |
Connection: | screwless terminals |
Connecting conductor: | 0.2-1.5 mm2 solid/flexible |
Dimensions: | 43 x 44 x 22 mm |
Weight: | 30 g |
Related standards: | EN 60730, EN 63044, EN 300 220, EN 301 489 |
- loadability of power factor cos φ=1
Power factor of dimmable LED and ESL bulbs moves in following range: cos φ = 0.95 to 0.4.
Aproximate value of maximal load is achieved by multiplication of loadability of dimmer and power factor connected to a light source.
Attention: When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic |
e-mail: elko@elkoep.com | Support: +420 778 427 366
ELKO EP SLOVAKIA, s.r.o. | Fraňa Mojtu 18, 949 01 Nitra | Telefón: +421 37
6586 731 | E-mail: elkoep@elkoep.sk
www.elkoep.com /
www.elkoep.sk
References
- Catalogs and brochures • ELKO EP
- Produkty • ELKO EP s.r.o
- ELKO EP - Výrobca elektronických prístrojov • ELKO EP
- Input contact converter RFSG-1M • ELKO EP
- Katalogy • ELKO EP s.r.o
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>