INTRODUCTION
By-alarm Plus passive infrared detector, 868 MHz radio frequency
connection, surface mounting, power supply with CR17450 3V lithium battery
included, white.
The passive infrared motion detector is a bidirectional radio device.
BATTERIES
The detector is powered by a CR17450 3 V lithium battery. To proceed with
battery replacement, simply open up the body of the device and then replace
the battery, paying attention to the correct insertion, with the polarities
indicated.
When replacing the battery, it is good practice to press the ENROLL push
button to be sure of synchronizing the device with the receiver via radio.
CAUTION! Risk of explosion if the battery is replaced with the incorrect type
INSTALLATION
- Choose a suitable location for installation.
- Undo the screw, open the cover and remove it from the base.
- Undo the screw and remove the electronic board from its seat.
- Open the through holes for the fixing screws.
- Hold the base where it will be fastened and mark the fixing points.
- Fasten the base with the fixing screws.
- Insert the battery with the correct polarity.
- Add the device and enter the QR code in the By-alarm Plus Manager software to configure it.
- Refit the electronic board in its seat.
- Fit the front cover and tighten the fixing screws.
- Carry out the appropriate programming and set the sensitivities.
OPERATION
If someone is moving in the space covered by the detector, the alarm signal is
activated and the
LEDs corresponding to the sensors that detected the movement turn on; in this
case, the red
LED lights to indicate that the alarm signal was sent and has been received by
the control unit.
The detector sensitivity can be set during configuration, depending on the
environment and the position where it is installed. Varying the sensitivity
reduces the range and reduces its ability to detect small heat/temperature
variations.
After transmitting an alarm, it is automatically inhibited for about 3
minutes; a reset is transmitted about 5 s after the alarm has been reset.
LED indications
Red LED on = alarm detected and infrared activated
Anti-tamper
The detector is protected against tampering by:
- a contact on the electronic board;
- an inertial sensor that detects detector position and tilt variations.
CONFIGURATION
Refer to the By-Alarm Plus system installation manual and the By-Alarm Plus Manager software manual for all the details.
INSTALLATION RULES
- Installation and configuration must be carried out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
- Install the device at a height of 2 to 2.4 m.
- The fixing screws are part of the anti-removal device, and so they are essential to ensure that it operates correctly
FRONT VIEW
A: Plastic device cover
B: Red indicator LED
C: Lens
D: Plastic base
E: Seats for cover closing tabs
F: Seats for fixing screws
G: Cover fixing screw
H: Battery positive +
I: Battery negative –
J: Anti-tamper contact
K: Configuration push button
L: Infrared sensor (PIR)
WARNING:
Dispose of batteries in the specific separate collection bins.
- Take great care to avoid drilling into water pipes, gas pipes, electrical conduits, etc. during installation.
- Do not install the detector near the following disturbance sources: reflective surfaces, direct air flows, draughts, fans, windows, steam sources, oil vapor’s, infrared sources, electrical lines, neon lights and objects that can cause temperature variations, such as stoves, refrigerators and ovens (see the INSTALLATION RULES figure).
- Do not use this product in areas with sudden temperature changes.
- Do not obscure the field of view of the detector, not even partially.
- The LEDs must be above the lens.
- Do not touch the sensor surface as doing so may cause it to malfunction. Clean the sensor surface with a soft cloth if necessary
CHARACTERISTICS
-
Power supply: 3 V CR17450 lithium battery included
-
“Low battery” signal voltage: < 2.4 V
-
Consumption:
– 30 µA in standby
– 30 mA max during operation -
Sensor type: Dual digital PIR
-
Detection method: Infrared emission
-
Countable alarm pulses: 1 to 2
-
Minimum signaling duration: 5 s
-
Detection distance: 13 m max
-
Detection angle: 90°
-
Frequency range: 868 MHz
-
RF transmission power: < 25 mW (14dBm)
-
Communication type: bidirectional
-
Modulation: GFSK
-
Average battery life: 3 years
-
Low battery warning: on the keypad and in the control unit
-
1 configuration push button
-
Alarm indicator LED
-
Operating temperature: -10 to +40 °C
-
Relative humidity: ≤ 93% non-condensing
-
Safety class: 2
-
Environment class: II
-
Dimensions (W x H x D): 120 x 60 x 48 mm
-
Weight: 100 g
REGULATORY COMPLIANCE.
RED directive. RoHS directive.
Standards EN 62368-1, EN 50130-4, EN 50130-5, EN 55032, EN 50131-2-6, EN 301
489-3, EN 300 220-2, EN 62479, EN IEC 63000.
Vimar SpA declares that the radio equipment complies with Directive
2014/53/EU. The full text of the EU declaration of conformity is on the
product sheet available on the following website:
www.vimar.com.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead
WEEE – User information
The crossed bin symbol on the appliance or on its packaging indicates that the
product at the end of its life must be collected separately from other waste.
The user must therefore hand the equipment at the end of its life cycle over
to the appropriate municipal center’s for the differentiated collection of
electrical and electronic waste. As an alternative to independent management,
you can deliver the equipment you want to dispose of free of charge to the
distributor when purchasing a new appliance of an equivalent type. You can
also deliver electronic products to be disposed of that are smaller than 25 cm
for free, with no obligation to purchase, to electronics distributors with a
sales area of at least 400 m2
. Proper sorted waste collection for subsequent recycling, processing and
environmentally conscious disposal of the old equipment helps to prevent any
possible negative impact on the environment and human health while promoting
the practice of reusing and/ or recycling materials used in manufacture.
INSTALLATION RULES
COVER DIAGRAMS
Customer Support
Viale Vicenza, 14
36063 Marostica VI – Italy
49401663A0 01 2212www.vimar.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>