ENGO E901 Programmable Wired Thermostat User Manual

June 9, 2024
ENGO

E901 Programmable Wired Thermostat

E901 | Programmable, wired thermostat
FULL MANUAL

TABLE OF CONTENTS
1. Introduction……………………………………………………………………………………………………………………………………………3 1.1 Product Compliance ………………………………………………………………………………………………………………………………………………….3 1.2 Safety Informations…………………………………………………………………………………………………………………………………………………..3
2. Product Overview …………………………………………………………………………………………………………………………………….4 2.1 Package content……………………………………………………………………………………………………………………………………………………….5 2.2 Proper thermostat location ………………………………………………………………………………………………………………………………………..5 2.3 Wall mounting …………………………………………………………………………………………………………………………………………………………6
3. Connection description ……………………………………………………………………………………………………………………………..7
4. Before you start (first power on) ………………………………………………………………………………………………………………….8 4.1 LCD icon description ………………………………………………………………………………………………………………………………………………….9 4.2 Button description…………………………………………………………………………………………………………………………………………………….9
5. Time settings…………………………………………………………………………………………………………………………………………10
6. Operation……………………………………………………………………………………………………………………………………………..11 6.1 Manual mode …………………………………………………………………………………………………………………………………………………………11 6.1.1 Comfort mode…………………………………………………………………………………………………………………………………………11 6.1.2 Economic mode……………………………………………………………………………………………………………………………………….12 6.2 AUTO mode – schedule type 1……………………………………………………………………………………………………………………………………13 6.2.1 Default program settings (1-3) ………………………………………………………………………………………………………………….13 6.2.2 Choosing and programming (4-9) user programs …………………………………………………………………………………………14 6.2.3 Frost Protection program setting ……………………………………………………………………………………………………………….16 6.2.4 Temporary overwrite mode ………………………………………………………………………………………………………………………17 6.3 AUTO mode – schedule type 2……………………………………………………………………………………………………………………………………18 6.3.1 Switching between AUTO types 1 and 2 ………………………………………………………………………………………………………18 6.3.2 Programming method of the AUTO mode – type 2 ………………………………………………………………………………………..19 6.3.3 Temporary overwrite mode ………………………………………………………………………………………………………………………20 6.4 Party mode…………………………………………………………………………………………………………………………………………………………….21 6.5 Holiday mode …………………………………………………………………………………………………………………………………………………………22
7. Installer settings ……………………………………………………………………………………………………………………………………23
8. User settings reset ………………………………………………………………………………………………………………………………….25
9. Clear settings – factory reset ……………………………………………………………………………………………………………………..25
10. Cleaning and Maintenance ……………………………………………………………………………………………………………………..26
11. Technical Informations …………………………………………………………………………………………………………………………..26
12. Warranty …………………………………………………………………………………………………………………………………………….27

2

E901 FULL USER MANUAL

1. Introduction
1.1 Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU.
1.2 Safety Informations
· Before starting installation work and before using the product, read the entire manual. · The information contained in the instructions is essential for proper functioning. · To avoid accidents resulting in personal injury and material damage, please follow all safety precautions, specified in this manual. · The device should not be used by people with limited mental, sensory or mental abilities, without experience, of insufficient knowledge as well as children. · Do not use an unassembled device (eg without a cover). · The device may only be opened by a qualified person. · Keep electrical devices out of the reach of children and ensure that they do not play with it. Children should not be left unattended. If necessary, disconnect the control system for the entire room. · Do not leave the packaging, cabinet, or any loose parts of the device unattended, as they pose a risk to children.
WARNING! · Installation must be carried out by a qualified person with appropriate electrical qualifications in accordance with standards and regulations in force in the given country and in the EU. · Never try to connect the device other than as described in the manual. · Before assembly, repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live. · The device may not be exposed to extreme temperatures, strong vibrations or subjected to mechanical shock. · The device should not be used in unfavorable environmental conditions or in rooms where there is a concentration of flammable gases, fumes or dust.
WARNING! · There may be additional protection requirements for the entire installation that the installer is responsible for maintaining.

Care for the natural environment is of paramount importance to us. The awareness that we manufacture electronic devices obliges us to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the Chief Inspector for Environmental Protection. The crossed out symbol the trash can on the product means that the product must not be disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.

E901 FULL USER MANUAL

3

2. Product Overview
E901 is a programmable, surface-mounted electronic room thermostat, used for wireless control of heating devices (e.g. gas, oil boilers, heat pumps) or cooling devices. It has the function of creating your own schedules. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. Please read these instructions carefully before using the device for the first time. The thermostat should use AA, 1.5V alkaline batteries. Put the batteries in the battery compartment located under the slide cover. Rechargeable batteries are not allowed.

Product features:

·

has 2 types of time schedules

·

possibility to choose hysteresis or built-in TPI algorithm

·

maximum / minimum temperature limitation

·

two relay types (selectable in thermostat settings): NO (normally open) or NC (normally closed)

·

has the HEATING / COOLING modes

·

PIN lock

4

E901 FULL USER MANUAL

2.1 Package content

  1. E901 thermostat 2) Short instruction 3) 2xAA batteries 4) Mounting screws

1
E901 thermostat
3

2
E901RF | Wireless Programmable Thermostat E901 | Hardwired Programmable Thermostat
Ver. 1 Date of issue: 14 IX 2021 Power supply: 2xAA batteries
Quick Guide
Short manual
4

2.2 Proper thermostat location

2xAA batteries

Mounting screws

Please note:
The ideal position to thermostat mounting is about 1,5m under floor level far from heating or cooling sources. Thermostat can’t be exposed to sunlight or any extreme conditions like for example draft.
Because of fire and explosion risk there is not allowed to use thermostat in atmosphere of explosive gases and flammable liquids (eg coal dust). In case if any of listed dangers occur you have to use additional protection measures ­ anti-dust and explosive gases (tight cover) or prevent their formation. Furthermore, thermostat can’t be used in condensation of water vapor conditions and be exposed to water action.

E901 FULL USER MANUAL

5

2.3 Wall mounting

1

2

Remove the thermostat cover as shown in the picture. If there are batteries inside, remove them.
3

Use a screwdriver to push the plastic tabs in as shown in the figure until you feel resistance,
and tilt the front part of the housing.
4

Separate the front part from the back part in the direction shown above.
5

Then fix the back cover to the wall using the supplied mounting screws and the holes provided (see bigger arrows). Connect the wires to the COM / NO connector (see smaller
arrows).

Using the hinges, fold the back and front covers by moving as shown in the picture
above.

6

E901 FULL USER MANUAL

3. Connection description

AC 230V L

BOILER CONNECTION*

L

E099011FLRFv2 COM

NO

N

N

OR
AC 230V L

E099011FLRFv2 COM
NO
N

MAX 156((35))AA

Legend:
Boiler – Boiler connection* – Boiler’s contacts for ON/OFF thermostat (according to the boiler’s instructions)
Pump
Valve actuator

Symbols explanation:
L, N – power supply 230V COM, NO – voltage-free output
– fuse

E901 FULL USER MANUAL

7

4. Before you start (first power on) The thermostat is powered by two 1.5V AA alkaline batteries. Insert the batteries into the compartment under the front housing, paying attention to their polarity. The thermostat will start up showing the current software value and then go to the main screen.
1
Reset
PULL OFF THERMOSTAT SLIDE COVER.
2

Reset
INSERT THE BATTERIES, PAYING ATTENTION TO THEIR POLARITY!
3

8

E901 FULL USER MANUAL

Reset
PLACE AND SLIDE THERMOSTAT FRONT HOUSING. THE LCD WILL TURN ON WHEN THE BATTERIES ARE INSERTED.

3

4.1 LCD icon description

7
6 5 4 3 2 1

8 9 10 11 12 13 14
15 16 17 18

1. Program timeline indicator 2. AM/PM 3. Clock 4. Day of the week indicator 5. Settings icon 6. Key lock function 7. Send a signal (pairing)* only E901RF 8. Holiday Mode 9. Low battery indicator

10. Frost Protection Mode 11. Comfort Mode 12. Economic Mode 13. Cooling status 14. Heating status 15. Temperature unit 16. Room / setpoint temperature 17. Temporary override 18. Program number

4.2 Button description

Button
D H M

Function Change the parameter value down Change the parameter value up Set the day of the week Set the hour Set the minutes Comfort temperature Economic temperature / Holiday mode

AUTO AUTO mode / Back button

Programming / Programming type selection
PROG
Confirm button Reset Factory Reset

E901 FULL USER MANUAL

9

5. Time settings In this chapter you will learn how to set the time on the thermostat using the D, H and M buttons. To do this, see the steps below:

1

2

Press any button to highlight the display.
3

Pressing D button set the day.
4
3

Pressing H button set the hour.

Pressing M button set the minutes.

10

E901 FULL USER MANUAL

6. Operation
6.1 Manual mode There are two temperature setpoint levels at our disposal. In manual mode chosen setpoint temperature level is maintained permanently until user changes operation mode or set a different temperature for each level.
– Comfort Mode – in this mode, the thermostat is to maintain a constant day temperature. When the temperature is set manually, e.g. 23°C, the thermostat maintains it until user switches to another operating mode or set a different temperature, e.g. 21°C.
– Economic Mode – in this mode, the thermostat is to maintain the reduced (night) temperature. When the temperature is set manually, e.g. 17°C, the thermostat maintains it until user switches to another mode or set a different temperature, e.g. 19°C.

6.1.1 Comfort mode
In the comfort temperature mode, the thermostat is to maintain a constant day temperature. The comfort temperature level is indicated by sun icon. To set the comfort temperature, see the steps below:

1

2

Press any button to highlight the display.
3

Press button to enter comfort temperature mode. The sun icon should be visible on the display.
4

Using or buttons set new comfort temperature value.
5
3

Confirm by button or wait until the thermostat will approve your choice itself and display the main screen.

The thermostat will return to the main screen and display the actual changed temperature.

E901 FULL USER MANUAL

11

6.1.2 Economic mode
In the economic temperature mode, the thermostat is to maintain a reduced (night) temperature. This is to ensure a more economical operation of the heating system when, for example, you are away from home. The economic temperature level is indicated by the moon icon. To set the economic (night) temperature, see the steps below:

1

2

Press any button to highlight the display.
3

Press button to enter economic temperature mode. The moon icon should be visible on the display.
4

Using or buttons set new economic temperature value.

Confirm by button or wait until the thermostat will approve your choice itself and display the main screen.

5
3

The thermostat will return to the main screen and display the actual changed temperature.

12

E901 FULL USER MANUAL

6.2 AUTO mode – schedule type 1 – AUTO Mode – In the automatic mode, the thermostat maintains the set temperature according to the schedule selected by the user. You can choose from 2 types of schedule to manage the temperature during the week.
Comfort and Economic temperature setpoints works not only in manual mode but also for the first type schedule mode.

First type schedule mode is represented by timeline – 24 hours of a day. Empty,,boxes”means hours where Economic (Moon) setpoint temperature will be maintained, black,,boxes”means hours where Comfort (Sun) setpoint temperature will be maintained.
6.2.1 Default program settings (1-3)
Within first type schedule mode there are 9 programs available. Programs 0 to 3 are factory-defined programs that cannot be changed. In this chapter you will find detailed information on the built-in factory programs (1-3) in the E901. These are pre-programmed time settings for the comfort and economy temperature that can be assigned to a selected day. To set up the program, see the steps below. The black squares on the timeline (see the list of factory programs below) indicate the operating time for the comfort temperature mode, while the absence of them – for the economy temperature mode. Under the chart of each program, there is time (hour) when each mode is active. By default, program 1 is set for each day of the week.

1

2

Press any button to highlight the display.
3

Press PROG button to enter the programming mode.
4

Select the week period using or buttons. Confirm by button.
5

Using or buttons choose program number (0-3). Confirm by button. The thermostat will proceed to
program selection for the next time period.
6

3
The thermostat will return to the main screen saving the set program.

At the bottom of the display you can see the time line, i.e. the program sequence. Comfortable temperature mode
(sun) is set from 6 to 8 and from 4 to 11 p.m.

PLEASE NOTE! Programs should be set for all days of the week.

E901 FULL USER MANUAL

13

6.2.2 Choosing and programming (4-9) user programs In order to program your own schedule its necessary to choose user program (4-9), because only user programs are editable. Then we must draw our own timeline using Sun/Moon buttons. Thermostat will be switching between two setpoint temperatures (Comfort and Economy) which are represented by Sun and Moon icons. Switching time is represented by timeline. See steps below how to programm your own schedule:
Example: below, program 4 will be defined for the MON – FR period with a comfort temperature from 8:00 a.m. to 4:00 p.m. and economic from 0:00 a.m. to 8:00 a.m. and 4:00 p.m. to 0:00 a.m. Programming starts from 0:00 a.m.

1

2

Press any button to highlight the display.
3

Press PROG button to enter the programming mode.
4

Select the week period (MON-FR) using or buttons. Confirm by button.

Using or buttons choose program number 4.

5

6

Use the button several times to set the economic temperature until 8:00 am.

From 8:00 a.m. to 4:00 p.m. set comfort temperature by pressing several times button.

14

E901 FULL USER MANUAL

7

8

Then from 4:00 p.m. to 0:00 a.m. use the button several times to set the economic temperature.
9
3
The thermostat will return to the main screen saving the set program.

Confirm by button.

Please note! Programs 0, 1, 2, 3 are factory set and cannot be edited.
Programs 4 to 9 (user defined) are common to selected periods of the days of the week. This means that if one of the user-defined day programs is changed, the change will also apply to other days in the period.

E901 FULL USER MANUAL

15

6.2.3 Frost Protection program setting
Frost protection mode (program 0) protects heating system against freezing. It is recommended to set this program if you are planning a long winter trip or if you do not heat up for a long time. The thermostat will maintain a constant temperature of 7°C, thus reducing energy consumption to a minimum.

1

2

Press any button to highlight the display.
3

Press PROG button to enter the programming mode.
4

Select the week period using or buttons. Confirm by button.
5
3

Using or buttons choose program number 0. Confirm by button. The thermostat will proceed to
program selection for the next time period.

The thermostat will return to the main screen saving the set program. Snowflake – icon will appear on
the display.

PLEASE NOTE! In the frost protection mode, the temperature setpoint can’t be changed and it is maintained constantly at 7°C.

16

E901 FULL USER MANUAL

6.2.4 Temporary overwrite mode When thermostat is running schedule (automatic mode) we can temporarily override it by new setpoint temperature:

1

2

Press any button to highlight the display.

Use or buttons to set the temperature. Confirm by button.

3

4

3

The display will show the,,hand”symbol.

The overwritten temperature is maintained until the next change forced by schedule.

5
3

Then the,,hand”symbol will disappear from the display and the thermostat will return to the automatic mode.

E901 FULL USER MANUAL

17

6.3 AUTO mode – schedule type 2 – AUTO Mode – In the automatic mode, the thermostat maintains the set temperature according to the schedule selected by the user. You can choose from 2 types of schedule to manage the temperature during the week.
Schedule type 2 is for those who need detailed schedule with more than 2 setpoint temperatures and more accurately timing (schedule type 1 is limited to switching between two setpoint temperatures at full hour switching points).
6.3.1 Switching between AUTO Mode type 1 and 2

1

2

Press any button to highlight the display.
3

5 sec.
Press PROG button for 5 seconds to enter to the schedule programming selection mode.
4
3

Using or buttons choose the second type of schedule programming.

Confirm by button. Thermostat will return to the main screen saving the second type of schedule programming.
The timeline will also disappear.

18

E901 FULL USER MANUAL

6.3.2 Programming method of the AUTO mode – type 2 To set the second type of AUTO mode, please follow steps below:

1

2

Press PROG button to enter the programming mode.
3

Select the week period using or buttons. Confirm by button.
4
3

Using or buttons set the hour for the time period and then after confirmation by button, set the minutes.
Confirm by button.

Use or buttons to set temperature setpoint. Confirm by button. The thermostat will proceed to
program selection for the next time period (a maximum of 6 time periods/switching points can be set).

E901 FULL USER MANUAL

19

6.3.3 Temporary overwrite mode When thermostat is running schedule mode we can temporarily override it by setting new work mode or setpoint temperature:

1

2

Press any button to highlight the display.
3

Using or buttons set temperature setpoint during active AUTO mode.
4

Confirm by button.

The hand icon will be displayed. The temperature will be maintained until the next mode change in the program.

20

E901 FULL USER MANUAL

6.4 Party mode In the party mode, the user can override schedule with comfort setpoint temperature by defined number of hours. To do this, follow the steps below:

1

2

Hold the button for 3 seconds.
3

Use or buttons to select the number of hours.

4

3

Confirm by button.

Comfort setpoint temperature will be maintained for defined number of hours. After that thermostat will go back
to AUTO mode (schedule).

The maximum duration of party mode is 9 hours. The temperature setpoint does not change during this mode. When party mode is enabled, pressing SUN, MOON or AUTO button twice (or 3 times if backlight is OFF) will disable it and thermostat will go back to appropriate mode.

To cancel active party mode (example):

1

2

3

To cancel the function, press any button to turn on backlight and then press 2 times button.

The thermostat will stop party mode and will return to schedule (Auto mode).

E901 FULL USER MANUAL

21

6.5 Holiday mode Holiday mode is a special program temperature setpoint which thermostat will maintain for specified days. During holiday mode thermostat is maintaining frost protection setpoint temperature. How to set HOLIDAY MODE:

1

2

3 sec.

Press any button to highlight the display.
3

Press and hold button for 3 seconds.
4

Use or buttons to select the day period.

Confirm by button.

5

6

3

Use or buttons to set temperature setpoint for selected day period which thermostat will maintain.
Confirm by button. TO STOP HOLIDAY MODE:
1

The thermostat is working in holiday mode. Plane icon is on the display.
2

Press button.
3
3

The thermostat will return to the previous mode.

22

E901 FULL USER MANUAL

Confirm by button.

7. Installer settings

1

2

5 sec.
Press button for 5 seconds.

You are in the installer mode. Use or buttons to move between parameters. Enter the parameter by button. Edit the parameter using or button. Confirm the new
parameter value with the button.

INSTALLER PARAMETERS:

Pxx

Function

Value

P01

Heating/Cooling Selection

1

2

P02

Control method temperature

3

4

5

P03

Display temperature

0,5°C

resolution

0,1°C

P04

Offset temperature

-3.5°C to + 3.5°C

NO

P05

Relay type

NC

24h

P06

Clock format

12h

°C

P07

Temperature Scale

°F

P08

Minimum setpoint 5°C – 34,5°C

P09

Maximum setpoint 5,5°C – 35°C

Description
Cooling Heating SPAN ±0,25°C SPAN ±0,5°C TPI for Underfloor Heating TPI for Radiators TPI for Electrical Heating
This parameter specifies the accuracy of the displayed (measured) temperature.
If the thermostat indicates wrong temperature, you can correct it by ± 3.5°C
Normally Open type of relay
Normally Closed type of relay 24 hour 12 hour Celsius Fahrenheit
Minimum heating / cooling temperature that can be set
Maximum heating / cooling temperature that can be set

Default value
1
0,5°C 0°C NO 24h °C 5°C 35°C

E901 FULL USER MANUAL

23

Pxx

Function

Value

NO

P10

Key sound

YES

NO

P11

PIN Code

PIN

P12

Require a PIN to unlock the keys every time

NO YES

CLR

Clear settings factory reset

NO YES

Description
Off On Disabled Enabled Function disabled Function enabled No action Factory Reset

Default value YES NO YES NO

24

E901 FULL USER MANUAL

8. User settings reset
There is a small hole to the right of the OK button. This is the reset button. Pressing the reset button will restore the default values in the user settings (i.e. time, schedule).

.

Please note:
Do not use a pencil to press the reset button as the graphite build-up on the stylus can short-circuit and damage the thermostat. In environments with very strong electrostatic discharge (+/- 8KV), the
product may not function as under normal conditions. So the device may need to be reset.

9. Clear settings – factory reset
To perform factory reset (which will remove all user/installer settings), use the CLR parameter from installer parameters menu. After confirming the parameter, the thermostat will restore the default settings.

1

2

Press any button to highlight the display.
3

5 sec.
Press button for 5 seconds.
4
3

Use or buttons to move to CLR parameter.

Confirm the new parameter value with the button.

E901 FULL USER MANUAL

25

10. Cleaning and Maintenance The E901 thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or repairs could only be carried out by ENGO Controls or their appointed agents.
11. Technical Informations

Transmitter’s power supply Rating max Output signal Temperature range Display temperature accuracy Control algorithm Communication Dimension [mm]

2 x AA batteries 5 (3) A NO/COM relay 5 – 35°C 0.1°C or 0.5°C ITLC or Hysteresis: ±0.25°C, Hysteresis: ±0.5°C Wired 150 x 84 x 22

84 mm

150 mm

26

E901 FULL USER MANUAL

12. Warranty
ENGO Controls warrants this product to be free from any defects in material or workmanship and to perform as specified for a period of five years from the date of installation. ENGO Controls reserves the sole responsibility for breach of this warranty by repairing or replacing the defective product. This product includes software that matches the distributor’s identification at the time of sale. The manufacturer / distributor provides a guarantee covering all functions and specifics of the product in accordance with this marking. The distributor’s warranty does not cover the correct operation of the functions and features available as a result of a product software update.

E901 FULL USER MANUAL

27

Distributor: QL CONTROLS Sp z o.o. Sp. k. 43-262 Kobielice 4 Rolna St. Poland

Ver. 1 Date of issue: II 2022 Power supply: 2xAA batteries

www.engocontrols.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals