KSR LIGHTING KSR98123 Navara HB Remote Microwave Sensor Installation Guide

June 9, 2024
KSR LIGHTING

KSR98123 Navara HB Remote Microwave Sensor
Installation Guide

Read these instructions before commencing installation. Please give these instructions to the owner/occupier after installation to retain for future reference/maintenance.
IP65 220-240VAC~50/60 Hz
These fittings are Class II and do not require to be Earthed

Important Information

It is recommended that these controls are installed and fitted by a qualified electrician ensuring the installation complies with current IEE wiring regulations & local building control. These products are designed for connection to a 220-240V-50/60Hz supply.
Any faulty, broken or damaged sensors should be replaced immediately.
KSR will not accept responsibility for any claims arising from a poor installation.
Please Note: The limited warranty shall be deemed null and void in the following circumstances: Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature, humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of the products or parts.
Important User Advice
Always switch off mains supply before fitting or servicing.
Do not use Merger or similar high voltage instruments. Due to the fact this control contains electronic components that maybe damaged by high test voltages, they must be disconnected from the circuit before testing.
To prevent damage to the control, do not mix with conventional magnetic ballasts on the same electrical circuit. At the end of life the luminaire is classed as WEEE under directive 2014/30/EU and should be disposed of in accordance with local legislation.

Installation Procedure

KSR recommends that you familiarize yourself with the installation. Once you are completely satisfied:
Safely isolate the mains supply.
Locate the area’s suitable to install this control on the luminaire (See KSR98120, KSR98121 or KSR98122 for further information).
Avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid metal objects in the line of sight.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc
Install the sensor on to the luminaire.
Connect the wiring as per the instructions supplied with the highboy. If you do not have these please contact KSR for a copy or download from www.ksrlighting.com
See overleaf for setting options, never remove the cover or adjust the dip switches without safely isolating the mains supply.
Switch on the power and test.

KSR LIGHTING KSR98123 Navara HB Remote Microwave Sensor -
Dimension

Navara HB IP65 Dimming Microwave Sensor
Available finish:
Black

Sensor Specification:

Mains Input – 220-240VAC 50/60Hz
Lux Control – 2, 10, 50 or 2000 Lux
Hold Time – 5 s, 30 s, 90 s, 3 min, 5 min, 10 min, 20 min or 30 min
Rated Load – LED 1000 W / Halogen 2000 W
Detection Area – 360°
Detection Range – 50% or 100%
Detection Radius – 10m Max (<24°C)
Stand-by Period – Os, 10 s, 1 min, 5 min, 10 min, 30 min, 60 min or ∞
Stand-by Dimming Level – 10%, 20%, 30% or 50%
Parasitic Power – 0.5 W
Installation Height – 4 m-15 m
Detection Speed : 0.6-1.5m/s
Working Temperature: -20-+40°C

Wiring

Read these instructions before commencing installation. Please give these instructions to the owner/occupier after installation to retain for future reference/maintenance.
IP65 220-240 W 50/60Hz
These fittings are Class II and do not require to be Earthed
Important Information
It is recommended that these controls are installed and fitted by a qualified electrician ensuring the installation complies with current IEE wiring regulations & local building control. These products are designed for connection to a 220-240V-50/60Hz supply.
Any faulty, broken or damaged sensors should be replaced immediately.
KSR will not accept responsibility for any claims arising from a poor installation.
Please Note: The limited warranty shall be deemed null and void in the following circumstances:
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature, humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of the products or parts.

KSR LIGHTING KSR98123 Navara HB Remote Microwave Sensor -
Wiring

Note
When Sensor is being used as on/off only ensure the 1-10 v dimming pair (red and white) are terminated separately as to avoid control issues.

Sensor Set Up Guide

Read these instructions before commencing installation. Please give these instructions to the owner/occupier after installation to retain for future reference/maintained.
IP65 220-240V-50/60Hz Instructions Please note mains must be isolated before sensor is opened and set, this is due to the dip switches being in close proximity of a high voltage circuit

  1. To access Dip Switches remove cap by releasing screw on top of Sensor casing (screw driver required)
  2. With fixing screw removed twist cover anti-clockwise until the cover is free from the main body
  3. Referring to dipswitch table label on sensor housing and shown below set dip switches to desired setting and test
  4. Once you are satisfied with your settings screw cover clockwise onto main sensor body and fix in place with screw to secure.KSR LIGHTING KSR98123 Navara HB Remote Microwave Sensor - Sensor Set Up

Microwave sensors will detect movement through certain materials, if this occurs reduce the detection area until any nuisance triggering stops.

  1. Detection Range
    Detection area can be reduced by selecting the combination on the Dip Switches, following the guide as shown here. 1|
    ---|---
    | 100%
    | 50%
  2. Hold Time
    Hold time means the time period you would like the light to remain on once the sensor has detected movement. 2| 3| 4|
    ---|---|---|---
    | | | 5 s
    | | | 30 s
    | | | 90 s
    | | | 3 min
    | | | 5 min
    | | | 10 min
    | | | 20 min
    | | | 30 min
  3. Standby Period
    The standby period is the time the sensor stays on for when the initial hold time has lapsed, this is used when the user wants the fitting to dim down to a reduced level for a set period of time after the initial hold time. If this is not required set dipswitches to 0 s and the sensor will turn off after the hold time has lapsed

5| 6| 7|
---|---|---|---
| | | 10 s
| | | 1 min
| | | 5 min
| | | 10 min
| | | 30 min
| | | 60 min
| | | + ∞
| | | 0 s
4. Standby Dim Level
This is the level the sensor will dim down to after the initial hold time has lapsed. This is set in conjunction with switches 5,6 and 7. 8| 9|
---|---|---
| | 10%
| | 20%
| | 30%
| | 50%
5. Daylight Sensor
The daylight sensor can be set to bring the light ‘on’ at specific daylight levels. To have the sensor function in daylight set the Dip Switches to 2000 lux. 10| 11| 12|
---|---|---|---
| | | 2000 lux
| | | 50 lux
| | | 10 lux
| | | 2 lux

KSR Lighting Ltd
Unit E Hazleton Interchange,
Lakesmere Road, Homdean,
Hampshire, P08 9JU
KSR Lighting After sales: 023 92 674343
E-mail: [email protected]
Drg No. KSR98123-IS-C

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KSR LIGHTING User Manuals

Related Manuals