AAMP P-BUA-ESCAPE Wiring Harness for Backup Alarm Instruction Manual
- June 9, 2024
- AAMP
Table of Contents
AAMP P-BUA-PROMASTER Wiring Harness for Backup Alarm 2018-2021 RAM Promaster
INTRODUCTION
Wiring harness for backup alarm 2020-2022 Ford Escape
Thank you for purchasing the P-BUA-ESCAPE
WHAT’S INCLUDED
Vehicle Specific Wire Harness (P-BUA-ESCAPE) 6″ Cable Ties Adhesive Cable Tie Mounts 1/2″ Self Tapping Screw
COMPATIBLE ACCESSORIES
97dB Backup Alarm (BUA-97C)
TOOLS REQUIRED
- 7mm Nut-setter
- 10mm Nut-setter
- T-25 Bit
-
2 Phillips Bit
- Knife
- Diagonal Cutters
- Wire Strippers/Crimper’s
- Panel Removal Tool
- Impact Drill
HOW TO OPERATE
STEP 1:
Remove the following cargo space panels
Floor Panel
Left and Right cargo space storage compartments and their contents
Liftgate striker cover (see photo in step 2 for reference)
STEP 2:
Use a T-25 bit to remove the cargo space tie down bolts and a 7mm bit to
remove the cargo space scuff plate trim panel bolts. Then us a panel removal
tool to pry up the clips that are holding the scuff plate in place so it may
be removed.
STEP 3:
Use a panel removal tool to unclip the the passenger (A.) and driver (B.) side
rear quarter panels
STEP 4:
Locate the vehicle’s Green/Brown (A.) wire that is located in the harness
above the rear passenger wheel well (B.)
STEP 5:
Cut the vehicle’s reverse wire in half and splice in/ crimp the backup alarm
harness to the vehicle’s wiring. Then use the supplied 1/2″ self tapping
fastener to ground the ring terminal of the harness to the vehicle chassis.
STEP 6:
Route the backup alarm harness across the backside the cargo space compartment
from the passenger side (A.) to the driver side using the provided cable ties
and cable tie mounts (B.).
STEP 7:
Use a knife to make a small incision in the driver side floor grommet, so that
the backup alarm harness connector may pass through it
STEP 8:
Use an impact drill and 1 0mm nut-setter to install a compatible backup alarm
on the underside of the vehicle. Then plug the backup alarm connector into the
mating connector on the P-BUA-ESACAPE harness and secure any loose wiring.
Note: (2) 10mm TEK screws are provided with the compatible backup alarm
STEP 9:
Test the backup alarm before re-installing all factory panels and load space
compartments.
Note: Be careful not to pinch any wires when re-installing panels.
Phone – 866-931-8021 (option 3)
E-Mail – support@aampglobal.com
AAMP Commercial is a Power Brand of AAMP Global
aampcommercial.com