MEAN WELL GST220A Series 220W AC-DC Reliab Green Industrial Adaptor Owner’s Manual

June 14, 2024
MEAN WELL

MEAN WELL GST220A Series 220W AC-DC Reliab Green Industrial Adaptor

MEAN WELL GST220A Series 220W AC-DC Reliab Green Industrial
Adaptor

Features

  • Global certificates
  • Universal AC input/ Full range
  • 3 pole AC inlet IEC320-C14,Class I power unit
  • Built-in active PFC function
  • No load power consumption <0.15W
  • Energy efficiency Level VI
  • Comply with EISA 2007/DoE, NRCan, AU/NZ MEPS, EU ErP and Coe Version 5
  • Protections: Short circuit/ Overload/ Over voltage /Over temperature
  • Fanless design with -30~+70″C working temperature
  • Fully enclosed plastic case
  • LED indicator for power on
  • Various DC plug quick adapter accessory available (Plug kit sold separately, please refer to : https://www.meanwell.com/upload/pdf/DCplug.pdf)
  • 3 years warranty
    Features

Applications

  • Consumer electronic devices
  • Telecommunication devices
  • Office facilities
  • Industrial equipment

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

  • User’s Manual
    QR-Code

  • Video

Description

GST220A is a highly reliable, 220W desktop style single-output green adaptor series. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 94.5% and the extremely low no-load power consumption below 0.1 SW, GST220A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS,EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST220A is certified for the international safety regulations.

Model Encoding

Model Encoding

SPECIFICATION

ORDER NO.| GST220A12-R7B| GST220A15-R7B| GST220A 20R7B| GST220A24-R7B| GST220A36-R7B| GST220A48- R 7B
---|---|---|---|---|---|---
OUTPUT| SAFETY MODEL NO.| GST220A12| GST220A15| GST220A20| GST220A24| GST220A36| GST220A48
DC VOLTAGE Note.2| 12V| 15V| 20V| 24V| 36V| 48V
RATED CURRENT| 15A| 13.4A| 11A| 9.2A| 6.1A| 4.6A
CURRENT RANGE| 0-15A| 0 -13.4A| 0~11A| 0~9.2A| 0 -6.1A| 0 -4.6A
RATED POWER (max.)| 180W| 201W| 220W| 221W| 219.6W| 221W
RIPPLE & NOISE (max.) Note.3| 80mVp–p| 100mVp-p| 120mVp–p| 150mVp–p| 200mVp-p| 200mVp-p
VOLTAG E TOLERANC E Not e . 4| ±5,0%| ± 5.0%| ± 4.0%| ±3.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ± 4.0%| ± 3.0%| ±2.0%| ±2.0%
SETUP, RISE TIME Note.6| 2000ms, 50ms / 230VAC 2000ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC       20ms/ 1151/AC at fulload
INPUT| VOLTAGE RANGE Note.7| 85- 2641/AC 120-3701/DC
FREQUENCY RANGE| 47-63Hz
POWER FACTOR (Typ.)| PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)| 90%| 90%| 92%| 93.5%| 93%| 94.5%
AC CURRENT (Typ.)| 4A/115VAC       2A/230VAC
INRUSH CURRENT (max.)| Cddstart 95AI1151/AC     120AI 2301/AC
LEAKAGE CURRENT(max.)| 0. 75mA / 240VAC
PROTECTION| OVER LOAD| 105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 105 ~ 135% rated output voltage
Protection type : H mode iccup @ 10%load
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT!| WORKING TEMP.| -30 ~ +70 ℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85 ℃ , 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% /’C (0-50’C)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note. 9)| SAFETY STANDARDS Note. 8| UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1 , BS EN/ ,AS/NZS 60950.1 BIS IS13252, KC K60950-1, approved EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) (UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 for GST220A36-R7B)
WITHSTAND VOLTAGE| I /P-0/P:3KVAC I/P-FG2:KVAC 0 /P-FG:SHORT
ISOLATION RESISTANCE| II P-OIP:100MOhms/ S00VDCI 25’CI 70%RH
EMC EMISSION| Parameter| Standard| Test Level  Note
Conducted emission| BS EN/EN50532(CISPR32),FCCPART 15I CISPR22 CANICES-3(B)/NMB-3(B)C, NS13438,GB17625.1
EACTP TC020MSIP Klll32| Class B
Radiatedellission| BS ENIEN55032{CISRP32),FCCPART15 / CISPR22 CANICES3- (B)/NMB3- (B},CNS13438,GB17625.1 EAC TP TC020,MSIP KN32| Class B
Harmonic current| BS EWEN61000-3,G-2B9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY| BS EWEN55035
Parameter| Standard| Test Level /Note
ESD| BSEN/EN61000-4-2| Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibility| BSENIEN61000-4•3| Level 2, 3Vlm
EFT bursts| BSEN/EN61000-4•4| Level 2, 1KV
Surge susceptibility| BSEN/EN61000-45-| Level 3,1KV/Line-Line, 2KV/Une-FG
Conducted susceptibility| BSENIEN61000-4-6| Level 2, 3V
Magnetic field immunity| BSENI EN61000-4-8| Level 2, 3A/m
Voltage dips , interruption| BSENIEN61000-4-11| > . 95% dip 0 5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
OTHERS| MTBF| 2006.1K hrs min. Telcordia SR-332 (Bellcore) ; 209.4K hrs min. MIL-HDBK-217F (25 ) ℃
DIMENSION| 2108546mm (LWH)
PACKING| 1.1Kg; 12pcs/14.2Kg/0.81CUFT
CONNECTOR| PLUG| Other type available by customer requested
CABLE| Other type available by customer requested
NOTE|

  1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient.
  2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
  3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1 f & 47 tf capac.
  4. Tolerance: includes set up tolerance, line regulation, load regulation.
  5. Line regulation is measured from low line to high line at rated load.
  6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. Derating may be needed under low input voltage. Please check the derating curve for more details.
  8. The demand for Malaysia safety is processed with the order no. GST220A □ -SIRIM by request. Please contact MEAN WELL for details.
  9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    (as available on http://www.meanwell.com)
    ∗ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Derating Curve

  • AMBIENT TEMPERATURE (ºC )
    Derating Curve

Static Characteristics

  • INPUT VOLTAGE (VAC) 60Hz
    Static Characteristics

Mechanical Specification

  • Case No. 961A Unit:mm
    Mechanical Specification

DC Output Plug

◎ Standard plug: R7B

R7B Pin Assignment

DC Output Plug| | PIN NO.| OUTPUT
1| +Vo
2| -Vo
3| -Vo
4| +Vo

◎ DC plug changeable through:

  1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
  2. Quick adapter accessory (sold separately without MOQ)
    Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf

Example quick adapter accessory:
Accessory

◎ Optional DC plug: (Available in customized cable or quick adapter)

Tuning Fork Style

| Type No.| A| B| C| Quick Adapter Accessory
---|---|---|---|---|---
OD| ID| L
Optional DC Plug| P1J| 5.5| 2.1| 11.0| Available for 48V

(Current rating: 7.5A max.)

P1M| 5.5| 2.5| 11.0

Min. DIN 4 Pin with Lock (female)

| Type No.| Pin Assignment| None
PIN No.| Output
Optional DC Plug| R7BF| 1| +Vo
2| -Vo
3| -Vo
4| +Vo

DIN 5 Pin (male)

| Type No.| Pin Assignment| None
PIN No.| Output
Optional DC Plug| R1B| 1| -Vo
2| -Vo
3| +Vo
4| -Vo
5| +Vo

NEUTRIK XLR NC4FX equivalent

| Type No.| Pin Assignment| None
PIN No.| Output
Optional DC Plug| MIC4| 1| +Vo
2| +Vo
3| -Vo
4| -Vo

MOLEX 39-01-2060 (4.2mm) equivalent

| Type No.| Pin Assignment| None
PIN No.| Output

FG not connected to output connector
Optional DC Plug

| C6P| 1| +Vo
2| +Vo
3| +Vo
4| -Vo
5| -Vo
6| -Vo

AMP 1-480702-0 (6.35mm) equivalent

| Type No.| Pin Assignment| Quick Adapter Accessory
PIN No.| Output

FG not connected to output connector
Optional DC Plug

| C4P| 1| +Vo| None
2| +Vo
3| -Vo
4| -Vo

Stripped and tinned leads

| Type No.| Pin Assignment| None
PIN No.| Output
Length of Land L1 by request
(MW ’s standard length, L: mm, L1: mm)
( NOTE : The wire color is for reference only, please refer to the actual product)
Optional DC Plug| by customer| 1| +Vo
2| -Vo

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Symbols

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals