INTRODUCTION

AAMP P-BUA-PROMASTER Wiring Harness for Backup Alarm 2018-2021 RAM
Promaster

Wiring Harness for Backup Alarm 2018-2021 RAM Promaster

Thank you for purchasing the P-BUA-PROMASTER

WHAT’S INCLUDED

  • Vehicle Specific Wire Harness (P-BUA-PROMASTER)

COMPATIBLE ACCESSORIES

  • 97dB Backup Alarm (BUA-97C)

TOOLS REQUIRED

Tools Required

  1. 10mm Nut-setter
  2. 2 Phillips Bit

  3. Impact Adapter
  4. 17mm Socket
  5. Impact Drill

HOW TO OPERATE

STEP 1: Remove the (7) #2 Phillips screws from the black plastic trim panel that covers the C-pillar cavity and tail lamp connector

STEP 2:

  • Unplug the OEM tail lamp connector
  • Remove the (2) 17mm fasteners that hold the tail lamp assembly in place

STEP 3:

Plug the OEM tail lamp connector into the male end of the P-BUA-PROMASTER harness

STEP 4:
Use an impact drill and 10mm nut-setter to install a compatible backup alarm behind the tail lamp assembly. The backup alarm should be mounted high, so that it clears the tail lamp assembly when it is re-installed.
Note: (2) 10mm TEK screws are provided with the compatible backup alarm
STEP 5:
Plug the backup alarm connector into the mating connector on the P-BUA- PROMASTER harness

STEP 6:

  • Place any excess harness into the C-pillar cavity
  • Re-install the tail lamp assembly
  • Re-install the black plastic trim panel

STEP 7:
Test the backup alarm

Phone866-931-8021 (option 3)