Turn power OFF at circuit breaker
WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death.
Turn off power at circuit breaker or fuse before installing.
Load types and operation
See Section 7 on page 2 of this guide for phase-select instructions.
Note: For dimming MLV fixtures, the maximum lamp wattage is typically
70%- 85% of the transformer’s VA rating. For actual transformer efficiency,
contact the manufacturer.
The total VA rating of the transformer(s) shall not exceed the VA rating of
the dimmer.
IMPORTANT
-
CAUTION: Use only with permanently installed fixtures with dimmable screw-in LED, dimmable self-ballasted compact fluorescent, halogen, or incandescent lamps.
Use only to control the primary side of permanently installed transformer supplied low-voltage lighting, or in combination with incandescent lamps.
To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles, fluorescent
lighting fixtures, non-ballasted or externally ballasted compact fluorescent lamps, motor operated appliances or transformer supplied appliances. -
Neutral is required for all load types.
-
When no “grounding means” exist within the wall box, the NEC® 2011, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wall plate is used.
For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the dimmer and use an appropriate wall plate such as Claro or Satin Colors series wall plates by Lutron. -
Protect rom dust and dirt when painting or spackling the wall.
-
It is normal to feel warm to the touch during operation.
-
Codes: Install in accordance with all local and national electrical codes.
Type 1 action independently mounted operating control. Pollution degree 2, Impulse voltage 4 kV. -
Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity, non-condensing.
Indoor use only. -
Wall plates: Use only Lutron wall plates with these keypads.
The mechanical design of the keypad may not be compatible with non-Lutron wall plates.
Non-Lutron wall plates may not sit flush against the wall.
Claro and Satin Colors wall plates are designed for best color match and clean aesthetic appearance.
Do not paint controls, buttons, or wall plates. -
Cleaning: For disinfecting keypad, please refer to App Note #758 (048758).
Wall boxes: require a U.S. wall box. 3 ` in (89 mm) deep recommended, 2 1 in (57 mm) deep minimum.
Wire the control
Mount the wall plate adapter
Mount the keypad and attach the wall plate
Turn power ON at circuit breaker
Return to factory settings
Note: Returning a keypad to its factory settings will remove the keypad from the system and erase all programming.
- Step 1: Triple tap any button on the keypad (except raise/lower). DO NOT release after third tap.
- Step 2: Keep the button pressed on the third tap until all the status LEDs start to flash slowly (approximately 3 seconds).
- Step 3: Immediately release the button and triple tap the button again. The status LEDs on the keypad will flash quickly.
Bare Ground The keypad has now been returned to its factory settings.
FCC/IC/IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada
license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may
cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co., Inc. could
void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/IC radiation exposure limits set forth for an
uncontrolled environment.
The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna,
which may exceed FCC/IC radio frequency exposure limits.
This Class B digital apparatus complies with Canadian ICES-003.
CUSTOMER SUPPORT
Use our mobile friendly self-paced installation tool:
www.lutron.com/wiringwizard
Find more product information:
www.lutron.com/support
- Videos
- Frequently Asked Questions
Call us:
U.S.A.|Canada|Caribbean 1.844.
LUTRON1 (588.7661) (24/7)
Mexico
+1.888.235.2910
Others
+1.610.282.3800
Documents / Resources
|
LUTRON ARST-H
Dimmer
[pdf] User Manual
0141, JPZ0141, ARST-H, HRST-H, MRST-H, RRST-H, ARST-H Dimmer, ARST-H, Dimmer
---|---
References
- lutron.com/fcc-ic
- Lutron Support Center | Lutron
- How to Install a Dimmer Switch | Dimmer Switch Wiring | Lutron Web Tools
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>