Your new DuFa watch is a finely tuned timekeeping instrument. It is assembled by hand in Germany and utilises an automatic self-winding movement that has been produced in Japan. These are some of the most accurate, robust automatic movements in the world, and they have been chosen to outfit our timepieces in keeping with our dedication to precision and utter functionality. By using the natural motions of your wrist while the watch is being worn, the rotor in the movement will generate power in the mainspring to run your timepiece to an exacting level of accuracy. Familiarize yourself with the operations of your watch by referring to this booklet. Note: if you do not wear your watch frequently, you may need to manually wind the mainspring until you see the second hand on the dial face start running automatically.
MIYOTA 9100

DUFA MIYOTA 9100 Power Reserve Watch - fig 1

  1. Winding the Mainspring
    In the “A ” position, you may wind the mainspring of the movement by turning the crown clockwise upto 20 times until you see the second hand start to move naturally.

  2. Adjusting the Day
    In the “B ” position, adjust the day by rotating the crown counterclockwise.
    • DO NOT set the Day between 11 pm – 6 am

  3. Adjusting the Date
    In the “B ” position, adjust the date by rotating the crown clockwise.
    • DO NOT set the Date between 9 pm – 1 am

  4. Adjusting the Time
    In the “C ” position, adjust the time by rotating the crown in both directions. Be aware if setting the time in the morning or in the afternoon to adjust it correctly.

  5. Adjusting Month
    ****Push the button “D ” using a sharp object into the divot of the case. Press down to advance the month display and repeat pressing down all the way to keep advancing until
    the correct month is indicated.

  6. Power Reserve Display
    When the mainspring if fully wound, it generates a power reserve for approximately 40+ hours of normal use.
    The power reserve indicator is useful at a glance reference to indicate how much power remains stored in the mainspring. Note that the bar is for reference and actual available power may differ slightly owing to varying conditions of use and environment. As power is used and transferred from the mainspring andno other movements are generated, the power reserve indicator will eventually wind to “O” power. The change in power will also be visible via the change in reading on the Power Reserve Display.

DUFA MIYOTA 9100 Power Reserve Watch - fig 2

WATER RESlSTANCE

The water resistance of a timepiece protects the movement from dust, moisture, and risk of damage to the movement should it be immersed in water. Please see chart for guidelines for recommended exposure of various water ratings. It is important not to attempt to adjust the position of the crown while the timepiece is in contact with water.  ater an enter the case causing damage to the movement. For timepieces with screw-down crowns, it is important to ensure the crown is in the proper position and completely locked before contact with water. For timepieces with chronograph functions, do not engage the chronograph under water, as water may leak in the case and cause damage to the movement.

USE PRECAUTlONS – RESlSTANCE TO WATER
All DuFa timepieces are designed to withstand use as indicated on the following chart.

Indication Water-related Use
Water-resistant characteristics Lightray pers patpiron , light ain, etc.

Bathing,
etc.| Shallow swimming, etc.| Skin diving, (Diving without an oxygen cylinder)
 1
2
3
4| 3 ATM
5 ATM
10 ATM
20 ATM| OK
OK
OK
OK| NO
OK
OK
OK| NO
NO
OK
OK| NO
NO
NO
OK
Always set the crown in the normal position. Tighten the screw-down crown completely.

CARE AND PRECAUTlONS
Each DuFa timepiece is designed and manufactured to exceed the highest of standards. In order to ensure optimal performance and longevity from your timepiece, please eview the simple guidelines for care and precautions of your new DuFa timepiece.

CARE
Your timepiece should be cleaned with a soft cloth and water only. Do not submerge your timepiece. Your timepiece should be rinsed clean and dried with a soft cloth after any saltwater use. In order to maintain the “new look” of metal bracelets, we recommend periodic cleanings of the bracelet. Dip a soft brush in warm soapy water and gently ub bracelet clean. We advise having your timepiece serviced every 18-24 months to ensure long use and trouble free operation.
PRECAUTlONS
While your DuFa timepiece has been designed and built to exacting specification, it is important to avoid the following conditions: extreme heat or cold, as well as prolonged eriods of exposure to direct sunlight, exposure to wet conditions that exceed your timepiece’s water rating (see case back and chart). Never operate any of the function buttons or crown when the timepiece is in contact with water.
Avoid exposure to strong magnetic fields or sources of static electricity as these may interrupt the mechanisms inside the watch. It is also important to avoid extreme shock or impact.

TWO (2) YEAR
lNTERNATlONAL GUARANTEE
Your DuFa watch is guaranteed for a period two (2) years from the original date of purchase under the terms and conditions of the warranty. The DuFa warranty covers aterials  nd manufacturing defects. A copy of the receipt or dealer stamp in the warranty booklet is required for proof of purchase. During the warranty period the watch   movement, hands and dial are the only components covered under this warranty. A covered component will be repaired or the watch will be replaced free of repair charges if it proves to be defective in material or workmanship under normal use.
NOT COVERED BY WARRANTY
– Damage to lens or strap.
– Normal wear and tear.
– Malfunction and deterioration from accident, negligence, or tampering.
– Water damage resulting from improper usage.
– The content of the warranty has been altered.
– There is no presentation of the warranty.

This warranty is void if the watch has been damaged by accident, negligence of persons other than authorized DuFa sales or services agents, unauthorized service, or other  factors not due to defects in materials or workmanship.
REQUESTING WARRANTY AND
OTHER WATCH REPAIR
Should you require work under warranty, please send in your watch, a copy of your sales receipt and/or the warranty booklet with dealer stamp and a description of the problem o the authorized international watch service centre closest to you. For service work that is not covered under this warranty, the service centre may perform the services you request for a charge dependent on the watch style and type of work requested.
These charges are subject to change. For repairs of your DuFa watch, we recommend that you contact an authorized DuFa dealer or the authorized international watch service centre closest to you.
For details, please refer to our website at:
WWW.DEUTSCHE-UHRENFABRIK.DE

DUFA MIYOTA 9100 Power Reserve Watch - QR codehttp://im.dufa-watches.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals