ENGO E901RF Wireless Programmable Thermostat User Guide
- June 9, 2024
- ENGO
Table of Contents
E901RF Wireless Programmable Thermostat
E901RF | Wireless Programmable Thermostat
Wall mounting
1
E901 | Hardwired Programmable Thermostat
Remove the thermostat cover as shown in the picture. If there are batteries
inside, remove them.
2
Ver. 1 Date of issue: I 2022
Quick Guide
Distributor: QL CONTROLS Sp z o.o. Sp. k. 43-262 Kobielice 4 Rolna St. Poland
www.engocontrols.com
Use a screwdriver to push the plastic tabs in as shown in the figure until you
feel resistance, and tilt the front part of the housing.
3
Separate the front part from the back part in the direction shown above.
4
Introduction
E901 & E901RF is a weekly, surface-mounted electronic room thermostat intended
for home use. It has been designed for control of heating devices (e.g. gas,
oil boilers, heat pumps) or cooling devices. It has the function of creating
your own schedules. Thanks to the built-in algorithms, it offers much better
temperature control accuracy than traditional mechanical thermostats. Please
read these instructions carefully before using the device for the first time.
The thermostat should use AA, 1.5V alkaline batteries. Put the batteries in
the battery compartment located under the flap. Rechargeable batteries are not
allowed.
Product Compliance
This product complies with the following EU Directives:
E901: 2014/30/EU, 2014/35/EU, 2011/65/EU
E901RF: 2014/53/EU, 2011/65/EU
868.0 MHz – 868.6 MHz; <13dBm
Please note!
This document is a quick guide for installing and operating the product and
indicates
its most important features and functions.
Safety Information:
Use in accordance with national and EU regulations. Use the device only as
intended, keeping it in a dry condition. The product is for indoor use only.
Installation must
be carried out by a qualified person in accordance with national and EU
regulations.
Installation:
Installation must be performed by a qualified person with appropriate
electrical qualifications, in accordance with the standards and regulations in
force in a given country and in the EU. The manufacturer is not responsible
for non-compliance with
the instructions.
WARNING:
For the entire installation, there may be additional protection requirements,
which the installer is responsible for.
The purpose of this symbol is to indicate that this device should not be
discarded in household waste. For the protection of the environment, human
health and natural resources, disposal should only take place at an
appropriate recycling collection facility for WEEE directive products. For
more information on disposal and recycling of this product please contact
local municipal authorities, disposal services or the original point of
purchase. On sale, exchange or disposal of a device we recommend you reset or
delete any device settings. Internet connected devices should be removed from
any registered online accounts, Mobile or Web Apps, or the online account
should be closed to ensure device data is no longer linked or associated with
your personal details. It is the consumer’s responsibility to remove a device,
close an account, or notify us of any change in ownership to ensure any
association or linkage to personal accounts is removed or updated.
Then fix the back cover to the wall using the supplied mounting screws and the
holes provided (see bigger arrows). Connect the wires to the COM / NO
connector (see smaller arrows).
5
Using the hinges from left, fold the back and front covers by moving as shown
in the picture above until they click into place.
Connection description for wired thermostat E901
AC 230V L
L
E099011FLRFv2 COM
NO
N
N
AC 230V
OR
L
COM
E099011FLRFv2
NO
N
MAX 156((35))AA
BOILER CONNECTION BOILER CONNECTION
E901RX receiver from the wireless kit
Receiver’s switches description: 1. 2.
LEFT SWITCH
ON – Manual mode – receiver ON
OFF – Manual mode – receiver OFF
12 34
RIGHT SWITCH
MANUAL – Receiver works in
manual mode
(according to the left switch)
AUTO – Receiver works in AUTO 4. mode (according to the
thermostat’s command)
LED indications in the receiver
The status of the receiver is indicated by two LEDs. These are LEDs with the
following colors:
1 – green (upper one),
1
2
2 – orange (lower one).
A detailed explanation of the meaning of the LEDs can be found in the table below:
DESCRIPTION
The receiver is connected to the 230V power supply.
The green LED lights up
The receiver can be controlled by thermostat if it is in automatic mode when the right switch is in the AUTO position.
The receiver can be started manually when the right switch is in the MANUAL position.
The green LED flashes
The receiver is in the pairing mode and is looking for a signal from the thermostat (then you must activate the”SYNC”parameter in the thermostat).
The green LED The receiver is disconnected from the 230V power
is off
supply or the left switch is in the OFF position.
The orange LED lights up
In automatic mode, the receiver received a heating / cooling signal from the
thermostat.
The receiver was started in manual mode (left ON switch, right MANUAL switch)
The orange LED flashes
The orange LED is off
The receiver was paired but lost communication with the thermostat due to out
of range or low battery in the thermostat. The receiver starts flashing after
40 minutes of time when it does not receive a signal from the thermostat.
The receiver does not send a heating / cooling signal.
Connection description for wireless thermostat E901RF
AC 230V L
E099011FLRRFFv2
L
L
3V 2 x AA
RREXCRETI5V1E0R COM E901RX
NO
N
N
N
OR
AC 230V L
E099011FLRRFFv2
L
3V 2 x AA
RREXCRETI5V1E0R
COM
E901RX
NO
N
MAX 16 (5) A
N
LCD icon description
7
8 9 10 11 12 13 14
6
5 15
4
3
16
2
17
1
18
1. Program timeline indicator 2. AM/PM 3. Clock 4. Day of the week indicator 5. Settings icon 6. Key lock function 7. Send a signal (pairing) 8. Holiday Mode 9. Low battery indicator
10. Antifrost Mode 11. Comfort Mode 12. Economic Mode 13. Cooling mode – ON 14. Heating mode – OFF 15. Temperature unit 16. Room / setpoint temperature 17. Temporary override 18. Program number
Button description
Button
D H M
Function Change the parameter value down Change the parameter value up Set the day of the week Set the hour Set the minutes Comfort temperature Economic temperature / Holiday mode
AUTO AUTO mode / Back button
PROG Programming / Program selection Confirm function
Reset Factory Reset
Setting Time / Setting Date
– Press D button to set the day. – Press H button to set the hour. – Press M
button to set the minutes.
Manual mode – temperature settings
There are several temperature levels at our disposal. Only one temperature
level is realized 24 hours a day in manual mode. You can set a different
temperature for each level.
– Comfort Mode – in this mode, the thermostat is to maintain a constant day
temperature. When the temperature is set manually, e.g. 23 ° C, the thermostat
maintains it until user switches to another operating mode or set a different
temperature, e.g. 21 ° C. – Economic Mode – in this mode, the thermostat is to
maintain the reduced (night) temperature. When the temperature is set
manually, e.g. 17 ° C, the thermostat maintains it until user switches to
another mode or set a different temperature, e.g. 19 ° C.
The values of these temperatures are taken into account in the automatic mode
(for the first type of schedule -> see next page).
Setting the comfort temperature
Press any button to highlight the screen, then follow the steps below:
1
Press button to enter comfort temperature mode. The sun icon should be visible
on the display.
2
Using or buttons set new comfort temperature value.
3
Confirm by button or wait until the thermostat will approve your choice itself
and display the main screen.
Setting the economic temperature
Press any button to highlight the screen, then follow the steps below:
1
Press button to enter economic temperature mode. The moon icon should be
visible on the display.
2
Using or buttons set new economic temperature value.
3
Confirm by button or wait until the thermostat will approve your choice itself
and display the main screen.
AUTO mode – work according to the schedule
In the automatic mode, the thermostat maintains the set temperature according
to the schedule selected by the user. You can choose from 2 types of schedule
to manage the temperature during the week.
The first type of schedule (factory set with a time line) and its programming
is described below:
– comfort temperature
– economic temperature
There are 9 programs available. Programs 0-3 are factory programs. Programs 4-9 can be defined by user.
Selection of factory (0-3) programs
Press any button to highlight the screen, then follow the steps below:
1
Press PROG button to enter the programming mode.
2
Select the week period using or buttons. Confirm by button.
3
Using or buttons choose program number (0-3). Confirm by button. The
thermostat will proceed to program selection for the next time
period.
Choosing and programming (4-9) user programs
Press any button to highlight the screen, then follow the steps below:
1
Press PROG button to enter the programming mode.
2
Select the week period using or buttons. Confirm by button.
3
Using or buttons choose program number (4-9).
4
Then – each time you press the sun – button or moon button – you move the
timeline one hour and assign a comfortable ( ) or economic ( )
temperature. Confirm by button. PLEASE NOTE! Programs should be set for each
week days.
The second type of schedule and the programming method is described below:
Press any button to highlight the screen, then follow the steps below:
1
5 sec.
Press PROG button for 5 seconds to enter to the schedule programming selection
mode.
2
Using or buttons choose the second type of schedule programming.
3
Confirm by button. Thermostat will return to the main screen saving the second
type of schedule programming. The timeline will also disappear.
4
Press PROG button to enter the programming mode.
5
Select the week period using or buttons. Confirm by button.
6
Using or buttons set the program start and then after confirmation by button,
set the minutes. Confirm by button.
7
Use or buttons to set the temperature. Confirm by button. The thermostat will
proceed to set the next program (a maximum of 6 programs can be set).
PLEASE NOTE! Programs should be set for each week days.
E901RF pairing process with the receiver
PLEASE NOTE! E901RF THERMOSTAT IS ALREADY PAIRED WITH THE RECEIVER!
1
2
3
If you want to re-pair the devices with each other, make sure that the
receiver is disconnected from the power supply, and the switches on it are in
the ON and AUTO positions. Then connect the receiver to the power supply and
wait for the green diode to glow continuously. Next, move the top switch to
the OFF position and back to the ON position with a quick motion. After all,
the green diode will start blinking, which will confirm
that the receiver has entered the pairing mode.
4
5 sec.
Press button for 5 seconds.
5
Use or buttons to select SYNC parameter.
2 6
Confirm by button.
7
Using or buttons choose YES and start the pairing process on a new frequency
by pressing the button.
8
The thermostat started to send a signal to find the receiver (the symbol of
the blinking antenna) and started the countdown with the number 10
(min). The pairing process may take up to 10 minutes.
9
When the green diode on the receiver lights up continuously, the devices have
been paired on a new frequency.
10
The thermostat will display the message,,good”, which means that the devices
are successfully paired with each other.
11
The thermostat will return to the main screen. WARNING! If the green diode on
the receiver has not stopped blinking after 10 minutes, repeat the pairing
process taking into account the distance between devices, obstacles and
interference.
Installer settings
1
5 sec.
To enter installer parameters press and hold button for 5 seconds.
You are in the installer mode. Use or buttons to move between parameters.
Enter the parameter by button. Edit the parameter using
or button. Confirm the new parameter value with the button.
Installer parameters
Pxx Function Value
P01
Heating/Cooling Selection
1 2
P02
Control method temperature
3
4
Description
Default value
Cooling
Heating
SPAN ±0,25°C
SPAN ±0,5°C
TPI for Underfloor Heating 1 TPI for Radiators
5
TPI for Electrical Heating
Display P03 temperature
resolution
0,5°C This parameter specifies the accuracy of the displayed 0,5°C
0,1°C (measured) temperature.
P04
Offset temperature
-3.5°C to + 3.5°C
If the thermostat indicates wrong temperature, you can correct it by ± 3.5°C
0°C
P05 Relay type
NO NC
Normally Open type of relay Normally Closed type of relay
NO
P06 Clock format
24h 12h
24 hour 12 hour
24h
P07
Temperature Scale
°C °F
Celsius Fahrenheit
°C
P08
Minimum setpoint
5°C – 34,5°C
Minimum heating / cooling temperature that can be set
5°C
P09
Maximum setpoint
5,5°C – 35°C
Maximum heating / cooling temperature that can be set
35°C
P10 Key sound
NO YES
NO P11 PIN Code
PIN
Off On
YES
Disabled NO
Enabled
Require a PIN to NO P12 unlock the keys
every time
YES
Function disabled YES
Function enabled
CLR
Clear settings factory reset
NO YES
No action NO
Factory Reset
*Only for E901RF thermostat
Pairing function NO
SYNC with receiver
(SYNC)
YES
Function disabled NO
Function enabled
Technical specification Wired thermostat E901
Thermostat supply Rating max Outputs Temperature range
2 x AA batteries 5 (3) A Voltage-free NO/COM relay 5 – 35°C
Wireless thermostat E901RF (868 MHz)
Thermostat supply Receiver supply Receiver rating max Receiver outputs Temperature range
2 x AA batteries 230 V AC 50 Hz 16 (5) A Voltage-free NO/COM relay 5 – 35°C
References
Read User Manual Online (PDF format)