Rittal KX 1500.000 KX Small Enclosures Sheet Steel Instruction Manual

June 9, 2024
RITTAL

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-
logo

Rittal KX 1500.000 KX Small Enclosures Sheet Steel

KX small enclosures, sheet steel

  • KX 1500.000
  • KX 1501.000
  • KX 1502.000
  • KX 1503.000
  • KX 1504.000
  • KX 1505.000
  • KX 1506.000
  • KX 1507.000
  • KX 1508.000
  • KX 1509.000
  • KX 1510.000
  • KX 1511.000
  • KX 1512.000
  • KX 1513.000
  • KX 1514.000
  • KX 1515.000
  • KX 1516.000
  • KX 1517.000
  • KX 1518.000
  • KX 1527.000
  • KX 1528.000
  • KX 1529.000
  • KX 1530.000
  • KX 1531.000
  • KX 1532.000
  • KX 1533.000
  • KX 1535.000
  • KX 1536.000
  • KX 1537.000
  • KX 1538.000
  • KX 1539.000
  • KX 1540.000
  • KX 1541.000
  • KX 1545.000
  • KX 1546.000
  • KX 1547.000
  • KX 1548.000
  • KX 1549.000
  • KX 1550.000
  • KX 1551.000
  • KX 1552.000
  • KX 1553.000
  • KX 1554.000
  • KX 1555.000
  • KX 1556.000
  • KX 1557.000
  • KX 1574.000
  • KX 1575.000
  • KX 1576.000
  • KX 1577.000
  • KX 1578.000
  • KX 1579.000
  • KX 1589.000
  • KX 1610.000
  • KX 1611.000
  • KX 1612.000
  • KX 1613.000
  • KX 1611.100
  • KX 1612.100
  • KX 1613.100

Assembly and operating instructions

Contents

Notes on documentation

The assembly instructions are aimed at all per-sons who have appropriate specialist training to allow them to equip enclosures to conform to standards with electrical, electronic, mecha-nical or pneumatic operating equipment, to place or install at the destination site and to connect ready to operate. The operating instructions are for the operating personnel and appropriately trained specialists for electro-technical and mechanical maintenance.

CE labelling

The declaration of conformity according to DIN EN 62 208 can be downloaded from the Ritual homepage.

Storing the documents

The safety notes and the accompanying note are part of the product. They must be given to the plant operator, who is then responsible for the storage of the documents so that they are readily available when needed.

Symbols used

Please observe the following safety instructions and other notes in this guide:

Other applicable documents

These installation instructions and operating instructions for the described enclosures can be downloaded from www.rittal.com.
We can-not accept any liability for damage associated with failure to observe these instructions.
The instructions for any accessories used also apply.

Normative references

Because the Ritual KX small enclosure, sheet steel conforms to many technical regulations, the enclosure is suitable for the widest-range of markets and application areas.
A current overview for the product is available at www.rittal.com.

Safety instructions

Intended use

These Rittal products are empty enclosures for low-voltage switchgear combinations with maximum rated voltage 1000 V AC or 1500 V DC and instrumentation and control systems intended for use indoors. For special requirements and for outdoor installations, confirmation of suitability must be obtained from Rittal. The load limits specified in the assembly instructions must be observed.
During the development of the KX small enclosure, sheet steel as part of the design study, a risk evaluation according to DIN EN
ISO 12100 was conducted to evaluate and prevent safety-critical items. Because a few residual risks cannot be precluded, the following notes must be observed.
Danger to life and health in case of non-observance of the safety instructions.

Safety instructions

  • The enclosure must be secured against tipping, falling or slipping during transportation, assembly, configuration and dismantling.
  • Beware of cuts and bruising when installing and removing the mounting plate.
  • When working on the KX small enclosure, sheet steel, always use the appropriate personal safety equipment.
  • Take care when unpacking the enclosure, as loose components may cause injury.
  • The health and safety regulations (such as the use of safety blades) must be observed.

Warning against closing movements for mechanical parts of a machine/device
Risk of tipping due to displacement of center of gravity
Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-06The instructions must be read
Installation by specialist electricians
Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-08Installation by specialist mechanics

Device description

Function description and components

As a wall mounting enclosure, the KX small enclosure, sheet steel is suitable for accepting electrical, electronic, mechanical or pneumatic operating equipment and devices in the indoor industrial area.

Scope of supply:

  • 1 KX small enclosure, sheet steel, with cover/door
  • 1 mounting plate (only with EB)
  • 1 dispatch bag (content, see page 18/19)
  • For enclosures with gland plates:
    • 2/4/6/8 gland plates (number of gland plates, see page 18/19)
    • 1/2/3/4 dispatch bags for gland plates (number of gland plates and content)

Please check the scope of supply for completeness.

Labelling

The mounting plate, cover/door, enclosure body and the rating plate have a QR code containing component-specific data.

Identifier Data content
#01 Manufacturing order number
#04 SAP material number
#09 Width
#10 Height
#11 Depth
#19 Pre-assembled condition
#51 Serial number

Example of the enclosure body KX 1500.000: #01|0123456789#04|399339#09|150

10|150#11|120#51|E-19HG-1234567

Scope of delivery

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-10

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-11

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-12

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-13

Assembly and siting

Site requirements

Prior to assembly, ensure that

  • for KX KL and KX EB, the ambient temperature at the installation site is not higher than + 80 °C and not lower than –20 °C.
  • for KX BG, the ambient temperature at the installation site is not higher than +60 °C and not lower than –10 °C.
  • the relative humidity does not exceed 50%at +40 °C.
    Higher humidity levels are permitted at lower temperatures, e.g. 90% relative humidity at + 20 °C.
    Suitable measures should be taken to prevent the formation of condensation.

If particular operating conditions apply, special agreements must be made between Rittal and the user.

Assembly instructions
  • Observe the load capacities specified
    on pages 44 – 49.

  • When installing the enclosures the mounting surfaces must be sufficiently smooth.

  • Observe all specified torque values. Over- or undershooting the tensioning torques specified in these instructions can cause system damage, severe injuries or even death.

  • Avoid any unnecessary openings in the enclosure. Any opening that is not made and sealed carefully can reduce the degree of protection.

  • The equipped mounting plate must be secured in addition to its standard securing for transport.

  • Ensure adequate carrying capacity for wall mounting. The notes in the instructions for the deployed system accessories must also be observed.

KX terminal boxes – Mounting the lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-14

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-
Steel-15

KX terminal boxes – Dismantling the lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-16

KX terminal boxes – Inserting the sealing bungs

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-17

KX terminal boxes – Mounting the gland plates

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-18

KX terminal boxes – Earthing

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-19

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-20

KX terminal boxes – Interior installation

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-21

Rail not included in the supply

  1. nur bei / only for / uniquement pour 1513.000/ 1527.000/1541.000
KX bus enclosures – Mounting the lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-23

KX bus enclosures – Dismantling the lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-24

KX bus enclosures – Mounting the door

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-25

KX bus enclosures – Inserting the sealing bungs

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-26

KX bus enclosures – Earthing

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-28

KX bus enclosures – Interior installation

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-30

Rail not included in the supply

  1. nur bei / only for / uniquement pour 1613.000

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-31 KX E-Box – Mounting the cam lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-32

KX E-Box – Mounting the door

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-33

KX E-Box – Dismantling the cam lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-34

KX E-Box – Changing the cam lock to a l/h door hinge

Risk of potential transfer in the event of a fault

KX E-Box – Fitting the cam lock – l/h door hinge

KX E-Box – Mounting the door – l/h door hinge

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-38

KX E-Box – Inserting the sealing bungs

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-39

E-Box – Installing the mounting plate

Risk of cuts and bruising

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-40

KX E-Box – Earthing

KX E-Box – Interior installation

Rail not included in the supply

KX bus enclosures, mounting plate, cam lock – Mounting the cam lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-60

KX bus enclosures, mounting plate, cam lock – Mounting the door

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-61

KX bus enclosures, mounting plate, cam lock – Dismantling the cam lock

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-62

KX bus enclosures, mounting plate, cam lock – Inserting the sealing bungs

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-63

KX bus enclosures, mounting plate, cam lock – Installing the mounting plate

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-64

KX bus enclosures, mounting plate cam lock – Earthing

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-65

KX bus enclosures, mounting plate cam lock – Interior installation

Rail not included in the supply

Transport

The enclosures must be securely fastened to prevent tipping, falling or slipping during transportation.

  • Ensure that the load is properly secured.
  • Observe the accident prevention regulations.
  • Wear personal safety equipment.

Installation

If there is the possibility of high pressures developing within the enclosure, the enclosure parts could burst.
To counteract all associated dangers, the user must adopt appropriate safety measures.

Earthing and potential equalization

The cover/door and enclosure are prepared for the installation of earthing cables to enable system-compatible earthing where required for configuration purposes. Potential equalization between the enclosure and the mounting plate / gland plate has been incorporated into the design.
The designer must determine the extent to which the automatic contacts are adequate for the earthing system.
To incorporate the cover/door into the safety measure “protection from indirect contact via automatic deactivation”, you will need to connect a separate PE conductor.
All connections must be fitted in accordance with the assembly instructions.

Operation

  • To prevent dust, humidity and air contaminated with pollutants from entering the enclosure, avoid leaving the doors open unnecessarily for a long time.
    The equipped mounting plate must be secured for transport.

  • After working on the enclosure, check that the door is closed properly.

Inspection and maintenance

The maintenance schedule is recommended for all KX small enclosures, sheet steel.

Maintenance interval
Maintenance must be performed at regular intervals depending on use and ambient conditions, at least once annually and documen-ted accordingly.

Nature and extent of the work to be performed:

  • The hinges of the doors are checked for ease of movement and sprayed with a suitable, water-free lubricant.

  • The lock is checked for ease of movement. All moving closure parts are sprayed with a suitable, water-free lubricant.

  • Gaskets in the contact edge area must be replaced completely if damaged. If the gasket is damaged outside the contact edges, the sealing effect is still sufficient as a rule.

  • Common agents such as talcum, Vaseline or wax can be used to prevent damage due to gaskets freezing because of low temperatures. All components and surfaces are examined for external damage.

  • Steel enclosures are also inspected for traces of corrosion. Any damage is repaired as follows:

    • Damage to small areas that affect only a part of the surface (e.g. scratches):
      Lightly sand off the surface at the damaged place and remove all traces of corrosion as well as all contamination.
      Depending on the degree of damage, apply the Rittal touch-up paint either with a paint stick, a brush or a spray can (alter-native: 2K-PUR acrylic paint)

    • Large area damage: Smooth the surface uniformly and clean with white spirit; then paint over the entire surface with Rittal touch-up paint (2K-PUR acrylic paint).

All maintenance work should be carried out by trained experts. The applicable guidelines on maintenance units must be observed.

Storage

When storing the enclosure, ensure that

  • for KX KL and KX EB, the ambient temperature is not higher than +80 °C and not lower than –20 °C.

  • for KX BG, the ambient temperature is not higher than +60 °C and not lower than
    – 10 °C.

  • the relative humidity does not exceed 50%at +40 °C.
    Higher humidity levels are permitted at lower temperatures, e.g. 90% relative humidity at
    + 20 °C. Suitable measures should be taken to prevent the formation of condensation

Technical specifications

Model No.| Dimensions| Volume (ℓ)| Mounting plate design| Load Charge (N)
---|---|---|---|---
Width (mm)| Height (mm)| Depth (mm)| Thickness (mm)| Total| Mounting plate|
1500.000| 150| 150| 120| 2,7| –| 200| 100| 50
1501.000| 300| 150| 120| 5,4| –| 250| 100| 100
1502.000| 200| 200| 120| 4,8| –| 350| 200| 100
1503.000| 300| 200| 120| 7,2| –| 350| 200| 100
1504.000| 400| 200| 120| 9,6| –| 650| 400| 200
1505.000| 500| 200| 120| 12,0| –| 650| 400| 200
1506.000| 600| 200| 120| 14,4| –| 900| 600| 250
1507.000| 300| 300| 120| 10,8| –| 650| 400| 200
1508.000| 400| 300| 120| 14,4| –| 650| 400| 200
1509.000| 500| 300| 120| 18,0| –| 650| 400| 200
1510.000| 600| 300| 120| 21,6| –| 900| 600| 250
1511.000| 400| 400| 120| 19,2| –| 650| 400| 200
1512.000| 600| 400| 120| 28,8| –| 900| 600| 250
1513.000| 800| 400| 120| 38,4| –| 900| 600| 250
1514.000| 150| 150| 80| 1,8| –| 200| 100| 50
1515.000| 300| 150| 80| 3,6| –| 250| 100| 100
1516.000| 200| 200| 80| 3,2| –| 350| 200| 100
1517.000| 300| 200| 80| 4,8| –| 350| 200| 100
1518.000| 400| 200| 80| 6,4| –| 650| 400| 200
1527.000| 800| 200| 120| 19,2| –| 900| 600| 250
1528.000| 200| 150| 80| 2,4| –| 200| 100| 50
1529.000| 200| 150| 120| 3,6| –| 200| 100| 50
1530.000| 300| 150| 120| 5,4| –| 250| 100| 100
1531.000| 300| 200| 120| 7,2| –| 350| 200| 100
1532.000| 400| 200| 120| 9,6| –| 650| 400| 200
1533.000| 500| 200| 120| 12,0| –| 650| 400| 200
1535.000| 300| 300| 120| 10,8| –| 650| 400| 200
1536.000| 400| 300| 120| 14,4| –| 650| 400| 200
1537.000| 500| 300| 120| 18,0| –| 650| 400| 200
1538.000| 600| 300| 120| 21,6| –| 900| 600| 250
1539.000| 400| 400| 120| 19,2| –| 650| 400| 200
1540.000| 600| 400| 120| 28,8| –| 900| 600| 250
1541.000| 800| 400| 120| 38,4| –| 900| 600| 250
1545.000| 150| 300| 80| 3,6| 2,0| 200| 100| 50
1546.000| 200| 200| 80| 3,2| 2,0| 200| 100| 50
1547.000| 200| 400| 80| 6,4| 2,0| 200| 100| 50
1548.000| 150| 300| 120| 5,4| 2,0| 250| 150| 50
1549.000| 200| 200| 120| 4,8| 2,0| 250| 150| 50
1550.000| 200| 400| 120| 9,6| 2,0| 250| 150| 50
1551.000| 150| 150| 80| 1,8| 2,0| 200| 100| 50
1552.000| 200| 300| 80| 4,8| 2,0| 200| 100| 50
Model No.| Dimensions|

Volume (ℓ)

| Mounting plate design| Load Charge (N)
---|---|---|---|---
Width (mm)| Height (mm)| Depth (mm)| Thickness  (mm)| Total| Mounting plate| Door
1553.000| 150| 150| 120| 2,7| 2,0| 200| 100| 50
1554.000| 200| 300| 120| 7,2| 2,0| 250| 150| 50
1555.000| 300| 300| 120| 10,8| 2,0| 250| 150| 50
1556.000| 300| 400| 120| 14,4| 2,0| 250| 150| 50
1557.000| 200| 500| 120| 12,0| 2,0| 250| 150| 50
1574.000| 200| 300| 155| 9,3| 2,0| 200| 100| 50
1575.000| 300| 300| 155| 14,0| 2,0| 250| 150| 50
1576.000| 380| 300| 155| 17,7| 2,0| 250| 150| 50
1577.000| 300| 400| 155| 18,6| 2,0| 250| 150| 50
1578.000| 300| 600| 155| 27,9| 2,0| 300| 200| 50
1579.000| 300| 800| 155| 37,2| 2,0| 325| 200| 75
1589.000| 400| 150| 120| 7,2| –| 350| 100| 200
1610.000| 400| 200| 155| 12,4| –| 200| 150| 25
1611.000| 400| 300| 155| 18,6| –| 200| 150| 25
1612.000| 600| 300| 155| 27,9| –| 250| 200| 50
1613.000| 800| 300| 155| 37,2| –| 250| 200| 75
1611.100| 400| 300| 155| 18,6| 2,0| 200| 150| 25
1612.100| 600| 300| 155| 27,9| 2,0| 250| 200| 50
1613.100| 800| 300| 155| 37,2| 2,0| 250| 200| 75

. Degrees of protection

Model No. Dimensions Degree of protection
Width (mm) Height (mm) Depth (mm)
2) Type (NEMA) 3)
1500.000 150 150
1501.000 300 150
1502.000 200 200
1503.000 300 200
1504.000 400 200
1505.000 500 200
1506.000 600 200
1507.000 300 300
1508.000 400 300
1509.000 500 300
1510.000 600 300
1511.000 400 400
1512.000 600 400
1513.000 800 400
1514.000 150 150
1515.000 300 150
1516.000 200 200
1517.000 300 200
1518.000 400 200
1527.000 800 200
1528.000 200 150
1529.000 200 150
1530.000 300 150
1531.000 300 200
1532.000 400 200
1533.000 500 200
1535.000 300 300
1536.000 400 300
1537.000 500 300
1538.000 600 300
1539.000 400 400
1540.000 600 400
1541.000 800 400
1545.000 150 300
1546.000 200 200
1547.000 200 400
1548.000 150 300
1549.000 200 200
Model No. Dimensions Degree of protection
--- --- ---
Width (mm) Height (mm) Depth (mm)
2) Type (NEMA) 3)
1550.000 200 400
1551.000 150 150
1552.000 200 300
1553.000 150 150
1554.000 200 300
1555.000 300 300
1556.000 300 400
1557.000 200 500
1574.000 200 300
1575.000 300 300
1576.000 380 300
1577.000 300 400
1578.000 300 600
1579.000 300 800
1589.000 400 150
1610.000 400 200
1611.000 400 300
1612.000 600 300
1613.000 800 300
1611.100 400 300
1612.100 600 300
1613.100 800 300

Heat loss

Model No.| Dimensions| | |
---|---|---|---|---
Width (mm)| Height (mm)| Depth (mm)| Watt (W) Watt (W) Watt (W) (ΔT = 20 K)
1500.000| 150| 150| 120| 11| 10| 7
1501.000| 300| 150| 120| 18| 17| 12
1502.000| 200| 200| 120| 17| 14| 11
1503.000| 300| 200| 120| 22| 20| 14
1504.000| 400| 200| 120| 28| 24| 19
1505.000| 500| 200| 120| 34| 30| 23
1506.000| 600| 200| 120| 40| 34| 26
1507.000| 300| 300| 120| 31| 26| 21
1508.000| 400| 300| 120| 39| 33| 26
1509.000| 500| 300| 120| 46| 40| 32
1510.000| 600| 300| 120| 54| 46| 37
1511.000| 400| 400| 120| 48| 42| 34
1512.000| 600| 400| 120| 68| 57| 47
1513.000| 800| 400| 120| 88| 74| 62
1514.000| 150| 150| 80| 9| 8| 6
1515.000| 300| 150| 80| 15| 13| 10
1516.000| 200| 200| 80| 13| 12| 9
1517.000| 300| 200| 80| 19| 17| 13
1518.000| 400| 200| 80| 24| 21| 17
1527.000| 800| 200| 120| 52| 44| 35
1528.000| 200| 150| 80| 11| 10| 8
1529.000| 200| 150| 120| 13| 12| 9
1530.000| 300| 150| 120| 18| 17| 12
1531.000| 300| 200| 120| 22| 20| 14
1532.000| 400| 200| 120| 28| 24| 19
1533.000| 500| 200| 120| 34| 30| 23
1535.000| 300| 300| 120| 31| 26| 21
1536.000| 400| 300| 120| 39| 33| 26
1537.000| 500| 300| 120| 46| 40| 32
1538.000| 600| 300| 120| 54| 46| 37
1539.000| 400| 400| 120| 48| 42| 34
1540.000| 600| 400| 120| 68| 57| 47
1541.000| 800| 400| 120| 88| 74| 62
1545.000| 150| 300| 80| 15| 13| 11
1546.000| 200| 200| 80| 13| 12| 9
1547.000| 200| 400| 80| 24| 21| 18
1548.000| 150| 300| 120| 19| 17| 12
1549.000| 200| 200| 120| 17| 14| 11
Model No.| Dimensions| | |
---|---|---|---|---
Width (mm)| Height (mm)| Depth (mm)| Watt (W) Watt (W) Watt (W) (ΔT = 20 K)
1550.000| 200| 400| 120| 29| 25| 20
1551.000| 150| 150| 80| 9| 8| 6
1552.000| 200| 300| 80| 19| 17| 13
1553.000| 150| 150| 120| 11| 10| 7
1554.000| 200| 300| 120| 23| 20| 15
1555.000| 300| 300| 120| 31| 26| 21
1556.000| 300| 400| 120| 39| 33| 26
1557.000| 200| 500| 120| 35| 31| 24
1574.000| 200| 300| 155| 23| 20| 15
1575.000| 300| 300| 155| 34| 30| 23
1576.000| 380| 300| 155| 41| 36| 28
1577.000| 300| 400| 155| 43| 37| 29
1578.000| 300| 600| 155| 62| 53| 42
1579.000| 300| 800| 155| 79| 68| 54
1589.000| 400| 150| 120| 23| 20| 15
1610.000| 400| 200| 155| 32| 29| 22
1611.000| 400| 300| 155| 43| 38| 29
1612.000| 600| 300| 155| 61| 53| 42
1613.000| 800| 300| 155| 79| 69| 54
1611.100| 400| 300| 155| 43| 38| 29
1612.100| 600| 300| 155| 61| 53| 42
1613.100| 800| 300| 155| 79| 69| 54

Spare parts

A current overview is available at www.rittal.com.

Warranty

The conditions named in the sales and delivery conditions of the associated Rittal agents and subsidiaries apply.

Customer services addresses
Service-HUB Brasilien
Service HUB Brazil
Plateforme de service au Brésil
RITTAL Sistemas Eletromecânicos Ltda.
Av. Cândido Portinari, 1174
Vila Jaguara
05114-001 São Paulo – SP
Phone +55 (11) 3622 2361
Fax +55 (11) 3622 2399
E-mail: service@rittal.com.br
Service-HUB China
Service HUB China
Plateforme de service en Chine
RITTAL Electro-Mechanical Technology Co. Ltd. No.
1658, Minyi Road
Songjiang District
Shanghai, 201612
Phone +86 21 5115 7799-213
Fax +86 21 5115 7788
E-mail: service@rittal.cn

  • Enclosures
  • Power Distribution
  • Climate Control
  • IT Infrastructure
  • Software & Services

You can find the contact details of all Rittal companies throughout the world here.

Rittal-KX-1500-000-KX-Small-Enclosures-Sheet-Steel-74

www.rittal.com/contact
RITTAL GmbH & Co. KG
Auf dem Stuetzelberg · 35745 Herborn · Germany
Phone +49 2772 505-0
E-mail: info@rittal.de · www.rittal.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals